ACCELERATE PHENO SYSTEM, ACCELERATE PHENOTEST BC KIT
Received Oct 23, 2019 · Event occurred Sep 19, 2019
Report 3010671651-2019-00001 · MDR key 9227519
Device
Generic name
Accelerate Pheno¿ System
Manufacturer
Accelerate Diagnostics, Inc.Model number
10401008Catalog number
10101018
Lot number
3715A
Product problems
- Adverse Event Without Identified Device or Use Problem
- Adverse Event Without Identified Device or Use Problem
Patient
46 YR
- Therapeutic Response, Increased
- No Known Impact Or Consequence To Patient
- Therapeutic Response, Increased
- No Known Impact Or Consequence To Patient
Narrative
Additional Manufacturer Narrative
THE ACCELERATE PHENO¿ SYSTEM IS A FULLY-INTEGRATED IN VITRO DIAGNOSTIC SYSTEM COMPRISED OF ONE TO EIGHT ID/AST MODULE(S), A COMPUTING SYSTEM, TOUCHSCREEN MONITOR AND ACCELERATE PHENO¿ SYSTEM SOFTWARE FOR USE WITH ACCELERATE PHENOTEST¿ KITS. IT IS DESIGNED TO PERFORM IDENTIFICATION (ID) OF BACTERIAL AND YEAST CELLS AND ANTIMICROBIAL SUSCEPTIBILITY TESTING (AST) IN APPROXIMATELY 7 HOURS DIRECTLY FROM POSITIVE BLOOD CULTURE SAMPLES. ACCELERATE DIAGNOSTICS OPENED AN INVESTIGATION AFTER RECEIVING A COMPLAINT. RUN DATA AND IMAGES OBTAINED FROM THE ACCELERATE PHENO¿ SYSTEM RUN IN QUESTION WERE REVIEWED. THE CONCLUSION WAS THAT THE SAMPLE CONTAINED A HIGH AMOUNT OF DEBRIS IN THE PSEUDOMONAS AERUGINOSA (PAE) CHANNEL AND VERY FEW RODS WERE OBSERVED IN THE ESCHERICHIA COLI CHANNEL (BELOW THE LIMIT OF DETECTION). AS PART OF THE INVESTIGATION, THE SAMPLE WAS SENT TO ACCELERATE DIAGNOSTICS, INC. FOR DISCREPANCY TESTING. TESTING WAS COMPLETED USING MALD-TOF, AND RESULTS CONFIRMED THE SAMPLE CONTAINED ESCHERICHIA COLI ONLY. NEGATIVE SAMPLE TESTING WAS ALSO PERFORMED TO DETERMINE IF THE PAE PROBE CONTAINS DEBRIS THAT COULD CAUSE FALSE POSITIVE RESULTS. NEGATIVE SAMPLE TESTING DEMONSTRATED THAT THE PROBE DOES NOT CONTAIN DEBRIS. ROOT CAUSE OF THE FALSE-POSITIVE PAE WAS DETERMINED TO BE DEBRIS IN THE PAE CHANNEL, YET CAUSE OF THE DEBRIS CANNOT BE DETERMINED. FALSE POSITIVES ARE INHERENT TO THE DEVICE AND INCLUDED IN THE LABELING.
Description of Event or Problem
THE ACCELERATE PHENO¿ SYSTEM REPORTED PSEUDOMONAS AERUGINOSA (FALSE POSITIVE). THE PATIENT RECEIVED AN ESCALATION OF ANTIBIOTICS, AN ID CONSULT, AND CT CHEST/ABDOMEN/PELVIS TO IDENTIFY THE SOURCE OF THE INFECTION. THE COMPARATOR METHOD (MALDI-TOF) IDENTIFIED ESCHERICHIA COLI. A PATIENT ADMITTED WITH ASCENDING CHOLANGITIS HAD BLOOD CULTURES TAKEN FOR IDENTIFICATION (ID)AND ANTIMICROBIAL SUSCEPTIBILITY TESTING (AST). THE ACCELERATE PHENO¿ SYSTEM ID RESULT INDICATED THAT THE PATIENT WAS INFECTED WITH DRUG-RESISTANT PSEUDOMONAS AERUGINOSA. IN RESPONSE, ANTIBIOTIC TREATMENT WAS ESCALATED USING CEFEPIME, AN ID CONSULT WAS INITIATED, AND THE PATIENT RECEIVED A CT CHEST/ABDOMEN/PELVIS TO IDENTIFY THE SOURCE OF THE PAE INFECTION AND DETERMINE WHETHER IT WAS PRESENT ON THE PATIENT'S SPINAL HARDWARE. AFTER 24 HOURS, COMPARATIVE TEST (MALD-TOF) RESULTS IDENTIFIED THE BACTERIA AS ESCHERICHIA COLI, NOT PSEUDOMONAS AERUGINOSA. PATIENT THERAPY WAS THEN DEESCALATED TO ORAL CIPROFLOXACIN. THE PATIENT RESPONDED WELL AND WAS DISCHARGED ON THE ORAL CIPROFLOXACIN.