System, X-ray, Extraoral Source, Digital
Dental · 21 CFR 872.1800
Recent MDR events
65 adverse event reports on file
- Schick 3.0 USB interfaceJul 28, 2026MalfunctionDentsply Llc York Smile Way2424472-2026-05830
- SYSTEM, X-RAY, EXTRAORAL SOURCE, DIGITALApr 16, 2026Malfunction24895461
- GALILEOSMay 28, 2025InjurySirona Dental Systems Gmbh9614977-2025-00012
- INTRAORAL X-RAYSJul 21, 2023InjuryUnknownMW5119906
- CONE BEAM CTDec 14, 2021InjuryTrophyMW5106062
- CONE BEAM 3D IMAGEAug 13, 2019InjuryUnknownMW5089055
- Unnamed deviceApr 24, 2019MalfunctionCOR19000236-000
- Unnamed deviceMar 27, 2019MalfunctionCOR19000165-000
- Unnamed deviceFeb 21, 2019MalfunctionCOR19000104-000
- Unnamed deviceFeb 14, 2019MalfunctionCOR19000100-000
Event type breakdown
Recalls
9 recall events for this product code
- Villa Radiology Systems LLCTerminatedNov 6, 2015
Villa Sistemi Rotograph EVO 3D X-ray
It has been discovered that due to lack of information accompanying documents the product fails to comply with 21CfR 1020.33(c),1020.33(d),1020.33(g),and 1020.330).
Z-0128-2016 · View FDA record ↗ - Carestream Health, Inc.TerminatedApr 3, 2015
CS 8100, CATALOG # (s): 5303045, 5311129, 5303060, 5303110
Units device head descended unexpectedly
Z-1377-2015 · View FDA record ↗ - Carestream Health, Inc.TerminatedApr 3, 2015
CS 8100 3D, CATALOG # (s): 5311162, 5311188.
Units device head descended unexpectedly
Z-1378-2015 · View FDA record ↗ - Midmark Corp dba Progeny IncTerminatedJan 9, 2014
The Vantage Digital Panoramic System delivers high-value features standard on every system: - Five pre-programmed exam settings, including bitewing, minimize ex
An error was identified in the Real Time Controller (RTC) firmware versions 3.0, 3.1, 3.2, and 3.3 used in Vantage Panoramic X-Ray systems. The error may cause the column of the Vantage Panoramic X-Ray unit to continue moving vertically despite the release of the movement control button (i.e. failure to stop").
Z-0651-2014 · View FDA record ↗ - Gendex Dental SystemsTerminatedJul 17, 2009
Gendex VixWin Platinum Imaging Software, Versions 1.0, 1.1 and 1.2; Gendex Dental Systems, 901 West Oakton Street, Des Plaines, IL 60018.
There is a compatibility issue when the VixWin Platinum versions 1.0/1.1/1.2 software is used in conjunction with Easy Dental, PracticeWorks, EagleSoft and SoftDent practice management software, resulting in patient files that may contain images that are mixed between patients.
Z-1548-2009 · View FDA record ↗ - Imaging Sciences International, LLCTerminatedMay 22, 2009
Gendex CB-500, 3D Dental Imaging Systems, Model Number G1-15-1-0. This product is manufactured by Imaging Sciences International for Gendex Corporation.
faulty calibration
Z-1265-2009 · View FDA record ↗ - Imaging Sciences Intl IncTerminatedSep 1, 2008
i-CAT 17-19 Cone Beam 3D Dental Imaging System. This product is also sold under a private label as KaVo 3D eXam
Incorrect scatter information in the manual.
Z-1646-2008 · View FDA record ↗ - Midmark Corp dba Progeny IncTerminatedUnknown
Vantage Panoramic X-Ray System used to perform dental and orthodontic radiological imaging
Failure of the primary collimator may result in unintentional movement of the device. The unintentional movement will not result in the generation of an error message.
Z-0651-2016 · View FDA record ↗ - KaVo Dental Technologies LLCTerminatedUnknown
DEXIS Titanium Intraoral Sensor
The sensor's look up calibration files were incorrectly programmed during manufacturing, which can result in the reduction of image quality.
Z-1387-2019 · View FDA record ↗
Registered firms
183 firms currently registered for this product code
Hdx Will Corp.
Heungdeok-gu, Cheongju-si, Chungcheongbuk-do Chungbuk, KR
Rayence Co., Ltd.
Hwaseong-si Gyeonggi, KR
Fussen Technology Co., Ltd
Shenzhen Guangdong, CN
J. Morita Mfg. Corp., Tottori Factory
Kurayoshi Tottori, JP
Cleartooth Electronics, Inc.
Boulder, CO, US
Dexcowin Co., Ltd.
Seoul, KR
Iray Group
Shanghai, CN
Trident Srl
Castenedolo Brescia, IT
Carestream Healthcare International Company, Ltd
Shanghai, CN
Palodex Group Oy
Tuusula Uusimaa, FI
Dentsply Llc
York, PA, US
Carestream Dental Technology Topco Limited
London London, City of, GB
Oketz Logistics Llc
Coral Gables, FL, US
Genoray Co., Ltd.
Seongnam-si Gyeonggi, KR
Carestream Dental Llc
Atlanta, GA, US
Genoray America Inc.
Anaheim, CA, US
Kashmir Surgical Works
AMBALA Haryana, IN
Vatech Co., Ltd.
Hwaseong-si Gyeonggi, KR
Qpix Solutions, Inc.
Morrisville, NC, US
Beyes Dental Inc
Toronto Ontario, CA
De Gotzen S.r.l.
FAGNANO OLONA Varese, IT
510(k) clearances
206 clearances for this product code
- Sota Cloud Corp.Mar 3, 2026
K251793 · SOTA Cloud Smart Sensor (1.5)
- Qpix Solutions, Inc.Nov 10, 2025
K252570 · EzSensor HD, EzSensor UHD
- Dexcowin Global, Inc.Oct 24, 2025
K250687 · Cocoon Solo (DX-7020s)
- Dentimax, Inc.Sep 24, 2025
K251206 · Digital X-Ray DentiMax Pro Imaging System
- VATECH Co., Ltd.Oct 25, 2024
K240040 · VistaPano S Ceph 2.0 (VistaPano S Ceph); VistaPano S 2.0 (VistaPano S); ProVecta S-Pan Ceph 2.0 (ProVecta S-Pan Ceph); ProVecta S-Pan 2.0 (ProVecta S-Pan)
- Qpix Solutions, Inc.Oct 11, 2024
K242778 · X Sensor (Model: IOS-A15IF, HDI-15DGF)
- Zinnovi, Inc.Jul 5, 2024
K241649 · DUO1 and DUO2
- Ray Co., Ltd.Apr 18, 2024
K232325 · RAYSCAN a-Expert