Gauge, Pressure, Coronary, Cardiopulmonary Bypass
Cardiovascular · 21 CFR 870.4310
Recent MDR events
2 adverse event reports on file
Event type breakdown
Most-reported manufacturers
Recalls
5 recall events for this product code
- Medtronic Perfusion SystemsOpen, ClassifiedMay 10, 2024
Medtronic Disposable Pressure Display Sets:
Potential for unsealed sterile packing.
Z-1802-2024 · View FDA record ↗ - Medtronic Perfusion SystemsTerminatedJul 10, 2017
DLP Pressure Disposable Pressure Display Sets
Identification of small pinholes in a single packaging configuration of sterile pouches. A total of seven different products were affected.
Z-2768-2017 · View FDA record ↗ - Medtronic Perfusion SystemsTerminatedOct 20, 2011
Medtronic Pressure Display Box, Models 66000, 64000, 63000, 60000. It is capable of measuring pressure between -100 mmHg and +500 mmHg with an accuracy of +/-5
The DFU for the Medtronic Pressure Display Box, model 66000, states that, for display readings of -100 to +300 mmHg there will be an accuracy of +/-5 mmHg, and for display readings of +301 to +500 mmHg there will be an accuracy of +/-10 mmHg. Through reports from customers, Medtronic has become aware that the Pressure Display Box may not always accurately display readings. During use in the -40
Z-0077-2012 · View FDA record ↗ - Medtronic Perfusion SystemsTerminatedOct 20, 2011
Medtronic Disposable Pressure Display Set, Models 61000, 61006, 62000, 62006. Sterilized by Ethylene Oxide. Non-pyrogenic. Coiled PVC tubing with threaded tr
Pressure Display Set (models 61000, 61006, 62000, 62006) DFU will be updated to clarify that the intended use of the disposables is only for cardiopulmonary bypass surgery (procedures up to 6 hours). Use beyond 6 hours may result in air leakage in the system resulting in a pressure reading that is not representative of the actual line pressure.
Z-0078-2012 · View FDA record ↗ - Medtronic Perfusion SystemsTerminatedOct 20, 2011
Medtronic Intersept Custom Tubing Pack, which are designed as specified by the user. The following models contain a Pressure Display Set. Sterilized by Ethyl
Pressure Display Set (models 61000, 61006, 62000, 62006) DFU will be updated to clarify that the intended use of the disposables is only for cardiopulmonary bypass surgery (procedures up to 6 hours). Use beyond 6 hours may result in air leakage in the system resulting in a pressure reading that is not representative of the actual line pressure.
Z-0079-2012 · View FDA record ↗
Registered firms
6 firms currently registered for this product code
510(k) clearances
13 clearances for this product code
- Medtronic, Inc.Dec 2, 2011
K113235 · PRESSURE DISPLAY BOX,DLP DISPOSABLE PRESSURE DISPLAY SETS-NON STERILE VERSIONS
- Vascular Technology IncorporatedDec 27, 1994
K944764 · VTI DISPOSABLE PRESSURE DISPLAY SET
- Lifestream Int'L, Inc.Oct 31, 1991
K912045 · TMP PRESSURE ISOLATORR, TMP PRESSURE MONITOR SYST
- Shiley, Inc.May 10, 1990
K900797 · STOCKERT SHILEY DUAL PRESSURE CONTROL MODULE XR
- American Omni Medical, Inc.Nov 6, 1987
K873802 · PRESSURE BARRIER KIT CAT. NO. PBK-3
- Shiley, Inc.Sep 12, 1986
K862836 · STOCKERT-SHILEY CAPS AND CAPS DUAL PRESSURE MODULE
- Dlp, Inc.Aug 9, 1985
K852232 · PRESSURE DISPLAY BOX #60000/TUBING SET #61000
- Norton Texas Medical ProductsAug 27, 1984
K842194 · PRESSURE MONITOR