SHARK/S-LINE
Received Jul 2, 2026 · Event occurred Jun 3, 2026
Report 9611102-2026-00036 · MDR key 25690293
Device
Generic name
Cutting Electrode Bipo 24fr 12/30°
Manufacturer
Richard Wolf GmbhModel number
46221313Catalog number
4622.1313
Lot number
21006297
Product problems
- Material Deformation
Patient
NA · Unknown
- Rupture
Narrative
Description of Event or Problem
ACCORDING TO THE REPORT, A CONCEALED BLADDER RUPTURE OCCURRED DURING TRANSURETHRAL RESECTION OF THE PROSTATE (TURP). BLADDER RECONSTRUCTION WAS SUBSEQUENTLY PERFORMED USING A ROBOT. THE REMAINDER OF THE OPERATION PROCEEDED WITHOUT COMPLICATIONS. THE PROCEDURE WAS COMPLETED. HOWEVER, THERE WAS A DELAY, AND THE SPECIALIST HAD TO PERFORM ADDITIONAL TREATMENT.
Additional Manufacturer Narrative
THE BIPO 24FR 12/30° CUTTING ELECTRODE, TYPE 46221313, WAS MANUFACTURED ON NOVEMBER 25, 2025, WITH LOT NUMBER 21006297, AND BOOKED INTO STOCK. THE LOT SIZE WAS 166 PACKAGES; NO SPECIAL APPROVALS WERE ISSUED. AN EVALUATION OF THE COMPLAINT DATABASE REVEALED NO FURTHER COMPLAINTS REGARDING THIS LOT. THE RETURNED BIPOLAR RESECTION ELECTRODE (REF 4622131) SHOWED SIGNIFICANT MECHANICAL DEFORMATION AT THE DISTAL WORKING END. THE INSULATION WAS INTACT, WITH NO SIGNS OF THERMAL DAMAGE OR DISCOLORATION. A SLIGHT PROXIMAL SHIFT IN THE INSULATION OF APPROXIMATELY 1.8 MM WAS OBSERVED. THE DIELECTRIC STRENGTH TEST AT 3 KV SHOWED NO INSULATION BREAKDOWN. THE RF GENERATOR USED (ERBE VIO 3) AND THE SPECIFIED SETTINGS (HIGH CUT BIPOLAR 4, SOFT COAG BIPOLAR 5) ARE CONSISTENT WITH THE INTENDED USE OF THE PRODUCT. NO INFORMATION WAS AVAILABLE REGARDING OTHER DEVICES USED DURING THE PROCEDURE. IT COULD NOT BE CONCLUSIVELY DETERMINED WHETHER THE OBSERVED MECHANICAL DEFORMATION AND DISPLACEMENT OF THE INSULATION OCCURRED DURING CLINICAL USE OR DURING THE REMOVAL OR HANDLING OF THE PRODUCT AFTER THE PROCEDURE. THE INVESTIGATION FOUND NO EVIDENCE THAT THE OBSERVED FINDINGS CONTRIBUTED TO THE REPORTED INCIDENT. IN PARTICULAR, NO SIGNS OF ELECTRICAL INSULATION FAILURE OR DEVICE MALFUNCTION WITHIN ITS SPECIFIED PERFORMANCE PARAMETERS WERE DETECTED. BASED ON THE AVAILABLE INFORMATION AND INVESTIGATION RESULTS, NO DEVICE-RELATED ROOT CAUSE COULD BE IDENTIFIED. THE REPORTED EVENT IS CONSISTENT WITH A KNOWN PROCEDURAL RISK ASSOCIATED WITH GAS ACCUMULATION DURING A TURP, AS DESCRIBED IN THE LITERATURE AND ADDRESSED IN THE INSTRUCTIONS FOR USE. A CLEAR CAUSE-AND-EFFECT RELATIONSHIP CANNOT BE ESTABLISHED. APPLICATION-RELATED FACTORS ARE CONSIDERED THE MOST LIKELY CONTRIBUTING FACTORS. THE CURRENT INSTRUCTIONS FOR USE (GA-D342) EXPLICITLY POINT OUT THIS RISK ("RISK OF EXPLOSION WHEN ACTIVATING THE ELECTRODE IN AIR OR GAS BUBBLES, E.G., IN THE AREA OF THE BLADDER DOME") AND INCLUDE APPROPRIATE MEASURES TO MINIMIZE THE RISK: - ACTIVATE THE ELECTRODE EXCLUSIVELY IN IRRIGATION FLUID - ACTIVATE ONLY UNDER DIRECT VISUAL OBSERVATION AND IN CONTACT WITH TISSUE THESE RISKS ARE DESCRIBED IN RISK ASSESSMENT B2-3, AND THE INSTRUCTIONS FOR USE INCLUDE REFERENCES TO THEM AND WARNINGS ABOUT THEM. A RECENT ANALYSIS OF PRODUCT SURVEILLANCE DATA SHOWS NO INDICATIONS OF A CLUSTER OF SIMILAR INCIDENTS INVOLVING THIS PRODUCT.