Laparoscopic Accessories, Gynecologic
Obstetrics/Gynecology · 21 CFR 884.1720
Exempt laparoscope accessories are non-powered, non-inflatable, simple manual mechanical devices, e.g., cannula, graspers, forceps, dissectors, scissors, etc. A gynecologic laparoscope is a device used to permit direct viewing of the organs within the peritoneum by a telescopic system introduced through the abdominal wall. It is used to perform diagnostic and surgical procedures on the female genital organs. This generic type of device may include: Trocar and cannula, instruments used through an operating channel, scope preheater, light source and cables, and component parts.
Recent MDR events
508 adverse event reports on file
- DIRECT DRIVE REPOSABLE GRASPERSJul 16, 2026MalfunctionApplied Medical Resources2027111-2026-00653
- EPIX LAPAROSCOPIC GRASPERJun 19, 2026MalfunctionApplied Medical Resources2027111-2026-00611
- AESCULAP PRESTIGE LINE ATRAUMATIC LAPAROSCOPIC GRASPING FORCEPSJun 17, 2026MalfunctionAesculap, IncMW5189621
- EPIX LAPAROSCOPIC GRASPERMay 1, 2026MalfunctionApplied Medical Resources2027111-2026-00538
- EPIX LAPAROSCOPIC GRASPERMar 10, 2026MalfunctionApplied Medical Resources2027111-2026-00430
- EPIX LAPAROSCOPIC GRASPERMar 10, 2026MalfunctionApplied Medical Resources2027111-2026-00433
- EPIX LAPAROSCOPIC GRASPERFeb 23, 2026MalfunctionApplied Medical Resources2027111-2026-00394
- PRESTIGE GRASPER FORCEPSFeb 12, 2026InjuryAesculap Inc.2916714-2026-00006
- INSUFFLATION NEEDLEJan 29, 2026MalfunctionApplied Medical Resources Corp.MW5183017
- DIRECT DRIVE REPOSABLE GRASPERSJan 13, 2026MalfunctionApplied Medical Resources2027111-2026-00325
Event type breakdown
Recalls
7 recall events for this product code
- JosNoe Medical, Inc.TerminatedJan 30, 2016
PS-500 Scope Warmer; 10 units per box.
Damage to package seals potentially compromising sterility.
Z-0732-2016 · View FDA record ↗ - Applied Medical Resources CorpTerminatedJun 7, 2013
Applied Medicals Epix and Direct Drive Laparoscopic Graspers, Model Numbers C4130 and C4140.
Applied Medical is conducting a voluntary recall on specific lot numbers of its Epix and Direct Drive Laparoscopic Graspers. When the ratchet trigger is activated, if a great enough force is applied, there is a potential for the trigger to fracture and the jaws to remain in the closed position. The likelihood of this situation to occur and result in permanent patient injury is highly unlikely;
Z-1521-2013 · View FDA record ↗ - Applied Medical Resources CorpTerminatedUnknown
Epix latis GRASPER, 5 mm x 35 cm, REF C4130, Qty: 10, Sterile R, CE, Rx ONLY, UDI: (01)00607915110147
There may be a slightly protruding rivet on the distal end of the laparoscopic grasper which has the potential for tissue to catch on it during use and lead to tissue damage.
Z-2158-2020 · View FDA record ↗ - Applied Medical Resources CorpTerminatedUnknown
Epix latis GRASPER, 5mm x 45 cm, REF: C4140, Qty: 10, Sterile R, CE, Rx ONLY, UDI: (01)00607915110154
There may be a slightly protruding rivet on the distal end of the laparoscopic grasper which has the potential for tissue to catch on it during use and lead to tissue damage.
Z-2159-2020 · View FDA record ↗ - Applied Medical Resources CorpTerminatedUnknown
DR. THAMES - LAP CHOLE, REF: K0880, UDI: (01)30607915139620
There may be a slightly protruding rivet on the distal end of the laparoscopic grasper which has the potential for tissue to catch on it during use and lead to tissue damage.
Z-2160-2020 · View FDA record ↗ - Applied Medical Resources CorpTerminatedUnknown
Clip Applier Kit, REF: K2887, UDI: (01)30607915139132(17)220822(30)1(10)
There may be a slightly protruding rivet on the distal end of the laparoscopic grasper which has the potential for tissue to catch on it during use and lead to tissue damage.
Z-2161-2020 · View FDA record ↗ - Cook Inc.TerminatedUnknown
Clarke-Reich Laparoscopic Knot Pusher
reprocessing instructions do not provide sufficient detailed information for the cleaning, disinfection, and sterilization of these products
Z-2537-2017 · View FDA record ↗
Registered firms
81 firms currently registered for this product code
Microline Surgical, Inc
BEVERLY, MA, US
Jackson Medical Group
Marietta, GA, US
Applied Medical Distribution Center
Irvine, CA, US
Isomedix Operations, Inc.
Temecula, CA, US
Tonglu Qianyan Medtech Co.,ltd
hangzhou Zhejiang, CN
Josnoe Medical Inc
Nixa, MO, US
Peters Surgical
DOMALAIN Bretagne, FR
Applied Medical Resources Corp.
RSM, CA, US
Bioteque Corporation Yilan Science Park Factory
Yilan City, TW
Trokamed Gmbh
GEISINGEN Baden-Wurttemberg, DE
Heinrich Medizintechnik Gmbh
Stuttgart Baden-Wurttemberg, DE
Steriservices
Bernay Eure, FR
Hebumedical Gmbh
TUTTLINGEN Baden-Wurttemberg, DE
National Advanced Endoscopy Devices, Inc.
CANOGA PARK, CA, US
Gyrus Acmi, Inc.
Brooklyn Park, MN, US
Endomed, Llc
Orlando, FL, US
Surgipros Llc
Palmetto, FL, US
Tech Medical Services, Inc.
Nixa, MO, US
Bema-gmbh & Co. Kg
EMMINGEN Baden-Wurttemberg, DE
Cook Incorporated
Bloomington, IN, US
Laparomed Private Limited
Mumbai Maharashtra, IN
Integra Lifesciences Production Corporation
Mansfield, MA, US
Deroyal Industries, Inc.
NEW TAZEWELL, TN, US
Hunan Handlike Minimally Invasive Surgery Co., Ltd.
Changsha Hunan, CN
Artisan Medical
Medford, NJ, US
510(k) clearances
0 clearances for this product code
No 510(k) clearances on file for this product code.