Recalls for Bit, Drill
114 on file
- Waldemar Link GmbH & Co. KG (Mfg Site)Open, ClassifiedMar 27, 2026
The surgical technique for the Embrace Shoulder Instruments - Drill Tower has mixed-up article numbers in the overview of the instruments. However, the individual surgical steps described in the surgical technique are correct.
- Waldemar Link GmbH & Co. KG (Mfg Site)Open, ClassifiedMar 27, 2026
The surgical technique for the Embrace Shoulder Instruments - Drill Tower has mixed-up article numbers in the overview of the instruments. However, the individual surgical steps described in the surgical technique are correct.
- Waldemar Link GmbH & Co. KG (Mfg Site)Open, ClassifiedMar 6, 2024
The surgical techniques for the Embrace Shoulder Instruments -Drill Tower (Article REF 645-081/62 & /63) have mixed-up type descriptions ("standard" vs "wedged") in the overview of the instruments.
- Waldemar Link GmbH & Co. KG (Mfg Site)Open, ClassifiedMar 6, 2024
The surgical techniques for the Embrace Shoulder Instruments -Drill Tower (Article REF 645-081/62 & /63) have mixed-up type descriptions ("standard" vs "wedged") in the overview of the instruments.
- Biomet, Inc.TerminatedDec 17, 2020
Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device.
- Biomet, Inc.TerminatedMay 26, 2016
Insufficient seal strength on sterile barrier packaging. The seal could be jeopardized causing the sterile barrier to be compromised and the product could become nonsterile. If the product becomes non-sterile and is used or implanted, it may lead to an infection.
- Synthes (USA) Products LLCTerminatedMay 23, 2016
The sterile packaging may be compromised. A protective cap is to be secured on the tip of the drill bit. If the protective cap is not secured, the drill bit may puncture the sterile barrier.
- Synthes (USA) Products LLCTerminatedMay 23, 2016
The sterile packaging may be compromised. A protective cap is to be secured on the tip of the drill bit. If the protective cap is not secured, the drill bit may puncture the sterile barrier.
- Trilliant Surgical Ltd.TerminatedAug 24, 2015
The cannulation of the 3.0/4.0 Cannulated Drill Bit inner diamter is too small to allow for the guide wire to pass completely through.
- Synthes, Inc.TerminatedJun 4, 2015
affected parts and lots of the Cannulated Drill Bits have the potential to break during use
- The Anspach Effort, Inc.TerminatedJan 11, 2014
Recall was initiated due to the observation of separation between clear layers of the pouch during real time aging studies. As a result, it is possible to have a breach in the sterile barrier.
- Synthes USA HQ, Inc.TerminatedNov 27, 2013
There is a possibility for the Guide Wires of the Slipped Capital Femoral Epiphysis System to stick in the cannulation of the drill bit and the drill bits to break during surgery.
- Surgical Instrument Service And Savings, Inc.TerminatedJul 1, 2013
The seal which maintains a sterile barrier for reprocessed medical devices became compromised to the point where product may fall out of the pouch.
- Zimmer, Inc.TerminatedMay 24, 2013
Zimmer is initiating a lot specific recall of the Trabecular Metal" Tibia Stop Drill due to the potential of the outside diameter being oversized. As a result, there is a potential for the drill to not pass through the applicable drill guide.
- Stryker Howmedica Osteonics Corp.TerminatedMay 1, 2013
Stryker Orthopaedics has received a report indicating that the scale of the AxSOS Calibrated Drill Bit 4.3,,X263mm, flat , manufactured by Stryker Osteosynthesis, is incorrect. The incorrect scale could result in the surgeon selecting a screw that is 10mm longer than intended.
- Orthohelix Surgical Designs IncTerminatedMar 22, 2013
The firm was notified by a customer that there was a burr on the inside end of the drill bit resulting in the drill bit not fitting over the associated guide wire.
- Linvatec Corp. dba ConMed LinvatecTerminatedNov 19, 2012
Linvatec Corporation dba ConMed Linvatec in Largo, FL is recalling the S8580, 8.0MM SENTINEL Cannulated Drill Bit, lot numbers 322225 and 322226; and the S8585, 8.5MM SENTINEL Cannulated Drill Bit, lot number 322287. Recall was initiated due to the incorrect labeling on package.
- Linvatec Corp. dba ConMed LinvatecTerminatedNov 19, 2012
Linvatec Corporation dba ConMed Linvatec in Largo, FL is recalling the S8580, 8.0MM SENTINEL Cannulated Drill Bit, lot numbers 322225 and 322226; and the S8585, 8.5MM SENTINEL Cannulated Drill Bit, lot number 322287. Recall was initiated due to the incorrect labeling on package.
- Exactech, Inc.TerminatedSep 11, 2012
Exactech Inc. of Gainesville, FL is recalling their Novation Modular Drill Bits after the devices were reported to have been used by end user while in a non-sterile condition.
- Exactech, Inc.TerminatedSep 11, 2012
Exactech Inc. of Gainesville, FL is recalling their Novation Modular Drill Bits after the devices were reported to have been used by end user while in a non-sterile condition.
- Exactech, Inc.TerminatedSep 11, 2012
Exactech Inc. of Gainesville, FL is recalling their Novation Modular Drill Bits after the devices were reported to have been used by end user while in a non-sterile condition.
- Exactech, Inc.TerminatedSep 11, 2012
Exactech Inc. of Gainesville, FL is recalling their Novation Modular Drill Bits after the devices were reported to have been used by end user while in a non-sterile condition.
- Exactech, Inc.TerminatedSep 11, 2012
Exactech Inc. of Gainesville, FL is recalling their Novation Modular Drill Bits after the devices were reported to have been used by end user while in a non-sterile condition.
- Exactech, Inc.TerminatedSep 11, 2012
Exactech Inc. of Gainesville, FL is recalling their Novation Modular Drill Bits after the devices were reported to have been used by end user while in a non-sterile condition.
- The Anspach Effort, Inc.TerminatedJul 25, 2012
Anspach Effort, Inc. Palm Beach Gardens, FL is recalling their Single Use Sterile Bone Cutting Burrs used with XMax, microMax, microMax Plus, eMax, eMax2 and eMax2 Plus High Speed Drill Systems. It is possible for the cutter to come apart.
- Smith & Nephew IncTerminatedJun 6, 2012
Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility.
- Smith & Nephew IncTerminatedJun 6, 2012
Plastic trays which encase these products have burrs on the hinged packaging which can puncture the single barrier sterile pouch, voiding sterility.
- Interventional Spine IncTerminatedJan 11, 2012
The recall was intiated because Interventional Spine has confirmed that the PERPOS 2-in-1 Drill (6070) manufactured by a contract manufacturer for Interventional Spine, Inc., may break during use.
- Interventional Spine IncTerminatedJan 11, 2012
The recall was intiated because Interventional Spine has confirmed that the PERPOS 2-in-1 Drill (6070) manufactured by a contract manufacturer for Interventional Spine, Inc., may break during use.
- Synthes USA (HQ), Inc.TerminatedJan 11, 2012
Synthes is initiating a recall of the Drill Bit for 5.0mm Recon Screws with large Quick Coupling due to the potential for the drill stop to slip on the drill bit.
- Orthohelix Surgical Designs IncTerminatedApr 22, 2010
The epoxy is flaking off the drill bits and countersinks.
- Intelifuse IncTerminatedMar 5, 2009
Manufacturing specification for drill bit was incorrect which, when used in conjunction with the drill guide, could cause the production of metal shavings.
- Intelifuse IncTerminatedMar 5, 2009
Manufacturing specification for drill bit was incorrect which, when used in conjunction with the drill guide, could cause the production of metal shavings.
- Sterilmed IncTerminatedJan 13, 2009
SteriMed, Inc is conducting a product removal of a small group of devices individually packaged and sealed within a pouch. The removal is being conducted because the possibility exists that some of the pouches were not properly sealed on one end. A breach in packaging seal or a failure in packaging integrity has the possibility of risk to the patient in terms of transmitting organisms capable
- Integra LifeSciences Corp.TerminatedJan 9, 2007
Incorrect drill length-Cannulated drill bits were manufactured to incorrect specifications (shorter length) resulting in inadequate preparation of bone prior to insertion of the UNI-CLIP Staple.
- Stryker Howmedica OsteonicsTerminatedFeb 26, 2003
Certain sterile packed drills with center tip may penetrate the foam and blister resulting in loss of sterility.
- Stryker Howmedica OsteonicsTerminatedFeb 26, 2003
Certain sterile packed drills with center tip may penetrate the foam and blister resulting in loss of sterility.
- Stryker Howmedica OsteonicsTerminatedFeb 26, 2003
Certain sterile packed drills with center tip may penetrate the foam and blister resulting in loss of sterility.
- Stryker Howmedica OsteonicsTerminatedFeb 26, 2003
Certain sterile packed drills with center tip may penetrate the foam and blister resulting in loss of sterility.
- Stryker Howmedica OsteonicsTerminatedFeb 26, 2003
Certain sterile packed drills with center tip may penetrate the foam and blister resulting in loss of sterility.
- Stryker Howmedica OsteonicsTerminatedFeb 26, 2003
Certain sterile packed drills with center tip may penetrate the foam and blister resulting in loss of sterility.
- Stryker Howmedica OsteonicsTerminatedFeb 26, 2003
Certain sterile packed drills with center tip may penetrate the foam and blister resulting in loss of sterility.
- Flower Orthopedics CorporationTerminatedUnknown
Drill bits packaged in kits are missing the AO connect feature and may result in delay of procedure
- Flower Orthopedics CorporationTerminatedUnknown
Drill bits packaged in kits are missing the AO connect feature and may result in delay of procedure
- Flower Orthopedics CorporationTerminatedUnknown
Drill bits packaged in kits are missing the AO connect feature and may result in delay of procedure
- Flower Orthopedics CorporationTerminatedUnknown
Drill bits packaged in kits are missing the AO connect feature and may result in delay of procedure
- MicroAire Surgical Instruments, LLCTerminatedUnknown
One lot was found to contain both the correct twist drill (1.6mm) as well as an incorrect twist drill (2.0mm)
- AAP Implantate AgTerminatedUnknown
Products were distributed with the incorrect instructions for use.
- AAP Implantate AgTerminatedUnknown
Products were distributed with the incorrect instructions for use.
- Arthrex, Inc.TerminatedUnknown
The color indicator on the proximal end of the shaft of the AR-8770-02 is the incorrect color.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Zimmer GmbHTerminatedUnknown
An investigation identified that the products were possibly manufactured from a different material than defined in the applicable specifications.
- Tornier, IncTerminatedUnknown
Drill bit tips without new BargerGard tip protector may puncture through sterile packaging.
- Trilliant Surgical, LLCTerminatedUnknown
Labeling Error; specifically, drill bits from lots # TSL008495A are marked with the lot # of TSL008495. This could lead to parts being misidentified and impact device traceability.
- NEOSTEOTerminatedUnknown
Traces of corrosion on the laser marking was detected on cannulated graduated drill bit, which could lead to the emission of wear / corrosion particles in the operated area, potentially leading to the following risks: Inflammation, pain, allergy, adverse tissue reaction. Device description: The drill bit is used to create the hole required for the introduction of the screw, it is suitable for Neosteo compression screws for cortical and spongy bone. Drilling depth can be read on the instrument. The shaft is coupled with the 4.5mm surgical motor using a AO 4.5mm male drive connexion. The countersink bit is coupled to a 1.0mm k-wire to ensure guiding while drilling. The instrument is packaged in a plastic sheath sealed by welding.
- Paragon 28, Inc.TerminatedUnknown
A thin wall condition between the inner cannulation and the flutes of the drill which potentially could cause a fracture through the wall of the drill to the cannulation beneath.
- Cayenne Medical Inc.TerminatedUnknown
A review of complaints identified a trend for drills breaking.