Reagents, Specific, Analyte
Pathology · 21 CFR 864.4020
Recent MDR events
74 adverse event reports on file
- VENTANA EBER PROBEFeb 11, 2026MalfunctionVentana Medical Systems Inc.2028492-2026-00465
- BD CD38 PE-CY7Dec 4, 2025MalfunctionBd Caribe, Ltd3008352382-2025-00003
- VYSIS LSI BCR/ABL, DUAL COLOR, DUAL FUSION TRANSLOCATION PROBE SETMar 27, 2025MalfunctionAbbott Molecular, Inc.3005248192-2025-00077
- POLYCLONAL RABBIT ANTI-HUMAN C-ERBB-2 ONCOPROTEINSep 20, 2024InjuryAgilent Technologies Singapore (intl.) Pte Ltd.3003423869-2024-00056
- CD10 (HI10A) APCApr 4, 2024MalfunctionBecton Dickinson Caribe Ltd.2647876-2024-00062
- CD19 PE-CY7 CEJan 24, 2024MalfunctionBecton Dickinson Caribe Ltd.2647876-2024-00014
- BD® CD16 (3G8) PERCP-CY¿5.5Sep 19, 2023MalfunctionBecton, Dickinson And Company, Bd Biosciences2647876-2023-00165
- CD5 PE-CY7 CEMar 10, 2023MalfunctionBecton Dickinson Caribe Ltd.2647876-2023-00007
- CD5 PE-CY7 CEMar 10, 2023MalfunctionBecton Dickinson Caribe Ltd.2647876-2023-00006
- BD CD15 FITCNov 8, 2022MalfunctionBecton, Dickinson And Company, Bd Biosciences2916837-2022-00336
Event type breakdown
Recalls
43 recall events for this product code
- GET TESTED INTERNATIONAL ABOpen, ClassifiedDec 1, 2025
Herpes (HSV-1 & HSV-2) Test
Distribution without premarket approval/clearance.
Z-0740-2026 · View FDA record ↗ - Kreatech Biotechnology BvOpen, ClassifiedNov 22, 2024
Kreatech PapV-16, Flu labeled ISH probe, to detect presence of HPV-16 DNA inserts in
The DNA fragments for this specific lot number are too large, resulting in potential background around the cells due to suboptimal hybridization. An absence of signal could also be observed as a result of the suboptimal hybridization of the larger DNA fragments. The user may interpret potential background as a false positive result and an absence of signal as a false negative result, if proper positive and negative controls are not included.
Z-0522-2025 · View FDA record ↗ - Abbott Molecular, Inc.Open, ClassifiedFeb 26, 2024
In-vitro diagnostic kits:
Products that were intended for export only which were not approved or registered in accordance with U.S. specifications were shipped to U.S. customers.
Z-1189-2024 · View FDA record ↗ - Becton, Dickinson and Company, BD BiosciencesOpen, ClassifiedJan 5, 2024
CD11b APC: ASR, REF: 340936, and CE, REF: 333143
In vitro diagnostics product that impacts the quality of cell staining can cause low or dim fluorescence signal, which can lead to potential false negative results and misdiagnosis of hematological malignancy, delayed treatment, and the need for additional patient samples.
Z-0641-2024 · View FDA record ↗ - Cytocell Ltd.Open, ClassifiedJul 20, 2023
RET Proximal Probe. Used in Fluorescence in situ hybridization (FISH), a laboratory technique for detecting and locating a specific DNA sequence on a chromosome
DNAs used during the manufacture of two affected models were accidentally inverted during manufacturing.
Z-2209-2023 · View FDA record ↗ - Cytocell Ltd.Open, ClassifiedJul 20, 2023
RET Distal Probe. Used in Fluorescence in situ hybridization (FISH), a laboratory technique for detecting and locating a specific DNA sequence on a chromosome.
DNAs used during the manufacture of two affected models were accidentally inverted during manufacturing.
Z-2210-2023 · View FDA record ↗ - Cytocell Ltd.TerminatedDec 1, 2022
CytoCell BCL11B Proximal in FITC Spectrum-LDT for investigation T-cell related malignancy.
Device is mislabeled. The package insert for this ASR device contains a chromomap - an image showing the position the FISH probe maps to on the specific chromosome. For this device the chromomap in version 1 of the package insert is incorrect and doesn't not match the probe design or specification contained on the package insert
Z-0353-2023 · View FDA record ↗ - Cytocell Ltd.TerminatedNov 30, 2022
CytoCell BCL11B Distal in Texas Red Spectrum- Analyte Specific Reagent
An error with the chromomap on version 1 of the package insert which is incorrect. The nucleotide locations specified in the insert are correct but the map has been created using the wrong coordinates.
Z-0341-2023 · View FDA record ↗ - Becton, Dickinson and Company, BD BiosciencesTerminatedMay 13, 2020
Analyte specific reagent. REF/UDI: 641408/641408-4012-1-1 (US); 641417/641417-1157-1-01 (OUS); 641399/641399-4012-1-01 (US Research Use Only) - Product Usage: C
False positive reaction on the reagent.
Z-1971-2020 · View FDA record ↗ - Cytocell Ltd.TerminatedJun 19, 2019
Aquarius D13S319 Plus Deletion Probe, Model LPH068-A
There is an error in the chromomap on the package insert.
Z-1843-2019 · View FDA record ↗
Registered firms
117 firms currently registered for this product code
Alere San Diego, Inc.
Pomona, CA, US
Diagnostic Biosystems
Pleasanton, CA, US
Healthbio, Inc
Hayward, CA, US
Iq Products B.v.
GRONINGEN, NL
Metasystems Probes Gmbh
Altlussheim Baden-Wurttemberg, DE
Qiagen
Germantown, MD, US
Empire Genomics Corp.
Depew, NY, US
Bio Sb, Inc.
Santa Barbara, CA, US
Immco Diagnostics, Inc.
Williamsville, NY, US
Cytocell Limited
CAMBRIDGE Cambridgeshire, GB
Exbio Praha, A.s.
Vestec Praha-Zapad, CZ
Diaglogic Biolabs (xiamen) Co., Ltd.
Xiamen Fujian, CN
Menarini Silicon Biosystems Inc.
Huntingdon Valley, PA, US
Miltenyi Biotec B. V. & Co. Kg Branch Teterow
Teterow Mecklenburg-Western Pomerania, DE
Miltenyi Biotec B. V. & Co. Kg
Bergisch Gladbach North Rhine-Westphalia, DE
Celnovte Biotechnology Co., Ltd
zhengzhou Henan, CN
Diasorin Italia S.p.a Uk Branch
Dartford Kent, GB
Zeta Corporation
Monrovia, CA, US
Diasorin Molecular Llc
CYPRESS, CA, US
Immunotech Sas, A Beckman Coulter Company
MARSEILLE, CEDEX 9 Bouches-du-Rhone, FR
Altona Diagnostics Gmbh
Hamburg, DE
Becton, Dickinson And Company, Bd Biosciences
San Diego, CA, US
Baebies Inc.
Durham, NC, US
Wallac Oy
TURKU Varsinais-Suomi, FI
Caprico Biotechnologies, Inc.
Duluth, GA, US
510(k) clearances
0 clearances for this product code
No 510(k) clearances on file for this product code.