ORALBPWRBATTTOOTHBRUSHHANDLECROSSACTNPWR4732
Received Apr 30, 2019
Report 3000302531-2019-00075 · MDR key 8566226
Device
Generic name
Toothbrush, Powered
Manufacturer
Braun Gmbh Werk MarktheidenfeldModel number
4732Lot number
NOT AVAILABLE
Product problems
- Break
- Detachment of Device or Device Component
Patient
Not reported
- Foreign Body In Patient
- Foreign Body In Patient
Narrative
Additional Manufacturer Narrative
PRODUCT RETURN WAS NOT RECEIVED. PRODUCT RETURN WAS REQUESTED. FULL EVALUATION WILL OCCUR UPON RECEIPT OF RETURNED PRODUCT.
Description of Event or Problem
DISCONNECTED BRUSH HEAD LODGING TOWARD BACK OF THROAT [FOREIGN BODY IN RESPIRATORY TRACT]. HEADS DISCONNECTING FROM THE TOOTHBRUSH [DEVICE BREAKAGE]. THE NIPPLE AT THE END OF THE PORTION THAT SLIDES INTO THE TOOTHBRUSH AND IS SUPPOSED TO LOCK THE HEAD ONTO THE TOOTHBRUSH IN INSUFFICIENT TO DO SO / NIPPLE WILL NOT KEEP THE HEAD LOCKED ONTO THE TOOTHBRUSH [DEVICE CONNECTION ISSUE]. CONSUMER E-MAILED AND STATED THAT HE/SHE HAD A PROBLEM OF THE TOOTHBRUSH HEADS DISCONNECTING FROM THE TOOTHBRUSH. NO SERIOUS INJURY WAS REPORTED.
Description of Event or Problem
DISCONNECTED BRUSH HEAD LODGING TOWARD BACK OF THROAT [FOREIGN BODY IN RESPIRATORY TRACT]. HEADS DISCONNECTING FROM THE TOOTHBRUSH [DEVICE BREAKAGE] THE NIPPLE AT THE END OF THE PORTION THAT SLIDES INTO THE TOOTHBRUSH AND IS SUPPOSED TO LOCK THE HEAD ONTO THE TOOTHBRUSH IN INSUFFICIENT TO DO SO / NIPPLE WILL NOT KEEP THE HEAD LOCKED ONTO THE TOOTHBRUSH [DEVICE CONNECTION ISSUE] CONSUMER E-MAILED AND STATED THAT HE/SHE HAD A PROBLEM OF THE TOOTHBRUSH HEADS DISCONNECTING FROM THE TOOTHBRUSH. NO SERIOUS INJURY WAS REPORTED.
Additional Manufacturer Narrative
PRODUCT RETURN WAS RECEIVED ON 28-MAY-2019 AND IDENTIFIED AS AN ORAL-B POWER BATTERY TOOTHBRUSH HANDLE CROSS ACTION POWER 4732 ON 05-JUN-2019. PRODUCT INVESTIGATION IS IN PROGRESS.