Catheter, Percutaneous, Neurovasculature
Cardiovascular · 21 CFR 870.1250
To provide vascular access to the neurovasculature for interventional or diagnostic procedures
Recent MDR events
1,669 adverse event reports on file
- PROWLER SELECTJul 31, 2026MalfunctionMedos International Sarl3008114965-2026-01007
- PROWLER SELECTJul 31, 2026MalfunctionMedos International Sarl3008114965-2026-00993
- Phenom CatheterJul 31, 2026MalfunctionMedtronic Mexico S. De R.l. De Cv9617601-2026-04863
- PROWLER SELECTJul 31, 2026MalfunctionMedos International Sarl3008114965-2026-00989
- PROWLER SELECTJul 31, 2026MalfunctionMedos International Sarl3008114965-2026-01001
- CEREBASEJul 31, 2026MalfunctionMedos International Sarl3008114965-2026-00999
- PROWLER SELECTJul 31, 2026MalfunctionMedos International Sarl3008114965-2026-01009
- RISTJul 30, 2026InjuryMicro Therapeutics, Inc. Dba Ev3 Neurova2029214-2026-01416
- Phenom CatheterJul 30, 2026Malfunction9617601-2026-04767
- PROWLER SELECTJul 30, 2026MalfunctionMedos International Sarl3008114965-2026-01030
Event type breakdown
Recalls
7 recall events for this product code
- Scientia Vascular, Inc.Open, ClassifiedFeb 26, 2025
Plato 17 Microcatheter REF PL17-160-090
Due to manufacturing non-conformance that resulted in channels in the seal on the packaging pouch. As a result, this could potential create a breach in the sterile barrier.
Z-1235-2025 · View FDA record ↗ - Stryker NeurovascularOpen, ClassifiedOct 7, 2024
The Trevo Trak 21 Microcatheter is a single-lumen, braided shaft, variable stiffness catheter with radiopaque marker(s) on the distal end and a luer hub on the
Stryker Neurovascular has observed that devices with Out of United States (OUS) approved Instructions for Use (IFU) and Packaging Labels (pouch and carton), different configurations, have been erroneously distributed to customers in the US.
Z-0021-2025 · View FDA record ↗ - Stryker NeurovascularOpen, ClassifiedMay 28, 2024
Trevo Trak 21 Microcatheter, Catalog: 90338
Neurovascular devices did not meet the minimum sample size required for endotoxin testing during manufacturing processes and are out of compliance with the AAMI ST72 standard, so these devices may exceed the acceptable limits of endotoxin levels; high levels of endotoxins may increase the risk of fever, shock and aseptic meningitis.
Z-1906-2024 · View FDA record ↗ - ROUTE 92 MEDICAL INCOpen, ClassifiedApr 24, 2024
Route 92 Medical Full Length 070 Access System, REF 7002, Rxonly, SterileEO. Used for Introduction of interventional devices into the neurovasculature.
Their is the potential for distal tip separation at the proximal marker band of the delivery catheters.
Z-1610-2024 · View FDA record ↗ - ROUTE 92 MEDICAL INCOpen, ClassifiedApr 24, 2024
Route 92 Medical, 070 Access System, REF 1004, Rxonly , Sterile EO. Used for introduction of interventional devices into the neurovasculature.
Their is the potential for distal tip separation at the proximal marker band of the delivery catheters
Z-1612-2024 · View FDA record ↗ - Medos International SarlOpen, ClassifiedMar 13, 2024
CERENOVUS CEREBASE DA Guide Sheath, Part Numbers:
Medos has received an increase in complaints for CEREBASE DA Guide Sheath with reports of fractures at the distal end, which may result in surgical procedural delay, vascular injury and in extreme rare occasions it may result in embolism.
Z-1284-2024 · View FDA record ↗ - Stryker, Inc.Open, ClassifiedFeb 14, 2024
Stryker Neurovascular, Trevo Trak 21 Microcatheter, REF 90338, 0.021in X162cm
The microcatheter IFU contains an intended use that has not been evaluated by the FDA.
Z-1085-2024 · View FDA record ↗
Registered firms
242 firms currently registered for this product code
Creganna Medical S. R. L
San Rafael Heredia, CR
Shanghai Heartcare Medical Technology Corporation Limited
Shanghai, CN
Stryker Neurovascular
Salt Lake City, UT, US
Wallaby Medical
Laguna Hills, CA, US
Sterigenics Us Llc
Los Angeles, CA, US
Cpe1, Llc Dba Greatbatch Medical
Southwest Ranches, FL, US
Stryker Neurovascular
Fremont, CA, US
Sterigenics U.s., Llc
Salt Lake City, UT, US
Asahi Intecc (thailand) Co., Ltd.
Amphur Muang Pathumthani Pathum Thani, TH
Alembic Llc
Mountain View, CA, US
Medtronic Distribution Center
Memphis, TN, US
Bend It Technologies Ltd.
Petach Tikva Central, IL
Shanghai Wallaby Medical Technologies Co., Inc.
Shanghai, CN
Covidien Medical Products (shanghai) Manufacturing Llc
Shanghai, CN
Andersen Scientific, Inc.
Morrisville, NC, US
Isomedix Operations Inc.
Northborough, MA, US
Sterigenics Shanghai Eto Ltd.
Shanghai, CN
Micro Therapeutics, Inc. Dba Ev3 Neurovascular
Irvine, CA, US
Perfuze
Dangan Galway, IE
Isomedix Operations, Inc.
Temecula, CA, US
Balt Usa, Llc
Irvine, CA, US
Imperative Care Inc.
Campbell, CA, US
510(k) clearances
96 clearances for this product code
- Balt USA, LLCJul 13, 2026
K260199 · SLIM Microcatheter
- Perfuze, Ltd.Jul 9, 2026
K253901 · Millipede88 Access Catheter
- Stryker NeurovascularJul 1, 2026
K261889 · Trevo Trak 21 Microcatheter
- Microvention Inc. d/b/a Terumo NeuroJun 30, 2026
K261808 · ISAAC Neurovascular Navigation Catheter
- MicroVention, Inc., d/b/a Terumo NeuroJun 9, 2026
K261549 · BOBBY Balloon Guide Catheter
- Suzhou Zenith Vascular SciTech LimitedMay 22, 2026
K253359 · Zenith Distal Access Long Sheath
- Asahi Intecc Co., Ltd.May 11, 2026
K254178 · SAYA 86 Radial Access Guide Catheter
- Sonorous NV, Inc.Apr 21, 2026
K254046 · BosCATH Support Catheter