Device
Generic name
Gelsoft Gelatin Impregnated Knitted Vascular Prosthesis
Manufacturer
Vascutek LtdModel number
GELSOFT BIFURCATECatalog number
631407
Lot number
323516
Product problems
- Device Operates Differently Than Expected
- Device Operates Differently Than Expected
Patient
48 YR
- No Code Available
- No Code Available
Narrative
Additional Manufacturer Narrative
DEVICE DISCARDED BY HOSPITAL - NOT RETURNED TO MAUFACTURER. (B)(4). METHOD: PROCESS EVALUATION - REVIEW OF RETAINED QC AND MANUFACTURING RECORDS; MANUFACTURING REVIEW - REVIEW OF RETAINED QC AND MANUFACTURING RECORDS; STERILISATION REVIEW. - REVIEW OF STERILISATION CYCLE; ACTUAL DEVICE NOT EVALUATED - DEVICE DISCARDED BY HOSPITAL. RESULT: NO ISSUES WERE FOUND WITH BATCH MANUFACTURE , QC INSPECTION OR STERILISATION PROCESS. CONCLUSION: UNABLE TO CONFIRM COMPLAINT - WITHOUT RETURN OF DEVICE OR SAMPLE OF SERUM VASCUTEK WAS UNABLE TO INVESTIGATE FURTHER TO CONFIRM COMPLAINT; DEVICE NOT RETURNED - NO DEVICE WAS RETURNED FOR INVESTIGATION THEREFORE UNABLE TO INVESTIGATE FURTHER. A PERIGRAFT SEROMA IS A STERILE COLLECTION OF CLEAR FLUID WITH A NON-SECRETORY PSUEDOMEMBRANE SURROUNDING A PROSTHETIC VASCULAR GRAFT . THE AETIOLOGY IS UNKNOWN BUT MAY RELATE TO RELATIVE FIBROBLAST INHIBITION, WITH FAILURE OF GRAFT INCORPORATION INTO SURROUNDING TISSUES. TREATMENTS HAVE INCLUDED OBSERVATION ALONE, MULTIPLE ASPIRATIONS, GRAFT REMOVAL, INJECTION OF PERIGRAFT SCLEROSING AGENTS, EXCISION OF THE FIBROUS PSEUDOCAPSULE, OR INTRAPERITONEAL DRAINAGE. IT IS CLEAR THAT THE CAUSATIVE FACTORS IN PERI-GRAFT SEROMA ARE UNCLEAR. A REVIEW OF CLINICAL PAPERS RELATED TO SEROMA HAS BEEN CARRIED OUT. IN A 14 YEAR RETROSPECTIVE STUDY OF PERIGRAFT SEROMA BY (B)(4) THEY OBSERVED POST OPERATIVE RATES OF SEROMA FORMATION BETWEEN 0.3% TO 4.2% IN A MIXTURE OF DACRON AND PTFE GRAFTS. SERA WAS TAKEN FROM THREE PATIENTS WITH PERIGRAFT SEROMA AND FROM FIVE PATIENTS WITH WELL INCORPORATED GRAFTS AND THREE HEALTHY VOLUNTEER SUBJECTS AND TESTED FOR FIBROBLAST INHIBITION. ONLY THE PATIENTS WITH PERIGRAFT SEROMA EXHIBITED INHIBITED FIBROBLAST FORMATION. THEY CONCLUDED THAT PERIGRAFT SEROMA APPEARS TO INVOLVE A HUMORAL FIBROBLAST INHIBITOR WHICH PREVENTS MATURATION AND PROLIFERATION OF PERIGRAFT FIBROBLASTS LEADING TO POOR INCORPORATION. (B)(4) REPORTED A RELATIVELY HIGH LEVEL OF POST-OPERATIVE SEROMA FORMATION IN UP TO 25% OF PATIENTS. THE ASSOCIATION OF SEROMA WITH IMPLANT LOCATION RATHER THAN THE GRAFT WAS ALSO SHOWN BY(B)(4). A COLLECTION OF CLEAR, STERILE FLUID, CONFINED WITHIN A NONSECRETORY FIBROUS PSEUDOMEMBRANE SURROUNDING A VASCULAR GRAFT, IS A SPECIFIC CLINICOPATHOLOGIC ENTITY TERMED PERIGRAFT SEROMA. A COMPREHENSIVE SURVEY, INCLUDING THE ENTIRE (B)(6), PROVIDED 279 CASES FOR DETAILED ANALYSIS. MATERIAL MOST COMMONLY INVOLVED WERE KNITTED DACRON (54%) AND POLYTETRAFLUORETHYLENE (34%), WITH KNITTED DACRON IN THE AXILLOFEMORAL POSITION ACCOUNTING FOR 31% OF THE CASES. IT IS ALSO POSSIBLE THAT SOME ABNORMALITY IN THE HEALING PROCESS ALLOWS SERUM TO PERMEATE THROUGH THE GRAFT WALL. (B)(4) FOUND THAT SEROMA FLUID INHIBITED FIBROBLAST GROWTH. THE AUTHORS STATED THAT DIFFERENT THEORIES HAVE BEEN POSTULATED IN THE LAST 10 YEARS IN AN ATTEMPT TO EXPLAIN THE PATHOGENETIC MECHANISMS INVOLVED IN PERIGRAFT SEROMA FORMATION.THE FINDINGS SUGGESTED THAT A PERIGRAFT SEROMA MAY REPRESENT A COMPLEX PHENOMENON WHICH CANNOT BE EXPLAINED EXCLUSIVELY IN TERMS OF FIBROBLAST STIMULATION OR INHIBITION. PERIGRAFT SEROMA: CLINICAL, HISTOLOGIC AND SEROLOGIC CORRELATES. AHN ET AL, AM J SURG. 1987 AUG; 154(2): 173-8; EUROPEAN PROSPECTIVE RANDOMISED MULTI-CENTRE AXILLIO-BIFEMORAL TRIAL. C.H. A. WITTENS ET AL. EUR J VASC SURGERY 6, 115-123(1992); PERIGRAFT SEROMAS COMPLICATING ARTERIAL GRAFTS. BLUMENBERG ET AL. SURGERY ST LOUIS VOL 97 NO.2 PP 194-203(1985); EFFECT OF PERIGRAFT SEROMA FLUID ON FIBROBLAST PROLIFERATION IN VITRO. V E PRICOLO ET AL. ANN VASC SURG. 1991 SEP;5(5):462-6. ALL 6 EVENTS REPORTED FROM THIS SITE ARE FROM A VARIETY OF PRODUCTS AND SIZES(GELSOFT STRAIGHTS,GELSOFT BIFURCATES, GELSOFT PLUS STRAIGHTS). THESE BATCHES WERE MANUFACTURED OVER A PERIOD OF ALMOST 2 YEARS ( AUG 2013 - JUL-2015) ALL BUT TWO ( (B)(4)) USED DIFFERENT BASE MATERIAL BATCHES. NONE OF THE COMPLAINT BATCHES WERE GELATIN IMPREGNATED ON THE SAME DATE AND ALL WERE STERILISED IN DIFFERENT CYCLES. NO FURTHER COMPLAINTS HAVE BEEN REPORTED RELATED TO THESE BATCHES OR STERILISATION CYCLES TO DATE. IN CONCLUSION THE ONLY COMMONALITY IN THESE EVENTS IS THE SITE REPORTED FROM. WITHOUT THE RETURN OF THE GRAFT FOR ANALYSIS VASCUTEK ARE UNABLE TO DETERMINE A DEFINITIVE ROOT CAUSE OF THIS EVENT HOWEVER FROM A REVIEW OF VASCUTEK'S CLINICAL EVALUATION REPORT FOR POLYESTER VASCULAR GRAFTS AND A REVIEW OF RELEVANT CLINICAL PAPERS IT HAS BEEN NOTED THAT SEROMA FORMATION IS A KNOWN AND EXPECTED COMPLICATION OF THIS TYPE OF PROCEDURE. (B)(4). ON THIS BASIS VASCUTEK NOW CONSIDERS THIS COMPLAINT CLOSED. HOWEVER THIS ISSUE WILL BE TRACKED AND TRENDED AS PART OF THE ROUTINE COMPLAINTS MONITORING AND REPORTING PROCESS. IF AN ADVERSE TREND DEVELOPS ACTIONS WILL BE TAKEN AT THAT TIME.
Description of Event or Problem
1 OF 6 EVENTS REPORTED FROM (B)(6) RELATING TO SEROMA FORMATION AROUND IMPLANTED GRAFT.