Tomographic Imager Combining Emission Computed Tomography With Nuclear Magnetic Resonance
Radiology · 21 CFR 892.1200
Imager that generates both both magnetic resonance (mr) and positron emission tomography (pet) images and provides registration and fusion of these images. Pet and mr images can be acquired either simultaneously or sequentially. Anatomical mr images are used for pet attenuation correction.
Recent MDR events
13 adverse event reports on file
- NAApr 15, 2026InjuryGe Medical Systems, Llc2183553-2026-00002
- SIGNA PET/MROct 1, 2021InjuryGe Medical Systems, Llc2183553-2021-00010
- INGENUITY TF PET/MROct 19, 2020MalfunctionPhilips Medical Systems Nederland B.v.3015777306-2020-00017
- SIGNA PET/MRNov 14, 2018InjuryGe Medical Systems, Llc2183553-2018-00017
- SIGNA PET/MRApr 27, 2017InjuryGe Medical Systems, Llc2183553-2017-00006
- SIGNA PETMRJan 9, 2017InjuryGe Medical Systems, Llc2183553-2017-00001
- 3.0T PET/MRJul 24, 2015InjuryGe Medical Systems, Llc2183553-2015-00017
- INGENUITY TF PET/MRApr 14, 2015MalfunctionPhilips Medical Systems(cleveland), Inc.1525965-2015-00101
- BIOGRAPH MMRAug 11, 2014InjurySiemens Healthcare2240869-2014-06205
- INGENUITY TF PET/MRMar 3, 2014Philips Medical Systems(cleveland), Inc.1525965-2014-00038
Event type breakdown
Recalls
9 recall events for this product code
- Siemens Medical Solutions USA, IncOpen, ClassifiedSep 30, 2025
Biograph mMR. Model Number: 10433372.
There is a potential for an ice blockage to form or currently exist within the magnet venting system. In the event of a quench, helium gas may be unable to escape through the designed venting paths, leading to a pressure build-up within the helium containment system. This pressure build-up could ultimately rupture the helium containment system, potentially resulting in a helium leak into the scanning room.
Z-2654-2025 · View FDA record ↗ - GE Medical Systems, LLCOpen, ClassifiedAug 2, 2024
SIGNA PET/MR, with affected software versions: MP24.0, MP26.0, MP26.1, MR30.0, MR30.1; Tomographic imager combining emission computed tomography with nuclear m
GE HealthCare has become aware that for certain MR systems, the system predicted B1+RMS value can exceed the B1+RMS user prescribed limit when scanning in Low SAR Mode and the following two conditions are met: 1. 2D FSE T2 FLAIR OR T2 FLAIR Propeller imaging sequence is selected, AND 2. the Optimized T2 FLAIR sequence option is turned off OR not included in the MR configuration. If this occurs, it can result in overheating of an MR conditional implant.
Z-2466-2024 · View FDA record ↗ - GE Healthcare, LLCOpen, ClassifiedJul 12, 2021
SIGNA PET/MR, Tomographic Imager Combining Emission Computed Tomography With Nuclear Magnetic Resonance
GE Healthcare has recently become aware of an issue on the affected products listed below where the "Patient Orientation" button may inadvertently be clicked when intending to click on the "Save RX" button. This changes the prescribed patient orientation on the system prior to running the initial 3-Plane Localizer Scan (See Figure 1 for reference to buttons.) Selecting and saving a patient orientation that does not match the patient's actual position may result in incorrectly annotated and/or flipped images.
Z-2057-2021 · View FDA record ↗ - GE HealthcareTerminatedNov 10, 2015
GE Healthcare, SIGNA PET/MR 3.0T.
When performing head or neck scans, the currently displayed SAR values could be lower than the actual SAR in the head as predicted by SAR modeling. The predicted HEAD SAR value from the modeling suggests the actual SAR in the head could exceed IEC60601-2-33 limit of 3.2 W/kg for some scans.
Z-0260-2016 · View FDA record ↗ - Philips Medical Systems (Cleveland) IncTerminatedAug 31, 2015
Ingenuity TF PET/MR, Diagnostic Imaging System , Philips Medical Systems
Philips Healthcare has become aware of a problem in which the Ingenuity TF PET/MR PET Reconstruction Server (PRS) database may lock up after an MR acquisition is completed and before a PET acquisition is begun, even though no actual database lockup issue has been reported in the field-installed Ingenuity TF PET/MR systems.
Z-2491-2015 · View FDA record ↗ - Philips Medical Systems (Cleveland) IncTerminatedJun 11, 2015
Ingenuity PET/MR (Uninterruptible Power Supply (UPS) accessory devices) Computed Tomography X-ray systems and Diagnostic Imaging systems.
The firm was notified that the failure of the UPS accessory devices used in conjunction with Computed Tomography X-ray systems and Diagnostic Imaging systems. may result in battery acid leakage, overheating and/or emission of fumes.
Z-1780-2015 · View FDA record ↗ - Philips Medical Systems (Cleveland) IncTerminatedMay 22, 2012
Ingenuity TF PET/MRI System v.3.7.1, 510(k) #K103483, Model #882380.
Software errors. A number of non-conformances were identified and corrected by Philips Medical for their Ingenuity TF PET/MRI Systems running software version 3.7.1. The firm states that these non-conformances stemmed from software and/or documentation errors, and that software corrections are being performed in order to 'improve the overall quality and functionality of the Ingenuity TF CT/MRI S
Z-1646-2012 · View FDA record ↗ - GE Healthcare, LLCTerminatedUnknown
Tomographic Imager Combining Emission Computed Tomography With Nuclear Magnetic Resonance - Product Usage: The combined system maintains independent functionali
Potential electrical arc flash within the Power Gradient & RF (PGR) Cabinet.
Z-0131-2021 · View FDA record ↗ - GE Healthcare, LLCOpen, ClassifiedUnknown
GE Healthcare MR superconducting magnets, a component of GE Healthcare SIGNA PET/MR System, tomographic imager combining emission computed tomography with nucle
The magnetic resonance systems could potentially have a cryogen ventilation system that does not meet the venting requirements.
Z-0595-2022 · View FDA record ↗
Registered firms
35 firms currently registered for this product code
Ge Healthcare Manufacturing Llc
FLORENCE, SC, US
Elekta Solutions Ab
STOCKHOLM, SE
Siemens Healthineers Ag
ERLANGEN Bavaria, DE
Anholt Technologies Inc.
Avondale, PA, US
Ge Healthcare (tianjin) Company Limited
Tianjin, CN
Siemens Shenzhen Magnetic Resonance Ltd.
SHENZHEN Guangdong, CN
United Imaging Healthcare North America, Inc
Houston, TX, US
Ge Healthcare Manufacturing Llc
Florence, SC, US
Ge Medical Systems, Llc
WAUKESHA, WI, US
Ge Healthcare Coils
AURORA, OH, US
510(k) clearances
15 clearances for this product code
- Cubresa, Inc.Jul 17, 2026
K253963 · Cubresa BrainPET
- Siemens Healthineers AGJan 15, 2026
K253023 · BIOGRAPH One
- Shanghai United Imaging Healthcare Co., Ltd.May 24, 2024
K234154 · uPMR 790
- Shanghai United Imaging Healthcare Co., Ltd.Nov 14, 2022
K222540 · uPMR 790
- Ge Medical Systems, LLCJan 20, 2022
K213709 · SIGNA PET/MR
- Siemens Medical Solutions USA, Inc.May 11, 2020
K200213 · Biograph mMR with syngo MR E11P-AP01 system software
- Shanghai United Imaging Healthcare Co., Ltd.Nov 20, 2019
K192672 · uPMR 790
- Shanghai United Imaging Healthcare Co., Ltd.Feb 27, 2019
K183014 · uPMR 790