Prostate-specific Antigen (psa) For Management Of Prostate Cancers
Immunology · 21 CFR 866.6010
Recent MDR events
653 adverse event reports on file
- ATELLICA IM PROSTATE-SPECIFIC ANTIGEN (PSA)Jul 14, 2026MalfunctionSiemens Healthcare Diagnostics, Inc.1219913-2026-00145
- VITROS IMMUNODIAGNOSTIC PRODUCTS PSA REAGENT PACKJun 17, 2026MalfunctionOrtho-clinical Diagnostics, Inc.3007111389-2026-00113
- VITROS IMMUNODIAGNOSTIC PRODUCTS PSA REAGENT PACKJun 17, 2026MalfunctionOrtho-clinical Diagnostics, Inc.3007111389-2026-00114
- VITROS IMMUNODIAGNOSTIC PRODUCTS PSA REAGENT PACKFeb 20, 2026MalfunctionOrtho-clinical Diagnostics, Inc.3007111389-2026-00036
- VITROS IMMUNODIAGNOSTIC PRODUCTS PSA REAGENT PACKFeb 20, 2026MalfunctionOrtho-clinical Diagnostics, Inc.3007111389-2026-00037
- VITROS IMMUNODIAGNOSTIC PRODUCTS PSA REAGENT PACKFeb 20, 2026MalfunctionOrtho-clinical Diagnostics, Inc.3007111389-2026-00038
- ATELLICA IM PROSTATE-SPECIFIC ANTIGEN (PSA)Dec 8, 2025MalfunctionSiemens Healthcare Diagnostics Inc.1219913-2025-00217
- VITROS IMMUNODIAGNOSTIC PRODUCTS PSA REAGENT PACKOct 1, 2025MalfunctionOrtho-clinical Diagnostics, Inc.3007111389-2025-00107
- ATELLICA IM PROSTATE-SPECIFIC ANTIGEN (PSA)Jul 17, 2025MalfunctionSiemens Healthcare Diagnostics, Inc.1219913-2025-00144
- ACCESS PSAFeb 13, 2025InjuryBeckman Coulter, Inc2122870-2025-00058
Event type breakdown
Recalls
12 recall events for this product code
- GET TESTED INTERNATIONAL ABOpen, ClassifiedDec 1, 2025
PSA Test
Distribution without premarket approval/clearance.
Z-0795-2026 · View FDA record ↗ - Qualigen IncTerminatedDec 19, 2013
FastPack Total PSA Immunoassay
Qualigen initiated this recall because the FastPack kit may cause lower than expected results due to a manufacturing defect.
Z-0547-2014 · View FDA record ↗ - BioCheck IncTerminatedMar 11, 2011
PSA ELISA Kit.
Product labels indicate that the products are for IVD use and they do not have an approved 510(k).
Z-1631-2011 · View FDA record ↗ - BioCheck IncTerminatedMar 11, 2011
Free PSA ELISA Kit.
Product labels indicate that the products are for IVD use and they do not have an approved 510(k).
Z-1632-2011 · View FDA record ↗ - Beckman Coulter IncTerminatedApr 28, 2009
Beckman Coulter Access Immunoassay System Hybritech PSA Calibrators, Product Number: 37205.
Beckman Coulter incorrectly shipped Access Hybritech PSA calibrators containing dual calibration cards (Hybritech and WHO) to some Access Hybritech PSA Customers. The WHO calibration for PSA is not currently approved in the United States.
Z-1197-2009 · View FDA record ↗ - Qualigen IncTerminatedDec 22, 2008
FastPack(R) Total PSA Immunoassay; Catalog #: 25000001
The recall was initiated after the firm investigation of customer complaints of falsely elevated results determined the product was not meeting product performance expectations.
Z-0500-2009 · View FDA record ↗ - Siemens Medical Solutions DiagnosticsTerminatedSep 16, 2008
COAT-A-COUNT PSA IRMA kit (IKPS1, 2, 5, X). The device is intended as an aid in monitoring patients for disease progress or response to therapy.
The field action was initiated after the firm confirmed that the Coat-A-Count PSA IRMA kit (IKPS1, 2, 5, X) exhibits a low bias, which is evident when comparing results with other methods, including the IMMULITE PSA kits. Coat-A-Count PSA IRMA results are, for example, approximately 20% lower when compared to results obtained with the IMMULITE 2000 Third Generation PSA assay (L2KUP).
Z-2090-2008 · View FDA record ↗ - Roche Diagnostics Corp.TerminatedJan 11, 2006
Roche Elecsys total PSA, catalog number 11731262322.
There is the possibility of high results with sera expected to have non-detectable levels of tPSA if these reagent lots are used in combination on the Modular Analytics E170 analyzer.
Z-0381-06 · View FDA record ↗ - Roche Diagnostics Corp.TerminatedJan 11, 2006
Roche Elecsys total PSA CalSet, catalog number 11731696322.
There is the possibility of high results with sera expected to have non-detectable levels of tPSA if these reagent lots are used in combination on the Modular Analytics E170 analyzer.
Z-0382-06 · View FDA record ↗ - Dade Behring IncTerminatedMay 29, 2003
Dimension TSPA (Total Prostate Specific Antigen) Flex Reagent Cartridge. The product is shipped 4 cartridges per carton.
test results may be inaccurate by 0.2 to 0.5 ng/mL
Z-0873-03 · View FDA record ↗
Registered firms
41 firms currently registered for this product code
Qualigen, Inc.
CARLSBAD, CA, US
Roche Diagnostics Gmbh
MANNHEIM Baden-Wurttemberg, DE
Monobind, Inc.
Lake Forest, CA, US
Tosoh Bioscience, Inc.
Grove City, OH, US
Diamond Diagnostics Inc.
Budapest, HU
Ortho-clinical Diagnostics, Inc.
Rochester, NY, US
Tosoh Corp.
Chuo-ku Tokyo, JP
Epitope Diagnostics, Inc.
SAN DIEGO, CA, US
Beckman Coulter, Inc.
CHASKA, MN, US
Siemens Healthcare Diagnostics Products Limited
LLANBERIS Wales, GB
Siemens Healthcare Diagnostics Inc.
Tarrytown, NY, US
Ortho-clinical Diagnostics
Pencoed Bridgend, GB
Abbott Ireland
SLIGO, IE
Siemens Healthcare Diagnostics Inc.
E Walpole, MA, US
Ortho-clinical Diagnostics, Inc.
RARITAN, NJ, US
Abbott Laboratories
Lake Forest, IL, US
Alius Scientific,llc
Carolina, PR, US
Nanoentek Inc
Seoul, KR
Tosoh Aia, Inc.
TOYAMA, JP
Fujirebio Diagnostics, Inc.
Malvern, PA, US
Drg International, Inc.
Springfield, NJ, US
Nanoentek Inc
Hwaseong Gyeonggi, KR
510(k) clearances
34 clearances for this product code
- Siemens Healthcare Diagnostics, Inc.Jan 5, 2026
K251630 · Atellica IM Total PSA II (tPSAII)
- Nanoentek USA, Inc.May 17, 2017
K162378 · FREND PSA PLUS (reagent cartridge)
- Nanoentek, Inc.May 29, 2013
K124056 · FREND PSA PLUS (REAGENT CARTRIDGE)
- Dade Behring, Inc.May 15, 2003
K031343 · TPSA FLEX REAGENT CARTRIDGE
- Bayer Diagnostics Corp.Dec 17, 2002
K022177 · PROSTATE SPECIFIC ANTIGEN (PSA) ASSAY FOR THE ADVIA INTEGRATED MODULAR SYSTEM
- Bayer Corp.Dec 17, 2002
K022288 · COMPLEXED PROSTATE SPECIFIC ANTIGEN (CPSA) ASSAY FOR THE BAYER ADVIA INTEGRATED MODULE SYSTEM
- bioMerieux, Inc.Apr 24, 2001
K010550 · VIDAS TOTAL PROSTATE SPECIFIC ANTIGEN (TPSA), MODEL 30 428
- Dade Behring, Inc.Feb 28, 2001
K003963 · DIMENSION PSA FLEX REAGENT CARTRIDGE