TISSUE SPARING FEM CORE CASE 2

Received Apr 6, 2026 · Event occurred Feb 11, 2026

Report 1818910-2026-06015 · MDR key 24790773

Device

Generic name

Hip Instruments : Instrument Cases

Catalog number

259807420

Lot number

C1DAB4

Product problems

  • No Apparent Adverse Event

Patient

NA · Unknown

  • No Clinical Signs, Symptoms or Conditions

Narrative

Description of Event or Problem

IT WAS REPORTED THAT THE DEVICE TISSUE SPARING FEM CORE CASE 2 REPORTED WITHOUT ANY ALLEGATIONS. IT DID NOT HAPPEN IN SURGERY. DURING MANUFACTURER'S INVESTIGATION OF THE RETURNED DEVICE IT WAS IDENTIFIED THAT THE BLACK NYLON COATING OF RACK SECTION PEELING OFF, THREE BRACKET WERE DAMAGED, 2 WERE FOUND BENT AND THE OTHER ONE WAS CHIPPED. ADDITIONALLY, TO THE CONSISTENT DAMAGE EXHIBITED ON DEVICE, CORROSION PATTERNS WERE FOUND BOTH INSIDE AND OUTSIDE OF THE CUTTING SURFACE.

Additional Manufacturer Narrative

PRODUCT COMPLAINT # (B)(4). THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803 (AND/OR PART 4, AS APPLICABLE). THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY DEPUY SYNTHES, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, DEPUY SYNTHES, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. ADDITIONAL NARRATIVE: H3, H6: PRODUCT INVESTIGATION SUMMARY: THE PRODUCT WAS RETURNED TO DEPUY SYNTHES FOR EVALUATION. VISUAL ANALYSIS OF THE TISSUE SPARING FEM CORE CASE 2 REVEALED THE BLACK NYLON COATING OF RACK SECTION PEELING OFF, THREE BRACKET WERE DAMAGED, 2 WERE FOUND BENT AND THE OTHER ONE WAS CHIPPED. ADDITIONALLY, TO THE CONSISTENT DAMAGE EXHIBITED ON DEVICE, CORROSION PATTERNS WERE FOUND BOTH INSIDE AND OUTSIDE OF THE CUTTING SURFACE. THE OBSERVED CONDITIONS WERE IDENTIFIED AS AN END-OF-LIFE INDICATOR, DAMAGE CONSISTENT WITH REPEATED USE AND SERVICING. THE LIFECYCLE REQUIREMENTS OF THE DEVICE ARE EVENT RELATED AND DEPEND ON THE USE AND INSPECTION OF THE DEVICE IN CLINICAL PRACTICE. AS THE DEVICE CAN BE DAMAGED ON THE FIRST OR 100TH USE, THE DEVICE MUST BE PROPERLY INSPECTED PRIOR TO EACH SURGICAL USE. REFER TO THE DEVICE/COUNTRY SPECIFIC IFU FOR INFORMATION RELATED TO END OF LIFE, REPROCESSING INSTRUCTIONS, AND INSPECTION PROCEDURES. WHERE CORROSION/OXIDATION IS IDENTIFIED AROUND THE SURFACE OF THE DEVICE, ALONGSIDE DAMAGE CONSISTENT WITH NORMAL WEAR, THIS SUGGESTS THAT THE PASSIVE LAYER OF THE METAL HAS BEEN WORN DOWN FROM REPEATED USE (DUE TO NORMAL USE DAMAGE) ALLOWING FOR THE METALLIC SURFACE UNDERNEATH TO BECOME SUSCEPTIBLE TO CORROSION/OXIDATION. A DIMENSIONAL INSPECTION AND FUNCTIONAL TESTING WERE NOT PERFORMED AS IT IS NOT APPLICABLE TO THE COMPLAINT CONDITION. THE OVERALL COMPLAINT WAS CONFIRMED AS THE OBSERVED CONDITION OF THE TISSUE SPARING FEM CORE CASE 2 WOULD HAVE CONTRIBUTED TO A DEVICE ISSUE. BASED ON THE INVESTIGATION FINDINGS, IT HAS BEEN DETERMINED THAT NO CORRECTIVE AND/OR PREVENTATIVE ACTION IS PROPOSED. THERE IS NO INDICATION THAT A DESIGN OR MANUFACTURING ISSUE HAS CAUSED THE REPORTED COMPLAINT CONDITION. AS PART OF DEPUY SYNTHES QUALITY PROCESS, ALL DEVICES ARE MANUFACTURED, INSPECTED, AND RELEASED TO APPROVED SPECIFICATIONS. ADDITIONAL MONITORING FOR ANY POTENTIAL SAFETY SIGNALS WILL BE CONDUCTED THROUGH COMPLAINT TRENDING AND OTHER POST-MARKET SAFETY SURVEILLANCE ACTIVITIES. DEVICE HISTORY LOT ==> THE PRODUCT INVESTIGATION FOUND NO EVIDENCE SUSPECTING AN ERROR IN THE MANUFACTURING OR MATERIAL THAT WOULD BE A CONTRIBUTING FACTOR IN THE REPORTED ALLEGATION(S). A MANUFACTURING RECORDS EVALUATION (MRE) WAS NOT PERFORMED. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.