Ventilator, Emergency, Powered (resuscitator)
Anesthesiology · 21 CFR 868.5925
Recent MDR events
4,749 adverse event reports on file
- GIRAFFE IRSJul 22, 2026MalfunctionDatex-ohmeda, Inc.3036470679-2026-00115
- GIRAFFE IRSJul 22, 2026MalfunctionDatex-ohmeda, Inc.3036470679-2026-00116
- GIRAFFE IRSJul 22, 2026MalfunctionDatex-ohmeda, Inc.3036470679-2026-00118
- GIRAFFE IRSJul 22, 2026MalfunctionDatex-ohmeda, Inc.3036470679-2026-00117
- PANDAJul 17, 2026MalfunctionDatex-ohmeda, Inc.3036470679-2026-00113
- GIRAFFE IRSJul 8, 2026MalfunctionDatex-ohmeda, Inc.3036470679-2026-00104
- PNEUPAC PARAPAC PLUSJul 7, 2026MalfunctionIcu Medical Healthcare Manufacturing S.a. De C.v3012307300-2026-07072
- PNEUPAC PARAPAC PLUSJul 2, 2026MalfunctionIcu Medical Healthcare Manufacturing S.a. De C.v3012307300-2026-06805
- GIRAFFE IRSJul 1, 2026MalfunctionDatex-ohmeda, Inc.3036470679-2026-00101
- GIRAFFE IRSJul 1, 2026MalfunctionDatex-ohmeda, Inc.3036470679-2026-00102
Event type breakdown
Recalls
29 recall events for this product code
- Mercury Enterprises, Inc. dba Mercury MedicalOpen, ClassifiedJan 10, 2025
Neo-Tee T-Piece Resuscitator, for pediatric emergency respiratory support, Part: 1050805, 1050808, 1050809, 1050810, 1050811, 1050814, 1050832, 1050839, 1050840
Gas powered emergency resuscitator has a circuit flow controller manufactured with an undersized spring, which may cause resuscitator not reach the high and low ends of the PIP and PEEP pressure ranges, which may cause a loss of positive pressure, impacting effective ventilation of the patient.
Z-0821-2025 · View FDA record ↗ - Mercury Enterprises, Inc. dba Mercury MedicalOpen, ClassifiedOct 2, 2024
Neo-Tee T-Piece Resuscitator. Part Numbers 1050805, 1050832. For pediatric emergency respiratory support.
Manual resuscitator circuit flow controller may come apart due to a missing manufacturing step.
Z-0004-2025 · View FDA record ↗ - Smiths Medical ASD Inc.Open, ClassifiedSep 20, 2024
paraPAC plus 310 ventilator kit with internal PEEP and CPAP, Item Number P310N
Smiths Medical became aware of an issue related to a potential for the patient outlet connector to loosen/detach from the paraPAC Plus P300 and P310 ventilators impacting the active ventilation function.
Z-3090-2024 · View FDA record ↗ - Smiths Medical ASD Inc.Open, ClassifiedSep 20, 2024
paraPAC 300 ventilator kit without internal PEEP and CPAP, Item Number P300N
Smiths Medical became aware of an issue related to a potential for the patient outlet connector to loosen/detach from the paraPAC Plus P300 and P310 ventilators impacting the active ventilation function.
Z-3091-2024 · View FDA record ↗ - Smiths Medical ASD Inc.Open, ClassifiedSep 11, 2024
Pneupac paraPAC plus 300 ventilator kit, REF P300NXX
There is a potential for inadvertent tidal volume knob movement from the original setting when set at high (1000-1500 mL) and low (70-150 mL) settings.
Z-2973-2024 · View FDA record ↗ - Smiths Medical ASD Inc.Open, ClassifiedSep 11, 2024
Pneupac paraPAC plus 310 ventilator kit with PEEP and CPAP, REF P310NXX
There is a potential for inadvertent tidal volume knob movement from the original setting when set at high (1000-1500 mL) and low (70-150 mL) settings.
Z-2974-2024 · View FDA record ↗ - Smiths Medical ASD Inc.Open, ClassifiedMar 19, 2024
smiths medical Pneupac paraPAC plus 310 ventilator kit with PEEP and CPAP, REF P310NUS
When a paraPAC plus ventilator is switched to the operating mode of VENTILATE, the ventilator may intermittently provide continuous positive gas flow instead of the intended cycling like a human breath. This non-cycling and continuous positive gas flow when in the cycling mode, is a malfunction, not allowing the ventilator to properly function as designed.
Z-1274-2024 · View FDA record ↗ - Smiths Medical ASD Inc.Open, ClassifiedMar 19, 2024
smiths medical Pneupac paraPAC plus 300 ventilator kit without PEEP and CPAP, REF P300NUS
When a paraPAC plus ventilator is switched to the operating mode of VENTILATE, the ventilator may intermittently provide continuous positive gas flow instead of the intended cycling like a human breath. This non-cycling and continuous positive gas flow when in the cycling mode, is a malfunction, not allowing the ventilator to properly function as designed.
Z-1275-2024 · View FDA record ↗ - O-Two Medical Technologies, Inc.TerminatedApr 4, 2019
e500 Automatic Transport Ventilator, Model Number 01EVE500
There is a potential for the unit to catch fire due to one of the screen retaining screws being incorrectly inserted. Due to this improper screw insertion the screw sat higher than normal allowing it to contact the underside of the main board causing the screw to rub against the bottom side of the board, wearing away the insulation layer and creating a short circuit.
Z-0976-2019 · View FDA record ↗ - O-Two Medical Technologies, Inc.TerminatedApr 4, 2019
e600 Automatic Transport Ventilator, Model Number 01EVE600
There is a potential for the unit to catch fire due to one of the screen retaining screws being incorrectly inserted. Due to this improper screw insertion the screw sat higher than normal allowing it to contact the underside of the main board causing the screw to rub against the bottom side of the board, wearing away the insulation layer and creating a short circuit.
Z-0977-2019 · View FDA record ↗
Registered firms
82 firms currently registered for this product code
Weinmann Emergency Medical Technology Gmbh
Hamburg, DE
Sunmed Ap, Ltd.
ZHUHAI Guangdong, CN
Allied Medical Llc
Earth City, MO, US
Draegerwerk Ag & Co. Kgaa
LUEBECK Schleswig-Holstein, DE
Icu Medical, Inc.
SAN CLEMENTE, CA, US
O-two Medical Technologies, Inc.
Brampton Ontario, CA
Linamar Innovation Hub
Guelph Ontario, CA
Magnamed Tecnologia Medica S/a
Sao Paulo, BR
Cbr Enterprise Limited
Hong Kong, HK
Katmai Health Services Llc
Brilliant, OH, US
Ge Medical Systems Information Technologies - Critikon De Mexico S. De R.l. De C.v.
JUAREZ Chihuahua, MX
Icu Medical Nederland B.v.
Wijchen Gelderland, NL
510(k) clearances
100 clearances for this product code
- Draegerwerk AG & CO KgaaApr 4, 2025
K242769 · VentStar Resus heated (N) (MP17030); VentStar Autobreath heated (N) (MP17031)
- Magnamed Tecnologia Medica S/AMay 24, 2023
K221634 · Oxymag - Transport and Emergency Ventilator
- Vortran Medical Technology 1, Inc.Feb 11, 2021
K202219 · VORTRAN GO2VENT with PEEP Valve
- Weinmann Emergency Medical Technology GmbH + Co. KGNov 20, 2020
K193191 · MEDUMAT Easy CPR, MEDUMAT Easy CPR with bag
- International BiomedicalJan 18, 2019
K182956 · Puffin Lite Infant Resuscitation System
- Ventlab, LLCNov 16, 2018
K173373 · SafeT T-Piece Resuscitator
- Thornhill Research, Inc.Jun 6, 2017
K161420 · MOVES SLC
- Vortran Medical Technology 1, Inc.Apr 10, 2017
K162968 · VORTRAN GO2VENT