inforMED

CANE, CRUTCH AND WALKER TIPS AND PADS

Received Dec 16, 2011 · Event occurred Nov 30, 2011

Report 1525712-2011-01079 · MDR key 2379706

Device

Generic name

890.3790

Manufacturer

Unknown

Model number

6291-3F

Product problems

  • Product Quality Problem

Patient

68

  • Laceration(s)

Narrative

Description of Event or Problem

END USER WAS ALLEGEDLY WALKING BEHIND THE WALKER. THOUGHT IT WAS OPENED ALL THE WAY, HOWEVER, NOW DOES NOT BELIEVE THAT IT WAS LOCKED OPEN. THE WALKER FOLDED AND CAUSED THE USER TO ALLEGEDLY FALL. THE PIN THAT HOLDS IT OPEN MAY HAVE POPPED OUT AT SOME POINT EITHER PRIOR OR DURING THE INCIDENT. TWO LARGE SKIN TEARS (ONE 1 1/2 INCHES LONG AND ONE 2 TO 2 1/2 INCHES LONG) AND NOTED ON THE LEFT UPPER ARM BY THE DEALER AND SIGNIFICANT BRUISING ON THE ELBOW AND AROUND SKIN TEARS. END USER ADVISED OF TENDERNESS ON UPPER BICEP. NO MEDICAL TREATMENT WAS SOUGHT.