Choledochoscope And Accessories, Flexible/rigid
Gastroenterology, Urology · 21 CFR 876.1500
to examine and perform procedures within the bile ducts. For reusable, flexible endoscopes in this product code, validated reprocessing instructions and reprocessing validation data must be included in a 510(k) submission (82 FR 26807, available at https://www.gpo.gov/fdsys/pkg/FR-2017-06-09/pdf/2017-12007.pdf).
Recent MDR events
2,300 adverse event reports on file
- OES CHOLEDOCHO FIBERSCOPEJul 30, 2026MalfunctionAizu Olympus Co., Ltd.9610595-2026-61466
- CHOLEDOCHO VIDEOSCOPEJul 27, 2026MalfunctionAizu Olympus Co., Ltd.9610595-2026-59191
- CHOLEDOCHO VIDEOSCOPEJul 22, 2026MalfunctionAizu Olympus Co., Ltd.9610595-2026-58829
- SPYSCOPE DS II ACCESS AND DELIVERY CATHETERJul 21, 2026MalfunctionBoston Scientific Corporation3005099803-2026-02908
- SPYSCOPE DS II ACCESS AND DELIVERY CATHETERJul 21, 2026MalfunctionBoston Scientific Corporation3005099803-2026-02907
- CHOLEDOCHO VIDEOSCOPEJul 20, 2026MalfunctionAizu Olympus Co., Ltd.9610595-2026-57891
- SPYGLASS DSJul 20, 2026MalfunctionBoston Scientific Corporation3005099803-2026-02905
- CHOLEDOCHO VIDEOSCOPEJul 20, 2026MalfunctionAizu Olympus Co., Ltd.9610595-2026-58278
- SPYSCOPE DS IIJul 16, 2026MalfunctionBoston Scientific Corporation3005099803-2026-02880
- CHOLEDOCHO VIDEOSCOPEJul 15, 2026MalfunctionAizu Olympus Co., Ltd.9610595-2026-56828
Event type breakdown
Recalls
9 recall events for this product code
- TANGENT ENDOSCOPY, LLCOpen, ClassifiedMay 15, 2026
Tangent Endoscopy, Tangent Single Use Digital Catheter. Model Numbers:
Affected devices exhibited fractures at the distal shaft tip without complete detachment.
Z-2209-2026 · View FDA record ↗ - Olympus Corporation of the AmericasOpen, ClassifiedJan 16, 2025
Olympus MAJ-891 Forceps/Irrigation Plug (Isolated Type). Model/Catalog Number: MAJ-891.
Potential for inadvertent retention of biomaterial when the reprocessing procedure is not performed as instructed, so as not completely removing and disassembling the device.
Z-0905-2025 · View FDA record ↗ - Aizu Olympus Co., Ltd.Open, ClassifiedNov 17, 2023
Ultrasonic gastrovideoscope-Real time ultrasound imaging,ultrasound guided needle aspiration and other endoscopic procedures within the upper gastrointestinal t
Channel air drying process was not validated, and that a small percentage of scopes returned to customers after repair had a wet channel. Water remaining in the channel of the endoscopes has the potential for contamination that could lead to the risk of infection
Z-0345-2024 · View FDA record ↗ - Pentax Medical CompanyTerminatedJun 28, 2016
Choledocho-Nephroscope
Pentax has become aware that operational/cleaning accessories and therapeutic devices (e.g., clips, stents, balloons, etc.) can become lodged in an endoscope's instrument channel.
Z-2066-2016 · View FDA record ↗ - Pentax Medical CompanyTerminatedJun 28, 2016
Choledochoscope
Pentax has become aware that operational/cleaning accessories and therapeutic devices (e.g., clips, stents, balloons, etc.) can become lodged in an endoscope's instrument channel.
Z-2067-2016 · View FDA record ↗ - Olympus Corporation of the AmericasTerminatedUnknown
Olympus CHF-CB30S Choledoscope
The CHF-CB30S Device did not have a 510(k) clearance. Additionally, the device has been associated with breakage of the insertion section and protrusion of metal parts, as well as breakage and displacement of the rubber on the bending section during surgical procedures.
Z-0119-2021 · View FDA record ↗ - Olympus Corporation of the AmericasTerminatedUnknown
Olympus DISPOSABLE GRASPING FORCEPS, FG-51D
Forceps do not comply with Olympus standards for the amount of force required to open and close the forceps
Z-1122-2022 · View FDA record ↗ - Boston Scientific CorporationTerminatedUnknown
SpyScope DS Access and Delivery diagnostic biliary catheter, M00546600
Certain lots of devices may have the working channel sleeve protruding from the camera cap which may result in injuries from minor tissue damage to significant bleeding.
Z-1133-2018 · View FDA record ↗ - Olympus Corporation of the AmericasTerminatedUnknown
URF-P6 Uretero-reno fiberscope and URF-P6R Uretero-reno fiberscope
Olympus is recalling the URF-P6/P6R endoscopes due to a similar device (URF-V2/V2R endoscopes) but not identical, where adverse event complaints associated with tissue trauma, perforation and insertion tubes which were stuck inside of patients that had to be surgically removed. In an effort to mitigate a potential risk to patient health, Olympus is undertaking this action to notify users of these complaints and the need for careful inspection of the endoscope prior to use in accordance with the instructions provided int heir notification letter.
Z-1251-2017 · View FDA record ↗
Registered firms
91 firms currently registered for this product code
Olympus Medical Systems Corp.
HACHIOJI-SHI Tokyo, JP
Karl Storz Se & Co. Kg
TUTTLINGEN Baden-Wurttemberg, DE
Enercon Technologies
GRAY, ME, US
Shanghai Seegen Photoelectric Technology Co., Ltd
Shanghai, CN
Gyrus Acmi, Inc.
Brooklyn Park, MN, US
Boston Scientific Corporation
Marlborough, MA, US
Synergy Health Ast, Srl
Alajuela, CR
Boston Scientific Limited
GALWAY, IE
Boston Scientific Limited
CLONMEL Tipperary, IE
Isomedix Operations, Inc.
Minneapolis, MN, US
Richard Wolf Medical Instruments Corp.
VERNON HILLS, IL, US
Karl Storz Endoscopy-america, Inc.
Auburn, MA, US
Hoya Corporation Pentax Lifecare Division
KURIHARA-SHI Miyagi, JP
Karl Storz Endovision, Inc.
CHARLTON, MA, US
Karl Storz Se & Co. Kg
NEUHAUSEN OBECK Baden-Wurttemberg, DE
Shenzhen Besdata Technology Co.,ltd
Shenzhen Guangdong, CN
Arvato Se
Hamburg, DE
Karl Storz Endoscopy-america, Inc.
El Segundo, CA, US
Karl Storz Se & Co Kg
TUTTLINGEN Baden-Wurttemberg, DE
510(k) clearances
43 clearances for this product code
- Mirco-Tech (Nanjing) Co., Ltd.Apr 3, 2026
K254153 · Single-use Video Scope; PB Digital Controller
- Mirco-Tech (Nanjing) Co., Ltd.Mar 19, 2026
K253139 · Disposable Distal Cap
- Scivita Medical Technology Co., Ltd.Jan 20, 2026
K251338 · Cholangioscope Visualization System (Single-use Video Cholangioscope: SCV-P-01G, SCV-P-02G; Full HD Visualization Endoscopic Image Processor: HDVS-S300A, HDVS-S300B, HDVS-S300C, HDVS-S300D)
- Tangent Endoscopy, LLCSep 12, 2025
K251170 · Tangent Single-Use Digital System: Tangent Single-Use Digital Catheter and Tangent Digital Controller
- Shanghai SeeGen Photoelectric Technology Co., Ltd.Mar 7, 2025
K243535 · Flexible Video-Choledochoscope (CHV-110J-U); Flexible Video-Choledochoscope (CHV-US120J-U)
- Shenzhen HugeMed Medical Technical Development Co., Ltd.Jan 21, 2025
K241444 · Biliary Pancreaticobiliary Scope System
- CenterPoint Systems, LLCMay 2, 2024
K233752 · Dragonfly Pancreaticobiliary Scope; Dragonfly Digital Controller; Dragonfly Instrument Channel Caps
- Shenzhen HugeMed Medical Technical Development Co., Ltd.Mar 6, 2024
K231497 · Choledochoscope System