SUR-FIT NATURA
Received Jun 4, 2026
Report 9618003-2026-01057 · MDR key 25390218
Device
Generic name
Protector, Ostomy
Manufacturer
Convatec Dominican Republic IncModel number
421034Lot number
5H04967
Product problems
- Malposition of Device
Patient
NA · Unknown
- Hemorrhage/Blood Loss/Bleeding
- Tissue Breakdown
- Skin Inflammation/ Irritation
Narrative
Additional Manufacturer Narrative
DEVICE 8 OF 20. (B)(6). BASED ON THE AVAILABLE INFORMATION, THIS EVENT IS DEEMED TO BE A REPORTABLE MALFUNCTION. PHOTOGRAPH, VIDEO AND/OR PHYSICAL SAMPLE EVALUATION: NO PHOTOGRAPH ASSOCIATED WITH THIS CASE WAS RECEIVED. NO RETURN SAMPLE HAS BEEN RECEIVED FOR THIS COMPLAINT. BATCH RECORD REVISION RESULTS: PACKAGING PROCESS PERFORMED IN THE FLOW WRAP LINE: LOT 5H04967 WAS MANUFACTURED ON 29/AUG/2025, IN FLOW WRAP LINE, WITH A TOTAL OF (B)(4). THE COMPLAINT ENGINEER I PERFORMED A BATCH RECORD REVIEW ON 29/MAY/2026, TO VERIFY IF ALL THE APPLICABLE PROCEDURES WERE FOLLOWED AND NO ISSUES WERE FOUND; ALL THE COMPONENTS FOR ASSEMBLY WERE CORRECT PER BOM AND ALL THE TOOLING INFORMATION DOCUMENTED WAS ALSO CORRECT, SAP MATERIAL ID 1738016 AND MANUFACTURING ORDER (B)(4). THE DEFECT REPORTED BY THE CUSTOMER COULD OCCUR DURING THE SUB-ASSEMBLY PROCESS PERFORMED IN THE FLOW WRAP LINE. FOR THIS REASON, A DETAILED BATCH RECORDS REVIEW WERE PERFORMED OF THE SUBASSEMBLY LOT MANUFACTURED IN THIS LINE. ASSEMBLY PROCESS PERFORMED IN THE ACCORDION LINE: THE SUBASSEMBLY LOT: 5J00840, ORDER (B)(4), MATERIAL 1714356, WAS MANUFACTURED ON 09/04/2025 IN THE ACCORDION ASSEMBLY LINE MANUFACTURING LINE, WITH A TOTAL OF (B)(4). THE COMPLAINT ENGINEER I PERFORMED A BATCH RECORD REVIEW ON 05/29/2026, AND IT WAS CONFIRMED THAT THE APPLICABLE PROCEDURES WERE FOLLOWED, THE MATERIALS WERE CORRECT AS PER BOM, AND THE EQUIPMENT SETTINGS WERE ACCORDING TO THE PROCESS INSTRUCTION. TRILAMINATION PROCESS PERFORMED IN THE DELTA CRUSADER LINE: THE SUBASSEMBLY LOT: 5J00545, ORDER (B)(4), MATERIAL 1714350, WAS MANUFACTURED ON 09/07/2025 IN THE DELTA CRUSADER NEW MANUFACTURING LINE, WITH A TOTAL OF (B)(4). THE COMPLAINT ENGINEER I PERFORMED A BATCH RECORD REVIEW ON 05/29/2026, AND IT WAS CONFIRMED THAT THE APPLICABLE PROCEDURES WERE FOLLOWED, THE MATERIALS WERE CORRECT AS PER BOM, AND THE EQUIPMENT SETTINGS WERE ACCORDING TO THE PROCESS INSTRUCTION. HISTORICAL COMPLAINTS REVIEW: ON 29/MAR/2026, COMPLAINTS ENGINEER I RAN A QUERY IN DATABASE IN ORDER TO VERIFY THE COMPLAINTS REPORTED FOR THE LOT 5D01797 CORRESPONDING TO THE MALFUNCTION "SKIN BARRIER STARTER HOLE IS DEFECTIVE (E.G MISALIGNMENT OR OFF CENTER), LEAKAGE MAY OCCUR (MOLDABLE ONLY)" DEFECT AND AS RESULT ONE (1) ADDITIONAL COMPLAINT WAS IDENTIFIED DURING THIS SEARCH AS PER WORK INSTRUCTIONS (WI). HISTORICAL NONCONFORMANCE REVIEW: ON 29/MAR/2026, COMPLAINTS ENGINEER I RAN A QUERY IN DATABASE LOOKING FOR ANY IN PROCESS NONCONFORMANCE / CORRECTIVE AND PREVENTIVE ACTIONS (CAPA) (S) ASSOCIATED TO THE MALFUNCTION "SKIN BARRIER STARTER HOLE IS DEFECTIVE (E.G MISALIGNMENT OR OFF CENTER), LEAKAGE MAY OCCUR (MOLDABLE ONLY)" DEFECT FOR THE LOT NUMBERS 5D01797, 5J00840, 5J00545 AND AS RESULT, NO NONCONFORMANCE / CAPA (S) FOR THIS MALFUNCTION WERE GENERATED DURING THE MANUFACTURING PROCESS OF THE REFERENCED LOTS. CURRENT QUALITY CONTROLS: BASED ON THE PROCESS INSTRUCTION (PI), THE FOLLOWING TESTS ARE PERFORMED IN THE MANUFACTURING LINES, IN ORDER TO IDENTIFY THIS FAILURE MODE IN OUR MANUFACTURING PROCESS: TEST METHODS (TM) "VISUAL NONCONFORMITIES - METHOD 2". FREQUENCY: HOURLY. SAMPLE QUANTITY: 2 SAMPLES. ACCEPTANCE CRITERIA: ACCEPT = 0 / REJECT = 1. DIMENSIONAL INSPECTION: METHOD: CALIBRATED RULER OR CALIPER. FREQUENCY: HOURLY. SAMPLE QUANTITY: 2 SAMPLES. ACCEPTANCE CRITERIA: MUST MEET SPECIFICATION. IN PROCESS VISUAL INSPECTION (OPERATOR): FREQUENCY: CONTINUOUS INSPECTION IN PROCESS. SAMPLE QUANTITY: N/A (10 PERCENT VISUAL). DEFECT RATE ANALYSIS: THERE HAVE BEEN 20 DEFECTIVE PART CONFIRMED TO DATE FROM A LOT SIZE OF (B)(4). THIS REPRESENTS A DEFECT RATE OF (B)(4) WHICH IS WELL WITHIN AN APPROPRIATE AQL FOR THIS DEFECT WHICH SHOULD BE (B)(4) BASED ON OUR STANDARD OPERATING PROCEDURES. IN ADDITION, ALL THE IN-PROCESS TESTING ON THIS LOT DID NOT FIND A SINGLE DEFECTIVE UNIT, WHICH CONFIRMS THAT THE LOT IS UNLIKELY TO BREACH AN AQL OF (B)(4). IMPORTANTLY TO DATE, IT IS WELL WITHIN OUR ACCEPTED AQL LEVEL FOR THIS TYPE OF FAILURE MODE OR DEFECT. CONCLUSIONS: A REVIEW OF BATCH RECORDS WAS COMPLETED AND SHOWED THAT ALL RELEVANT TESTS REQUIRED DURING THE MANUFACTURING PROCESS AND FINAL PRODUCT RELEASE HAD BEEN FULFILLED AND MET THE REQUIREMENTS. NO DISCREPANCIES RELATED TO THIS ISSUE WERE FOUND WITHIN THE DOCUMENTATION. THIS ISSUE WILL BE MONITORED THROUGH THE POST MARKET PRODUCT MONITORING REVIEW PROCESS, STANDARD OPERATING PROCEDURE (SOP). TO DATE NO ADDITIONAL INFORMATION HAS BEEN RECEIVED. SHOULD ADDITIONAL INFORMATION BECOME AVAILABLE, A FOLLOW-UP REPORT WILL BE SUBMITTED. FDA REGISTRATION NUMBER: REPORTING SITE: 1049092. MANUFACTURING SITE: 9618003.
Description of Event or Problem
THE END USER CALLED TO REPORT THAT THE LAST TWO BOXES SHE HAD RECEIVED CONTAINED PRODUCTS WITH OFF-CENTERED STARTER HOLES. SHE EXPLAINED THAT THIS ISSUE HAD LED TO PREMATURE LEAKAGE, REQUIRING HER TO CHANGE THE PRODUCT ONCE TO TWICE DAILY INSTEAD OF HER USUAL WEAR TIME OF THREE TO FOUR DAYS. DUE TO THESE MORE FREQUENT CHANGES, SHE REPORTED EXPERIENCING SKIN IRRITATION AND BLEEDING. SHE STATED THAT SHE WOULD CONTINUE TO MONITOR HER SKIN CONDITION, AND IT WAS DISCUSSED THAT SHE SHOULD CONSIDER CONTACTING AN NURSE SPECIALIZED IN WOUND, OSTOMY, AND CONTINENCE (NSWOC) IF HER SKIN DID NOT IMPROVE. NO PHOTOGRAPH WAS AVAILABLE AT THIS TIME.