Recalls for Radioimmunoassay, Free Thyroxine
12 on file
- Beckman Coulter Inc.TerminatedJun 2, 2020
The recalling firm characterized the potential interference effects of biotin (up to 1,200 ng/mL) on all biotin-mediated Access assays. The following six assays: Free T3-REF A13422, Total T3-REF 33830, Free T4-REF 33880, GI Mon-387687, Tg-REF 33860, and TgAbII-REF A32898 displayed significant interference (defined as a result bias greater than +/-10%) at 1,200 ng/mL of biotin.
- Siemens Healthcare Diagnostics, Inc.TerminatedMay 4, 2018
The concentrations for biotin listed in the non-interfering substances section of the instructions for use for the Dimension TSHL, Dimension LOCI FT4L, Dimension Vista TSH, ADVIA Centaur Cyclosporine, and ADVIA Centaur DHEAS, incorrectly state the level at which biotin does not interfere.
- Qualigen IncTerminatedDec 19, 2013
Qualigen initiated this recall because the FastPack kit may cause lower than expected results due to a manufacturing defect.
- Beckman Coulter Inc.TerminatedApr 11, 2011
The recall was initiated because the stability claim for Access Free T4 calibrator lot 014769 is not met. The affected T4 calibrator lot can produce quality control and patient results that are erroneously low (by greater than 2 standard deviations). An erroneously low patient result may lead to misdiagnosis and/or delayed treatment.
- Siemens Healthcare Diagnostics, Inc.TerminatedNov 24, 2010
Some LOCI cartridges have sub-optimal seal of the lidstock that can cause rupture of the package at high elevations, causing the cartridge to leak. Use of leaking cartridges may result in inaccurate test results.
- Beckman Coulter Inc.TerminatedOct 1, 2010
The recall was initiated after Beckman Coulter determined that kit boxes for Access Free T4 reagent (REF 33880), lot number 916293 may contain reagent packs labeled as Access Vitamin B12, (REF 33000), lot 916277. Using an Access Vitamin B12 reagent pack, lot 916277, filled with Access Free T4 reagents may generate incorrect patient results.
- Abbott Laboratories HPD/ADDTerminatedAug 13, 2003
The Free T4 Controls, may yield control values that are high and outside of the package insert ranges.
- Abbott Laboratories HPD/ADDTerminatedAug 13, 2003
The Free T4 Controls, may yield control values that are high and outside of the package insert ranges.
- Abbott Laboratories HPD/ADDTerminatedAug 13, 2003
The Free T4 Controls, may yield control values that are high and outside of the package insert ranges.
- Abbott Ireland Diagnostics DivisionTerminatedUnknown
Abbott has become aware of a manufacturing issue that can result in damage to a bottle neck in some of the reagent cartridges found in the lots listed in Appendix A. If a bottle neck is damaged, it may cause a failure during the reagent loading process on the Alinity i instrument.
- Tosoh Bioscience IncTerminatedUnknown
Asfotase Alfa (Strensiq) interferes with certain Tosoh assays which potentially causes falsely increased or falsely decreased immunoassay test results, depending upon the assay.
- Beckman Coulter Inc.TerminatedUnknown
The Access immunoassays are susceptible to biotin interference.