inforMED
InjuryNKB

EXPEDIUM

Received Jun 22, 2026

Report 1526439-2026-00846 · MDR key 25587067

Device

Generic name

Orthosis, Spinal Pedicle Fixation, For Degenerative Disc Disease

Catalog number

179702000

Product problems

  • Adverse Event Without Identified Device or Use Problem

Patient

42 YR · Unknown

  • Fatigue
  • Bone Fracture(s)
  • Inflammation
  • Pain
  • Loss of Range of Motion
  • Depression
  • Impaired Healing
  • Numbness
  • Thrombosis/Thrombus
  • Unspecified Tissue Injury

Narrative

Additional Manufacturer Narrative

PRODUCT COMPLAINT # (B)(4). THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803 (AND/OR PART 4, AS APPLICABLE). THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY DEPUY SYNTHES, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, DEPUY SYNTHES, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. ADDITIONAL NARRATIVE: D4: UDI: AS THE LOT NUMBER FOR THE DEVICE INVOLVED IN THE EVENT WAS NOT PROVIDED, THE FULL UDI IS CURRENTLY NOT AVAILABLE. E3 INITIAL REPORTER OCCUPATION: LAWYER. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem

ON JULY 13, 2020 IT WAS NOTED THAT SINCE SURGERY AND EXTUBATION, HER MENTAL STATUS HAS BEEN ALTERED. INITIALLY 7/7-8 SHE WAS MORE LETHARGIC BUT BY DOCUMENTATION SEEMED TO HAVE A FLUCTUATING LEVEL OF AROUSAL/ALERTNESS AND SOME DISORIENTATION. STARTING (B)(6) AND INTO (B)(6), SHE HAS HAD PROGRESSIVE WORSENING OF AGITATION, SLEEP DISTURBANCE, AND DISORIENTATION, AS WELL AS NEW HALLUCINATIONS, ILLUSIONS AND DELUSIONS. DURING THIS PERIOD THE PATIENT'S MENTAL STATUS WAS WAXING AND WANING. ON (B)(6) 2020 THE PATIENT WAS RELEASED FROM THE HOSPITAL. ON (B)(6) 2020, X-RAYS WERE TAKEN WHICH SHOWED MULTIPLE THORACIC BURST/COMPRESSION FRACTURES, MOST SEVERE AT T6. ON (B)(6) 2020 THE SURGEON NOTED THAT: SHE DID FAIRLY WELL EARLY ON REGAINING SOME OF HER NEUROLOGIC FUNCTION SHE HAD LOST THROUGH PHYSICAL THERAPY BUT THEN HAD COLLAPSE THROUGH HER MIDTHORACIC SPINE. ON (B)(6) 2020 THE SURGEON NOTED THAT: WE INITIALLY INTERVENED TO STOP THE COLLAPSE OF HER THORACIC FRACTURES BY FUSING HER FROM T3-T9. SHE DID WELL INITIALLY AND THEN QUICKLY HER SOFT TISSUES HAD HER CERVICOTHORACIC JUNCTION FAILED. THIS LEFT US NO CHOICE BUT TO INTERVENE BY FUSING BETWEEN THE 2 PRIOR INTERVENTIONS AND EXTENDING DOWN INTO HER LUMBAR SPINE. ON (B)(6) 2020 IT WAS NOTED THAT THE PATIENT HAS TROUBLE STANDING UP. ON (B)(6), 2020 THE PATIENT UNDERWENT A CT SCAN OF HER THORACIC SPINE. THE IMAGING REPORT SHOWED A FRACTURE OF THE MEDIAL ROD OF THE T6 LEVEL. THE IMPRESSION GIVEN WAS A COMMINUTED EMOTIONAL INJURIES DEFORMITY OF T6 WITH ASSOCIATED FOCAL KYPHOSIS. AT THE END OF (B)(6) 2020 THE PATIENT DEVELOPED BOILS OVER HER OCCIPUT AND NECK THAT WERE LARGE AND REQUIRED DRAINAGE BY HER DERMATOLOGIST. THE APPEARANCE OF THESE WERE UNUSUAL AND THERE WAS SUSPICION THAT THERE WAS POTENTIALLY SOME FOREIGN OBJECT (LIKE GLASS FROM THE ACCIDENT) CAUSING THEM BECAUSE OF HOW STRANGE THEY LOOKED. ON (B)(6) 2020 PATIENT WAS TREATED AT (B)(6) CLINIC. IT WAS NOTED THAT: SHE MOST RECENTLY WAS OPERATED ON IN (B)(6) 2020 WITH INSTRUMENTATION FROM C4 TO L4. ON (B)(6) 2020 THE PATIENT UNDERWENT AN MRI OF HER CERVICAL, THORACIC AND LUMBAR SPINE. THE FINDINGS STATED THAT: ON THIS MRI, THE EXTENSIVE SPINAL INSTRUMENTATION RESULTS AND SIGNAL LOSS AT MULTIPLE LEVELS. ON THE CT, THERE IS A BURST TYPE FRACTURE AND LAMINECTOMY AT T6 WITH MILD RETROPULSION. ADDITIONAL FRACTURES WERE OBSERVED ON THE CT SCAN. THE MRI FINDINGS ALSO STATED: IN THE LAMINECTOMY BED AT T6, DEEP TO THE INSTRUMENTATION, THERE IS A FLUID CONNECTION MEASURING UP TO 2.4CM WITH SURROUNDING MILD CONTRAST ENHANCEMENT WHICH EXTENDS TO THE SKIN. GIVEN THE CLINICAL PRESENTATION, THIS IS CONCERNING FOR INFECTION. ON (B)(6) 2021 THE PATIENT WAS DIAGNOSED WITH A LARGE WOUND POSTERIOR SCALP AFTER PROLONGED HOSPITALIZATION. PHYSICAL EXAMINATION SHOWED A 2CM SCAR-LIKE PATCH OF ALOPECIA, SLIGHTLY ERYTHEMATOUS, IN THE SAME LOCATION AS THE PRIOR LARGE CRUSTED NODULE OVERLYING THE OCCIPITAL PROTUBERANCE. ON (B)(6) 2021 CT SCAN SHOWED ANOTHER FRACTURE OF THE MEDIAL FUSION ROD AT THE T6 LEVEL. THE IMAGING REPORT ALSO IDENTIFIED COMPRESSION DEFORMITIES OF THE T3-T5 VERTEBRAL BODIES RESULTING MILD KYPHOSIS. ALSO, THE IMAGING REPORTED INDICATED AN UNUNITED RIGHT ANTERIOR C1 ARCH FRACTURE AND MULTILEVEL THORACIC COMPRESSION FRACTURES. ON (B)(6) 2021 THE PATIENT WAS COMPLETED PHYSICAL THERAPY AND WAS DISCHARGED FROM SSM PHYSICAL THERAPY AFTER ACHIEVING ALL OF HER GOALS. HER PROGNOSIS AT THE TIME OF DISCHARGE WAS GOOD AND IT WAS SPECIFICALLY NOTED THAT HAS MADE GREAT IMPROVEMENT UP TO THIS POINT. ON (B)(6) 2021 THE PATIENT UNDERWENT PLACEMENT OF AN INFERIOR VENA CENA FILTER DUE TO A POSSIBLE INFECTION OF SURGICAL HARDWARE. ON (B)(6) 2021 THE SURGEON AND SURGICAL TEAM PERFORMED SEVERAL PROCEDURES INCLUDING AN ANTERIOR LUMBAR INTERBODY FUSION AND BONE GRAFT. ALL PROCEDURES WERE PERFORMED PURSUANT TO THE STANDARD OF CARE, WITH NO DEVIATION FROM THE SURGICAL STEPS. THESE PROCEDURES INCLUDED THE IMPLANTATION OF THE DEPUY DEFENDANT'S PRODUCTS.