STENT
Received Jul 21, 2026
Report 2032493-2026-08085 · MDR key 25899001
Device
Generic name
Intracranial Coil-assist Stent
Manufacturer
Microvention, Inc.Product problems
- Adverse Event Without Identified Device or Use Problem
Patient
Not reported
- Extravasation
- Ruptured Aneurysm
Narrative
Description of Event or Problem
IT WAS REPORTED THAT AN EVENT OCCURRED DURING AN ELECTIVE CASE FOR AN UNRUPTURED L BILOBED ACOMM ANEURYSM. PRE-PROCEDURE CT AND MRI DEMONSTRATED NO EVIDENCE OF RUPTURE OR BLEEDING. PATIENT¿S HEADACHE WAS NOTED TO BE BETTER. RIGHT TF ACCESS WAS OBTAINED. A MICROCATHETER WAS USED FOR STENT-ASSISTED TREATMENT WITH A 4.5 X 25 LVIS EVO STENT. THE STENT WAS DEPLOYED. WHILE TRYING TO REMOVE THE COILS, ACCESS WAS LOST. THE PHYSICIAN ATTEMPTED TO DEPLOY AN ATLAS DEVICE. WITH THE SAME MICROWIRE, THE PHYSICIAN TRIED TO ACCESS THE LVIS EVO. FINAL ANGIOGRAPHY DEMONSTRATED EXTRAVASATION AND HAD AN INTRAOPERATIVE RUPTURE. AN EVD WAS PLACED. THE PATIENT WAS EXTUBATED 48 HOURS POST-PROCEDURE AND PLACED ON DAPT FOR THREE DAYS. THE PATIENT WAS DISCHARGED ON POST-OPERATIVE DAY 25 AND WAS NOTED TO BE IN GOOD CONDITION.
Additional Manufacturer Narrative
INVESTIGATION FINDINGS: WITHOUT THE RETURN AND PHYSICAL EVALUATION OF THE DEVICE, THE INVESTIGATION CANNOT FURTHER EXAMINE IF A CONDITION EXISTED THAT WOULD HAVE CONTRIBUTED TO THE REPORTED EVENT. WITHOUT IMAGING, THE INVESTIGATION CANNOT FURTHER VERIFY IF THE EVENT OCCURRED AS DESCRIBED, NOR COULD THE INVESTIGATION FURTHER EVALUATE THE CAUSE OF THE REPORTED EVENT. BASED ON A REVIEW OF THE DEVICE¿S RISK DOCUMENTATION, THE REPORTED EVENT DID NOT INDICATE THERE WERE THE PRESENCE OF ANY POTENTIAL OR NEW MANUFACTURING, DESIGN, QUALITY, OR OTHER SYSTEMIC ISSUES, OR NON-CONFORMANCES. THE COMPLAINT CODE IS MONITORED THROUGH THE TRENDING PROCESS; CORRECTIVE ACTION IS DETERMINED, AS NEEDED, THROUGH THIS PROCESS. INVESTIGATIONS OF HISTORIC COMPLAINT FILES WITH SIMILAR COMPLAINT CATEGORY CODING ARE RECORDED IN THE COMPLAINT HANDLING SYSTEM; WITHOUT THE ABILITY TO PERFORM AN ANALYSIS OF THE DEVICE, THIS INVESTIGATION CANNOT IDENTIFY WITH CERTAINTY ANY POTENTIAL ROOT CAUSES. BATCH REVIEW: A SEARCH FOR NON-CONFORMANCES ASSOCIATED WITH THIS PART/LOT NUMBER COMBINATION COULD NOT BE PERFORMED AS THIS INFORMATION WAS NOT AVAILABLE AT THE TIME THIS INVESTIGATION WAS PERFORMED. COMPLAINT SYSTEM REVIEW: A SEARCH OF THE COMPLAINT HANDLING SYSTEM COULD NOT BE PERFORMED TO DETERMINE IF OTHER SIMILAR COMPLAINTS EXIST FOR THIS BATCH NUMBER, BECAUSE THE BATCH NUMBER WAS NOT PROVIDED FOR THE PRODUCT ON THIS COMPLAINT FILE. IFU REVIEW (ADDITIONAL INFORMATION CAN BE FOUND IN THE IFU): POTENTIAL ADVERSE EVENTS THE FOLLOWING POTENTIAL RISKS AND COMPLICATIONS ASSOCIATED WITH GENERAL ANESTHESIA, CEREBRAL ANGIOGRAPHY, INTRACRANIAL CATHETERIZATION, INTRACRANIAL STENT PLACEMENT OR INTRA-SACCULAR COIL DEPLOYMENT HAVE BEEN IDENTIFIED BELOW: ALLERGIC REACTION, INCLUDING BUT NOT LIMITED TO: CONTRAST DYE, NITINOL METAL, AND ANY OTHER MEDICATIONS USED DURING THE PROCEDURE; APHASIA BLINDNESS; CARDIAC ARRHYTHMIA; COIL PROLAPSED OR MIGRATION INTO NORMAL VESSEL ADJACENT TO ANEURYSM COMPLICATIONS OF ARTERIAL PUNCTURE INCLUDING PAIN, LOCAL BLEEDING, LOCAL INFECTION AND INJURY TO THE ARTERY, VEIN OR ADJACENT NERVES; CRANIAL NEUROPATHY; DEATH; DEVICE FRACTURE, MIGRATION OR MISPLACEMENT; DISSECTION OR PERFORATION OF THE PARENT ARTERY; HEADACHE; HEMORRHAGE (I.E., INTRACEREBRAL HEMORRHAGE (ICH), SUBARCHNOID HEMORRHAGE (SAH), OR RETROPERITONEAL (OR IN OTHER LOCATIONS)); HEMIPLEGIA; HYDROCEPHALUS; INFECTION; INJURY TO NORMAL VESSEL OR TISSUE; ISCHEMIA; MASS EFFECT; MYOCARDIAL INFARCTION; NEUROLOGICAL DEFICITS; OCCLUSION OF NON-TARGET SIDE BRANCHES; PSEUDO ANEURYSM FORMATION; REACTIONS TO ANTI-PLATELET/ANTI-COAGULANT AGENTS; REACTIONS DUE TO RADIATION EXPOSURE; REACTIONS TO ANESTHESIA AND RELATED PROCEDURES; REACTIONS TO CONTRAST AGENTS; RENAL FAILURE; ANEURYSM RUPTURE; STENOSIS OF STENTED SEGMENT; SEIZURE; STENT THROMBOSIS; STROKE OR TIA (TRANSIENT ISCHEMIC ATTACK); THROMBOEMBOLIC EVENT (T/E); VASOSPASM; VISUAL IMPAIRMENT. WARNINGS: SHOULD UNUSUAL RESISTANCE BE FELT AT ANY TIME DURING ACCESS OR REMOVAL, THE INTRODUCER/GUIDE CATHETER/MICROCATHETER AND LVIS DEVICE SHOULD BE REMOVED AS A SINGLE UNIT. APPLYING EXCESSIVE FORCE DURING DELIVERY OR RETRIEVAL OF THE LVIS DEVICE CAN POTENTIALLY RESULT IN LOSS OR DAMAGE TO THE DEVICE AND DELIVERY COMPONENTS. IT IS IMPERATIVE TO USE THE LVIS DEVICE WITH COMPATIBLE MICROCATHETERS OR OCCLUSION BALLOONS. IF REPEATED FRICTION IS ENCOUNTERED DURING LVIS DEVICE DELIVERY, VERIFY MICROCATHETER IS NOT KINKED OR IN EXTREMELY TORTUOUS ANATOMY. CONFIRM THAT THE MICROCATHETER DOES NOT OVALIZE. CONFIRM THAT THERE IS ADEQUATE STERILE FLUSH SOLUTION. DO NOT REPOSITION THE LVIS DEVICE IN THE PARENT VESSEL WITHOUT FULLY RETRIEVING THE DEVICE. THE LVIS DEVICE MUST BE RETRIEVED INTO THE MICROCATHETER AND RE-DEPLOYED AT THE DESIRED TARGET LOCATION OR REMOVED COMPLETELY FROM THE PATIENT. PRECAUTIONS : EXERCISE CAUTION WHEN CROSSING THE DEPLOYED/DETACHED LVIS DEVICE WITH ADJUNCTIVE DEVICES SUCH AS GUIDEWIRES, CATHETERS, MICROCATHETERS OR BALLOON CATHETERS TO AVOID DISRUPTING THE DEVICE GEOMETRY AND DEVICE PLACEMENT. DIRECTIONS FOR USE 15. ADVANCE THE DELIVERY WIRE TO TRANSFER THE LVIS DEVICE FROM WITHIN THE INTRODUCER INTO THE MICROCATHETER. WARNING: DO NOT TORQUE THE DELIVERY WIRE WHILE ADVANCING OR RETRACTING THE LVIS DEVICE. A TORQUE DEVICE SHOULD NOT BE USED. 16. CONTINUE ADVANCING THE DELIVERY WIRE INTO THE MICROCATHETER UNTIL THE PROXIMAL TIP OF THE DELIVERY WIRE ENTERS THE INTRODUCER. LOOSEN THE RHV LOCKING RING, REMOVE THE INTRODUCER, AND SET IT ASIDE. WARNING: DO NOT APPLY UNDUE FORCE. IF RESISTANCE IS ENCOUNTERED AT ANY POINT DURING LVIS DEVICE DELIVERY OR MANIPULATION, WITHDRAW THE UNIT AND SELECT A NEW LVIS DEVICE. 18. POSITION THE LVIS DEVICE FOR DEPLOYMENT BY ALIGNING THE LVIS IMPLANT DISTAL RADIOPAQUE END MARKERS APPROXIMATELY 7 MM PAST THE ANEURYSM NECK. NOTE: A PROPER PUSH/PULL TECHNIQUE, ENCOMPASSING SUFFICIENT DELIVERY WIRE PUSH FORCE, IN ADDITION TO AN OPPOSING MICROCATHETER WITHDRAWAL FORCE, WILL FACILITATE PROPERLY DEPLOYING THE LVIS DEVICE TO ACHIEVE FULL EXPANSION AND GOOD VESSEL APPOSITION. NOTE: SLOWLY ADVANCING THE LVIS DEVICE WHILE ADJUSTING THE MICROCATHETER POSITION WILL ENSURE ACCURATE DEPLOYMENT. MAINTAIN SIMULTANEOUS CONTROL OF THE LVIS DEVICE AND MICROCATHETER IN ORDER TO POSITION AND EXPAND THE DEVICE AT THE PROPER LOCATION. CAUTION: USING A RAPID MICROCATHETER WITHDRAWAL TECHNIQUE TO DEPLOY THE LVIS DEVICE IS NOT RECOMMENDED AND MAY RESULT IN DEVICE ELONGATION. 19. IF LVIS DEVICE POSITIONING IS NOT SATISFACTORY, THE LVIS DEVICE MAY BE RECAPTURED AND REPOSITIONED IF IT IS NOT FULLY DEPLOYED. THE LVIS DEVICE MAY BE RECAPTURED UNTIL THE POINT WHERE THE PROXIMAL END OF THE LVIS DEVICE MARKERS IS ALIGNED 3 MM PROXIMALLY WITH THE MICROCATHETER DISTAL MARKER BAND (APPROXIMATELY 75% DEPLOYED). CAUTION: IF RESISTANCE IS FELT WHILE RECAPTURING THE LVIS DEVICE, DO NOT CONTINUE TO RECAPTURE THE DEVICE. WITHDRAW THE MICROCATHETER SLIGHTLY TO UNSHEATH THE LVIS DEVICE (WITHOUT EXCEEDING THE RECAPTURE LIMIT), AND THEN ATTEMPT TO RECAPTURE THE LVIS DEVICE. CAUTION: THE LVIS DEVICE MUST NOT BE RE-DEPLOYED MORE THAN THREE TIMES. NOTE: THE LVIS DEVICE DELIVERY WIRE SHOULD NOT BE UTILIZED AS A GUIDEWIRE. DO NOT TORQUE THE LVIS DEVICE. A TORQUE DEVICE SHOULD NOT BE USED. 20. IF LVIS DEVICE POSITIONING IS SATISFACTORY, CAREFULLY RETRACT THE MICROCATHETER AND ADVANCE THE DELIVERY WIRE TOGETHER, TO ALLOW THE LVIS DEVICE TO DEPLOY ACROSS THE NECK OF THE ANEURYSM. ENSURE THE DEVICE PROXIMAL RADIOPAQUE END MARKERS ARE SUFFICIENTLY PROXIMAL TO THE ANEURYSM NECK TO ENSURE AN ADEQUATE LANDING ZONE. THE LVIS DEVICE WILL EXPAND AND TOTAL LENGTH MAY FORESHORTEN UP TO 60% FROM ITS UNDEPLOYED LENGTH (REFER TO TABLE 1A/B/C) AS IT EXITS THE MICROCATHETER. ENSURE MICROCATHETER IS RETRACTED AND CLEAR FROM THE PROXIMAL FLARED ENDS. NOTE: VISUALIZE AND REFER TO THE IMPLANT RADIOPAQUE END MARKERS TO MAINTAIN ADEQUATE IMPLANT LENGTH ON EACH SIDE OF THE ANEURYSM NECK OR TARGET LOCATION TO ENSURE APPROPRIATE NECK COVERAGE. WARNING: DO NOT DETACH THE LVIS DEVICE IF IT IS NOT PROPERLY POSITIONED IN THE PARENT VESSEL. OBSERVE THE DELIVERY WIRE DISTAL TIP TO ASSURE IT REMAINS WITHIN THE DESIRED LOCATION OF THE PARENT VESSEL. 21. PRIOR TO REMOVING THE DELIVERY WIRE AND IF NECESSARY, CAREFULLY POSITION THE MICROCATHETER DISTAL TO THE LVIS DEVICE TO MAINTAIN ACCESS THROUGH THE LVIS DEVICE. REMOVE AND DISCARD THE DELIVERY WIRE. WARNING: THE LVIS DEVICE DELIVERY WIRE SHOULD NOT BE UTILIZED AS A GUIDEWIRE. DO NOT TORQUE THE LVIS DEVICE. A TORQUE DEVICE SHOULD NOT BE USED. 23. USE THE GUIDEWIRE AND MICROCATHETER TO ACCESS THE ANEURYSM THROUGH THE LVIS DEVICE CELLS. WARNING: OBSERVE LVIS DEVICE MARKER POSITION DURING PLACEMENT OF THE MICROCATHETER INTO THE ANEURYSM TO ENSURE THAT THE LVIS DEVICE DOES NOT MIGRATE OR DISLODGE FROM ITS DEPLOYED POSITION. 24. AFTER THE MICROCATHETER IS POSITIONED WITHIN THE ANEURYSM, DETACHABLE COILS MAY BE DELIVERED INTO THE ANEURYSM ACCORDING TO CONVENTIONAL METHODS. WARNING: OBSERVE LVIS DEVICE MARKER POSITION DURING THE COILING PROCEDURE TO ENSURE THAT THE DEVICE DOES NOT MIGRATE FROM ITS DEPLOYED POSITION. 25. AFTER PLACING THE LAST COIL, VERIFY THAT THE LVIS DEVICE HAS REMAINED PATENT AND PROPERLY POSITIONED. ADVANCE A GUIDEWIRE TO THE MICROCATHETER TIP AND CAREFULLY REMOVE THE MICROCATHETER THROUGH THE LVIS DEVICE CELLS. NOTE: A MICROCATHETER MAY BE POSITIONED INTO THE ANEURYSM SAC PRIOR TO DELIVERY OF THE LVIS DEVICE. THE MICROCATHETER WILL BE SUPPORTED BY THE LVIS DEVICE DURING DELIVERY OF EMBOLIC COILING. AFTER COMPLETING THE COILING, THE MICROCATHETER SHOULD BE CAREFULLY REMOVED TO AVOID DISLODGING THE LVIS DEVICE. 27. CAUTION: CAREFULLY WATCH THE LVIS DEVICE DISTAL AND PROXIMAL MARKERS WHEN PASSING THROUGH THE DEPLOYED LVIS DEVICE WITH EMBOLIC COILING MICROCATHETERS TO AVOID DISPLACING THE LVIS DEVICE. INVESTIGATION CONCLUSION: THE PHYSICAL DEVICE WAS NOT AVAILABLE FOR EVALUATION TO INVESTIGATE IF A CONDITION EXISTED THAT WOULD HAVE CONTRIBUTED TO THE REPORTED EVENT. SUPPLEMENTAL IMAGING WAS ALSO UNAVAILABLE FOR REVIEW; WITHOUT IMAGING, THE INVESTIGATION CANNOT VERIFY THE EVENT OCCURRED AS DESCRIBED, NOR COULD THE INVESTIGATION FURTHER EXAMINE THE CAUSE OF THE REPORTED EVENT. THIS INFORMATION MAY BE UPDATED IF ADDITIONAL INFORMATION IS PROVIDED AT A LATER DATE. MICROVENTION IS SUBMITTING THIS REPORT TO COMPLY WITH FDA REPORTING REGULATIONS UNDER 21 CFR PARTS 4 AND 803. THIS REPORT IS BASED UPON INFORMATION OBTAINED BY MICROVENTION, WHICH THE COMPANY MAY NOT HAVE BEEN ABLE TO FULLY INVESTIGATE OR VERIFY PRIOR TO THE DATE THE REPORT WAS REQUIRED BY THE FDA. MICROVENTION HAS MADE REASONABLE EFFORTS TO OBTAIN MORE COMPLETE INFORMATION AND HAS PROVIDED AS MUCH RELEVANT INFORMATION AS IS AVAILABLE TO THE COMPANY AS OF THE SUBMISSION DATE OF THIS REPORT. THIS REPORT DOES NOT CONSTITUTE AN ADMISSION OR A CONCLUSION BY FDA, MICROVENTION, OR ITS EMPLOYEES THAT THE DEVICE, MICROVENTION, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE EVENT DESCRIBED IN THE REPORT. THIS STATEMENT SHOULD BE INCLUDED WITH ANY INFORMATION OR REPORT DISCLOSED TO THE PUBLIC UNDER THE FREEDOM OF INFORMATION ACT. ANY REQUIRED FIELDS THAT ARE UNPOPULATED ARE BLANK BECAUSE THE INFORMATION IS CURRENTLY UNKNOWN OR UNAVAILABLE. A GOOD FAITH EFFORT WILL BE MADE TO OBTAIN THE APPLICABLE INFORMATION RELEVANT TO THE REPORT. IF INFORMATION IS PROVIDED IN THE FUTURE, A SUPPLEMENTAL REPORT WILL BE ISSUED.