inforMED
MalfunctionGAQ

STLESS STEEL SIL 4X18IN 6 S/A V-40

Received Jan 15, 2026

Report 2210968-2026-00590 · MDR key 24086650

Device

Generic name

Suture, Nonabsorbable, Steel

Manufacturer

Ethicon Inc.

Catalog number

M649G

Lot number

107QPE

Product problems

  • Material Separation

Patient

NA · Unknown

  • No Clinical Signs, Symptoms or Conditions

Narrative

Description of Event or Problem

IT WAS REPORTED THAT A PATIENT UNDERWENT AN UNKNOWN CARDIOVASCULAR SURGERY ON AN UNKNOWN DATE AND SUTURE WAS USED. IT WAS FOUND THAT THE WIRE WAS DETACHED. NO TROUBLES WERE CAUSED TO THE PATIENT AND THE DOCTOR BECAUSE OF THIS ISSUE. IT WAS NOT A CONTROL RELEASE NEEDLE. ADDITIONAL SUTURE WAS PERFORMED TO COMPLETE THE CASE. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT. FURTHER DETAILS ARE NOT PROVIDED FROM THE HP.

Additional Manufacturer Narrative

PRODUCT COMPLAINT # (B)(4) THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON INC, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON INC, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. THE FOLLOWING INFORMATION WAS REQUESTED, BUT UNAVAILABLE: WHEN WAS THE NEEDLE DETACHED/PULLED OFF FROM THE SUTURE (IN THE PACKAGE, DURING REMOVAL FROM PACKAGE, DURING HANDLING PRIOR TO USE ON PATIENT OR DURING USE ON THE PATIENT)? PLEASE SPECIFY UNK. DID THE NEEDLE FALL INTO THE PATIENT? IF YES, WAS THE NEEDLE PIECE REMOVED FROM THE PATIENT DURING THE SAME PROCEDURE? UNK ATTEMPTS ARE BEING MADE TO RETRIEVE THE DEVICE. TO DATE THE DEVICE HAS NOT BEEN RETURNED. IF THE DEVICE OR FURTHER DETAILS ARE RECEIVED AT A LATER DATE A SUPPLEMENTAL MEDWATCH WILL BE SENT. A MANUFACTURING RECORD EVALUATION WAS PERFORMED FOR THE FINISHED DEVICE LOT NUMBER, AND NO RELATED NON-CONFORMANCES WERE IDENTIFIED.

Additional Manufacturer Narrative

PRODUCT COMPLAINT # (B)(4). THIS REPORT IS BEING SUBMITTED PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH HAS NOT BEEN INVESTIGATED OR VERIFIED PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY ETHICON INC, OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE PRODUCT, ETHICON INC OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL REPORT, A FOLLOW-UP REPORT WILL BE FILED AS APPROPRIATE. ADDITIONAL INFORMATION: H6, D9, H3. H3 INVESTIGATION SUMMARY: THE PRODUCT WAS RETURNED TO ETHICON FOR EVALUATION. ONE DETACHED NEEDLE AND ONE STEEL SUTURE PIECE WERE RECEIVED FOR ANALYSIS. PRODUCT CODE M649G. UPON VISUAL INSPECTION OF THE RETURNED SAMPLE, THE SWAGE AND ATTACHMENT AREA WERE NOTED TO BE AS EXPECTED. THE BARREL HOLE WAS EXAMINED UNDER MAGNIFICATION, AND NO SUTURE REMNANT WAS OBSERVED. THE STEEL SUTURE WAS EXAMINED, AND THE INSERTION MARK WAS OBSERVED TO BE AS EXPECTED. THE FORCE USED TO DETACH THE NEEDLE FROM THE SUTURE COULD NOT BE DETERMINED. GIVEN THE CURRENT CONDITION OF THE RETURNED SAMPLE, IT IS NOT POSSIBLE TO DETERMINE THE POTENTIAL CAUSE OF THE REPORTED EVENT. A MANUFACTURING RECORD EVALUATION WAS PERFORMED FOR THE FINISHED DEVICE BATCH NUMBER, AND NO NON-CONFORMANCES WERE IDENTIFIED. NO CONCLUSION COULD BE REACHED AS TO WHAT CAUSED THE REPORTED COMPLAINT. AS PART OF THE QUALITY PROCESS, ALL DEVICES ARE MANUFACTURED, INSPECTED, AND RELEASED TO APPROVED SPECIFICATIONS.