Disinfector, Medical Devices
General Hospital · 21 CFR 880.6992
Recent MDR events
1,315 adverse event reports on file
- AMSCO 7053HP Washer-DisinfectorJul 30, 2026InjuryCorporation Steris Canada9680353-2026-00032
- 86-SeriesJul 29, 2026InjuryGetinge Disinfection Ab3013876692-2026-00094
- AMSCOJul 29, 2026InjuryCorporation Steris Canada9680353-2026-00031
- 86-SeriesJul 28, 2026InjuryGetinge Disinfection Ab3013876692-2026-00093
- 86-SeriesJul 27, 2026InjuryGetinge Disinfection Ab9616031-2026-0000011
- 86-SeriesJul 27, 2026InjuryGetinge Disinfection Ab9616031-2026-0000012
- RELIANCE VISIONJul 16, 2026MalfunctionCorporation Steris Canada9680353-2026-00030
- AMSCOJul 9, 2026MalfunctionCorporation Steris Canada9680353-2026-00029
- AMSCOJul 2, 2026MalfunctionCorporation Steris Canada9680353-2026-00028
- AMSCOJun 9, 2026MalfunctionCorporation Steris Canada9680353-2026-00027
Event type breakdown
Recalls
31 recall events for this product code
- Steris CorporationOpen, ClassifiedDec 11, 2025
AMSCO 7052HP Washer/Disinfector
Wire connected to the electrical box may shift out of its intended position, which may result in electrical arcing. Electrical arcing remains internal within the unit (no risk of shock to users).
Z-0909-2026 · View FDA record ↗ - Steris CorporationOpen, ClassifiedDec 11, 2025
AMSCO 7053HP Washer/Disinfector
Wire connected to the electrical box may shift out of its intended position, which may result in electrical arcing. Electrical arcing remains internal within the unit (no risk of shock to users).
Z-0910-2026 · View FDA record ↗ - Getinge Disinfection AbOpen, ClassifiedOct 1, 2025
Getinge 88-Series Washer- Disinfector. Model Number: 88-5.
Potential for device to overheat during operation if the circulation pressure calibration was not performed or had been performed incorrectly, and the low-pressure alarm is not triggered.
Z-0016-2026 · View FDA record ↗ - Getinge Disinfection AbOpen, ClassifiedMay 5, 2025
Washer Disinfector Aquadis 56; Model Number: 56A
The frequency inverter is not programmed by supplier according to specification which causes the circulation pump to start earlier than expected, resulting in additional wear and tear, earlier than expected, on the axial seal in the pump housing.
Z-1720-2025 · View FDA record ↗ - Getinge Disinfection AbOpen, ClassifiedMay 5, 2025
Washer Disinfector Aquadis 56; Model Number: 56M
The frequency inverter is not programmed by supplier according to specification which causes the circulation pump to start earlier than expected, resulting in additional wear and tear, earlier than expected, on the axial seal in the pump housing.
Z-1721-2025 · View FDA record ↗ - Steris CorporationOpen, ClassifiedMay 17, 2023
Reliance Vision Multi-Chamber Washer/Disinfector, Reference Number FH83062
In the remote occurrence in which the electrical contactor component present in the drying chambers of the Reliance Vision Multi-Chamber Washer/Disinfector malfunctions, the heating elements in the drying chamber could overheat, eventually resulting in smoke and/or fire.
Z-1595-2023 · View FDA record ↗ - Maquet Cardiovascular Us Sales, LlcTerminatedFeb 18, 2020
Getinge 88-Series-washer disinfectors intended for cleaning, disinfection and drying
Potential leakage that may occur due to ruptured spot welds in the chamber, could generate a situation for the user such as risk for slipping or infection from contaminated water
Z-1475-2020 · View FDA record ↗ - Natus Medical IncorporatedTerminatedJun 2, 2017
The Olympic Pasteurmatic 3000 and Olympic Pasteurmatic 3500 are intended for cleaning and high-level disinfection of respiratory therapy and anesthesia equipmen
Olympic Pasteurmatic 3000/3500 Systems are recalled because they do not fully meet todays regulatory requirements. Given the age of the products design, component and technology obsolescence, and the time involved in fully complying with the latest design and development standards, the firm decided to recall of the Olympic Pasteurmatic 3000/3500 System devices by means of disabling the devices.
Z-2701-2017 · View FDA record ↗ - Getinge Disinfection AbTerminatedAug 25, 2015
Getinge 86 Series Washer/Disinfector with G1 control system software, Model 8666 and Model 8668. For use in healthcare facilities and laboratories where reusabl
Getinge Disinfection AB has initiated a Field Correction due to the potential for unauthenticated remote access to the product over the network.
Z-2419-2015 · View FDA record ↗ - Getinge Disinfection AbTerminatedDec 23, 2014
GETINGE 46-SERIES Medical Washer-Disinfector, Models 46-4 and 46-5, with PACS 300/350 Control Series with dryer --- Class II, exempt from 510(k) requirements.
Getinge Disinfection AB received complaints regarding sediment residuals in the manifold of the washer and disinfector of Getinge 46-Series (CM302) with PACS 300/350 control. After performing detailed root cause analysis, the firm has identified the problem as insufficient water flow throughout the manifold due to formation of air pockets where sedimentation may occur.
Z-0852-2015 · View FDA record ↗
Registered firms
40 firms currently registered for this product code
Steris Canada Ulc
QUEBEC, CA
Dent4you Ag
Heerbrugg Sankt Gallen, CH
Xiamen Forsound Hearing Technology Co.,ltd.
Xiamen Fujian, CN
Ear Technology Corporation
Johnson City, TN, US
Mark Enterprises
Nashik Maharashtra, IN
Bluewave Technologies, Inc.
Orange City, FL, US
Uv Smart Technologies B.v.
Rijswijk Zuid-Holland, NL
Medease Life Co.,ltd
DANYANG Jiangsu, CN
Bellus Medical, Llc
Johnson City, TN, US
Guangdong Eraclean Technology Co.,ltd
Zhongshan City Guangdong, CN
Heuer International (a Division Of Gst Corporation Limited)
NOIDA Uttar Pradesh, IN
Endonest Medical Systems Llp
PALGHAR Maharashtra, IN
Scican Ltd.
TORONTO Ontario, CA
Getinge Ab
POZNAN Wielkopolskie, PL
Steelco S.p.a.
Riese Pio X Treviso, IT
Albert Browne Ltd.
LEICESTER, GB
Skytron, Llc
Grand Rapids, MI, US
Aopu Lighting (jinyun) Co., Ltd.
Lishui Zhejiang, CN
Eledricity
Merelbeke-Melle Oost-Vlaanderen, BE
Getinge Disinfection Ab
VAXJO Kronoberg, SE
Sunset Healthcare Solutions Warehouse
Phoenix, AZ, US
Dongguan Yingfeng Metal & Plastic Products Co., Ltd
Dongguan Guangdong, CN
Sunset Healthcare Solutions, Inc.
CHICAGO, IL, US
Sunset Healthcare Solutions Central Warehouse
Elgin, IL, US
Belimed Ag
Zug, CH
510(k) clearances
2 clearances for this product code