COUNTERSINK
Received Aug 15, 2016
Report 2520274-2016-14101 · MDR key 5877578
Device
Generic name
Countersink
Manufacturer
Synthes UsaProduct problems
- Adverse Event Without Identified Device or Use Problem
- Adverse Event Without Identified Device or Use Problem
Patient
Not reported
- Unspecified Infection
- Unspecified Infection
Narrative
Additional Manufacturer Narrative
DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. ARTHROSCOPIC RECONSTRUCTION OF THE ANTERIOR CRUCIATE LIGAMENT WITH PATELLAR-TENDON AUTOGRAFT AND INTERFERENCE SCREW FIXATION. THE JOURNAL OF BONE AND JOINT SURGERY. (1999) 81-B: 775 TO 779. THIS REPORT IS FOR UNKNOWN SCREW /UNKNOWN QUANTITY/ UNKNOWN LOT. THE INVESTIGATION COULD NOT BE COMPLETED AND NO CONCLUSION COULD BE DRAWN, AS NO DEVICE WAS RETURNED AND NO LOT NUMBER OR PART NUMBER WAS PROVIDED. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.
Description of Event or Problem
THIS REPORT IS BEING FILED AFTER THE SUBSEQUENT REVIEW OF THE FOLLOWING LITERATURE ARTICLE: JOMHA, N. M., PINCZEWSKI, A. L., CLINGELEFFER, A., OTTO, D.D. (1999). ARTHROSCOPIC RECONSTRUCTION OF THE ANTERIOR CRUCIATE LIGAMENT WITH PATELLAR-TENDON AUTOGRAFT AND INTERFERENCE SCREW FIXATION. THE JOURNAL OF BONE AND JOINT SURGERY. 81-B: 775 TO 779, AUSTRALIA. THIS ARTICLE PROVIDES A DISCUSSION INVOLVING 59 PATIENTS WHO HAD UNDERGONE AN ARTHROSCOPIC RECONSTRUCTION OF THE ANTERIOR CRUCIATE LIGAMENT (ACL) USING A CENTRAL-THIRD PATELLAR-TENDON AUTOGRAFT FOR SEVEN YEARS. IN ALL OPERATIONS, THE SAME TECHNIQUE WAS USED, WHICH INVOLVED A CENTRAL-THIRD PATELLAR-TENDON AUTOGRAFT WITH BONE BLOCKS TAKEN FROM THE IPSILATERAL KNEE AND INSERTED THROUGH HOLES DRILLED IN THE TIBIA AND FEMUR. AO 6.5 MM FULLY THREADED CANCELLOUS SCREWS ACHIEVED INTERFERENCE FIXATION. WHERE THERE WAS ABNORMAL MEDIAL COLLATERAL LIGAMENT (MCL) LAXITY, THE PROXIMAL LIGAMENT WAS ADVANCED JUST BEFORE FIXATION OF THE ACL GRAFT TO THE TIBIA, AND FIXED WITH A STAPLE. POST-OPERATIVELY, PATIENTS WERE INFUSED INTRAVENOUSLY WITH ANTIBIOTICS FOR 24 HOURS AND KNEES WERE SUBJECTED TO CONTINUOUS PASSIVE MOTION FROM 30 DEGREES TO 90 DEGREES FOR 48 HOURS. PATIENTS WERE ALSO NON-WEIGHT BEARING IN A REHABILITATION BRACE (30 DEGREES TO 90 DEGREES) FOR FOUR WEEKS. WOUND INSPECTION OCCURRED DAILY AND SUTURES WERE REMOVED 10 TO 14 DAYS AFTER SURGERY. ADDITIONAL FOLLOW-UPS WERE PERFORMED UP TO 7 YEARS. COMPLICATIONS: SCREWS WERE REMOVED IN SEVEN CASES AND ONE REPORTED POST-OPERATIVE INFECTION (TREATED BY LAVAGE AND REMOVAL OF SCREW). THIS IS REPORT 1 OF 1 FOR (B)(4). THIS REPORT IS FOR AN UNKNOWN AO SCREW.
Additional Manufacturer Narrative
DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.