inforMED
InjuryGCZ

ETHILOOP SILICON SLING UNKNOWN PRODUCT

Received Oct 11, 2018

Report 2210968-2018-76469 · MDR key 7957145

Device

Generic name

Retainer, Surgical

Manufacturer

Ethicon Inc.

Catalog number

UNK

Lot number

UNK

Product problems

  • Adverse Event Without Identified Device or Use Problem
  • Adverse Event Without Identified Device or Use Problem

Patient

Not reported

  • Wound Dehiscence
  • Sepsis
  • Not Applicable
  • Wound Dehiscence
  • Sepsis
  • Not Applicable

Narrative

Additional Manufacturer Narrative

(B)(4). THIS REPORT IS RELATED TO A JOURNAL ARTICLE, THEREFORE NO PRODUCT WILL BE RETURNED FOR ANALYSIS AND THE BATCH HISTORY RECORDS CANNOT BE REVIEWED AS THE LOT NUMBER HAS NOT BEEN PROVIDED. CITATION: ARCH SURG/VOL 146 (NO. 6), JUNE 2011. (B)(4).

Description of Event or Problem

IT WAS REPORTED VIA JOURNAL ARTICLE: "TITLE: DYNAMIC PARIETAL CLOSURE: INITIAL EXPERIENCE OF AN ORIGINAL PARIETAL CLOSURE PROCEDURE FOR TREATMENT OF ABDOMINAL WOUND DEHISCENCE" AUTHORS: QUENTIN QASSEMYAR, MD, FRANC¸OIS BROWET, MD, MICHELINE ROBBE, MD, PHD, PIERRE VERHAEGHE, MD, PHD AND JEAN-MARC REGIMBEAU, MD, PHD. CITATION: ARCH SURG/VOL 146 (NO. 6), JUNE 2011. THE AIM OF THIS PAPER WAS TO DISCUSS THE AUTHORS¿ DEVELOPED ¿DYNAMIC PARIETAL CLOSURE¿ TECHNIQUE IN WHICH SILICONE LOOP SUTURES WERE USED TO STRENGTHEN A CONVENTIONAL APONEUROTIC CLOSURE. THE PROCEDURE WAS SIMPLE, QUICK, INEXPENSIVE, AND COMPATIBLE WITH DIGESTIVE STOMAS AND COMPLEX PERITONEAL DRAINAGE. IT HAS THE ADVANTAGES BUT NOT THE DISADVANTAGES OF THE USE OF RETENTION SUTURES OR ABDOMINAL WALL PLASTIC SURGERY. FROM JANUARY 2009 TO DECEMBER 2010, THE AUTHORS PERFORMED A PROSPECTIVE STUDY OF 873 CONSECUTIVE PATIENTS WHO UNDERWENT A MIDLINE LAPAROTOMY. DURING THE PROCEDURE, AT THE TIME OF PARIETAL CLOSURE, SUCCESSIVE MASS CLOSURES WERE PERFORMED ALONG THE ENTIRE LENGTH OF THE MEDIAN LAPAROTOMY WITH ELASTIC SILICONE LOOPS (45 CM IN LENGTH AND 2MMIN DIAMETER [ETHILOOP; ETHICON, (B)(4)]). EACH LOOP WAS SCREWED ONTO THE PROXIMAL END OF A NEEDLE (AS IN DRAIN EXTERNALIZATION) AND WAS PLACED TRANSFASCIALLY ACROSS THE WOUND TO OBTAIN A U-SHAPED SUTURE EVERY 4 CM. THE INCISIONS WERE CLOSED BY A CONTINUOUS, APONEUROTIC SUTURE (PDS; ETHICON, SOMERVILLE, NEW JERSEY). THE SKIN WAS CLOSED CONVENTIONALLY. LASTLY, THE DYNAMIC PARIETAL CLOSURE¿S TENSION WAS ADJUSTED, AND COMPRESSES WERE PLACED BETWEEN THE SKIN AND THE LOOPS. THE OVERALL INCIDENCE RATE FOR ABDOMINAL WOUND DEHISCENCE (DIAGNOSED CLINICALLY WITHIN 2 WEEKS OF THE OPERATION) WAS (N=16). THE ETIOLOGY OF ABDOMINAL WOUND DEHISCENCE WAS MECHANICAL IN 12 PATIENTS AND SEPTIC IN 4 PATIENTS. THE ABDOMINAL WOUND DEHISCENCE RECURRENCE RATE WAS 0%. ALL CASES OF ABDOMINAL WOUND DEHISCENCE PERFORMED AN EMERGENCY PROCEDURE TO REDO THE MIDLINE LAPAROTOMY, EXAMINE THE ABDOMINAL CAVITY (TO CHECK FOR INFECTION), AND THEN PERFORM THE DYNAMIC PARIETAL CLOSURE TECHNIQUE. IN CONCLUSION, DYNAMIC PARIETAL CLOSURE IS AN ORIGINAL, EASY, INEXPENSIVE, AND EFFICIENT PROCEDURE. IT MUST BE EVALUATED WITH LARGER NUMBERS OF PATIENTS. IN INDIVIDUALS WITH A VERY HIGH RISK OF ABDOMINAL WOUND DEHISCENCE, THE DYNAMIC PARIETAL CLOSURE TECHNIQUE COULD PERHAPS BE PERFORMED PREVENTIVELY.