Subsystem, Water Purification
Gastroenterology, Urology · 21 CFR 876.5665
Recent MDR events
696 adverse event reports on file
- Ultrafilter HechingenJul 30, 2026MalfunctionVantive Us Healthcare Llc9611369-2026-00103
- Ultrafilter HechingenJul 30, 2026MalfunctionVantive Us Healthcare Llc9611369-2026-00104
- Subsystem, Water PurificationJul 27, 2026MalfunctionVantive Us Healthcare Llc9611369-2026-00102
- ULTRAFILTER HECHINGENJul 21, 2026MalfunctionVantive Us Healthcare Llc9611369-2026-00098
- ULTRAFILTER HECHINGENJul 14, 2026MalfunctionVantive Us Healthcare Llc9611369-2026-00092
- AQUABPLUS 2500 B2 2000Jun 16, 2026MalfunctionVivonic Gmbh3010850471-2026-00007
- ULTRAFILTER HECHINGENApr 23, 2026MalfunctionVantive Us Healthcare Llc9611369-2026-00049
- AQUABPLUS 2500 B2 2000Apr 16, 2026MalfunctionVivonic Gmbh3010850471-2026-00006
- NEPHROSApr 3, 2026MalfunctionNephros3003337893-2026-00001
- AQUABPLUS 2500 B2 2000Mar 18, 2026MalfunctionVivonic Gmbh3010850471-2026-00005
Event type breakdown
Recalls
15 recall events for this product code
- Fresenius Medical Care Holdings, Inc.Open, ClassifiedJun 13, 2024
US AquaA 900H-Typ USA-3 x 208v-Intended for the purification of water to be used for hemodialysis
Concentrate Flow was exceeding the maximum 19.9 bar set point. The standard default set point range is between 4 and 18.Error message (F020104, "concentrate pressure alarm limit exceeded") concentrate pressure is too high and stops the dialysis water supply.
Z-2141-2024 · View FDA record ↗ - Outset Medical, Inc.Open, ClassifiedApr 7, 2023
Outset Tablo
An observed trend of high conductivity dialysate alarms in a hemodialysis system as a result of introducing a software tool into the manufacturing process.
Z-1351-2023 · View FDA record ↗ - Fresenius Medical Care Holdings, Inc.Open, ClassifiedSep 19, 2022
AquaC UNO H [120V, 60Hz, 1000VA, US-Version - a reverse osmosis unit intended for use with hemodialysis systems.
Internal ethemet cables are missing one or both ferrite cores therefore the electromagnetic compatibility of the device is not ensured
Z-1769-2022 · View FDA record ↗ - Fresenius Medical Care Holdings, Inc.Open, ClassifiedSep 19, 2022
AquaC UNO H [120V, 60Hz, 1700VA, US-Version- a reverse osmosis unit intended for use with hemodialysis systems.
Internal ethemet cables are missing one or both ferrite cores therefore the electromagnetic compatibility of the device is not ensured
Z-1770-2022 · View FDA record ↗ - Fresenius Medical Care Holdings, Inc.Open, ClassifiedJul 25, 2022
AquaC UNO H [120V, 60Hz, 1700VA,
Internal ethernet cable may be misaligned, the cable jacket (insulation) could become compromised due to high temperature and result in the internal ethernet cable conducting electrical current to the ethernet port on the outside of the device), potentially harming service technicians and/or other authorized operators. If the ethernet port on the device is touched or manipulated, there is a risk of electrical shock
Z-1463-2022 · View FDA record ↗ - Fresenius Medical Care Holdings, Inc.Open, ClassifiedJul 25, 2022
AquaC UNO H [120V, 60Hz, 1000VA,
Internal ethernet cable may be misaligned, the cable jacket (insulation) could become compromised due to high temperature and result in the internal ethernet cable conducting electrical current to the ethernet port on the outside of the device), potentially harming service technicians and/or other authorized operators. If the ethernet port on the device is touched or manipulated, there is a risk of electrical shock
Z-1464-2022 · View FDA record ↗ - Mar Cor PurificationTerminatedMay 6, 2014
Mar Cor Purification, Central Water Platform (CWP), 102, 104 and 106.
Mar Cor Purification manufactured Central Water Plant (CWP) reverse osmosis system, models 102, 104 and 106. This correction has been initiated due to a potential situation with a specific lot of the water inlet solenoid valve. The potential exists that the water inlet solenoid valve could cease to function. If this occurs, CWP will stop producing reverse osmosis water.
Z-1563-2014 · View FDA record ↗ - Mar Cor PurificationTerminatedMar 14, 2014
Mar Cor Purification Millenium HX Portable Reverse Osmosis System. Model 3025975.
High inlet water pressure beyond specification and the solenoid valve does not meet application which could result in a delay in treatment.
Z-1213-2014 · View FDA record ↗ - Mar Cor PurificationTerminatedMar 13, 2014
Mar Cor Purification CWP Reverse Osmosis System. Models 101, 102, 104, and 106.
There exists a potential situation with the crimp connection at the pump head assembly. The potential exists that the reverse osmosis pump head wiring could build resistance resulting in resistive heating of the surrounding components. If this occurs, the pump head assembly may experience melting of the plastic components and potentially create smoke/fire and shut down of the unit.
Z-1201-2014 · View FDA record ↗ - AmeriWater IncTerminatedSep 6, 2012
AmeriWater MRO Dialysis RO+ System, AmeriWater 1303 Stanley Avenue, Dayton, OH 45404 (800) 535-5585 www.AMERIWATER.com.
The firm was notified that a malfunction of the device was caused by an incorrect fuse 32 volt 15 amp fuses instead of 250 volt 15 amp fuses, that was installed in the water system. The incorrect fuse may result in excessive heat in the fuse holder eventually resulting in failure of the device to operate.
Z-2321-2012 · View FDA record ↗
Registered firms
154 firms currently registered for this product code
Hach Company
AMES, IA, US
Isopure, Corp.
Louisville, KY, US
Baja Fur S.a. De C.v.
Tijuana BC. Baja California, MX
Baja Fur S.a. De C.v.
Tijuana Baja California, MX
Gambro Industries
MEYZIEU CEDEX Rhone, FR
Evoqua Water Technologies Llc
Minneapolis, MN, US
Ameriwater Llc.
DAYTON, OH, US
Fresenius Medical Care Renal Therapies Group, Llc
Waltham, MA, US
Sarmed Srl
IGLESIAS Sardegna, IT
Outset Medical, Inc.
San Jose, CA, US
Erika De Reynosa, S.a. De C.v.
CD, REYNOSA Tamaulipas, MX
Medica S.p.a.
Medolla Modena, IT
510(k) clearances
117 clearances for this product code
- Fresenius Medical Care Renal Therapies Group, LLCNov 14, 2025
K250471 · AquaC UNO H
- Fresenius Medical Care Renal Therapies Group, LLCOct 9, 2025
K251851 · DIASAFEplusUS (F00013010)
- Fresenius Medical Care North AmericaSep 9, 2025
K252181 · AquaA
- Specialty Water Technologies, Inc.Mar 17, 2025
K250514 · UPT Series Medical RO Water Treatment System
- Fresenius Medical Care Renal Therapies Group, LLCJun 13, 2024
K232953 · AquaBplus; AquaB LITE
- B.Braun Medical, Inc.Aug 16, 2023
K223479 · AQUAbase nX
- Evoqua Water Technologies, LLCJul 19, 2023
K231410 · RenaPure Endotoxin Retentive Filter
- AmeriWater, LLCFeb 13, 2023
K223656 · AmeriWater MediQA Reverse Osmosis System (MSP3HF)