inforMED
MalfunctionJEQ

ORALBRCHGTOOTHBRUSHHANDLE3756

Received Oct 24, 2025

Report 3000302531-2025-00478 · MDR key 23377419

Device

Generic name

Toothbrush, Powered - Jeq

Model number

3756

Lot number

F40810816

Product problems

  • No Apparent Adverse Event
  • No Apparent Adverse Event

Patient

NA · Unknown

  • No Clinical Signs, Symptoms or Conditions
  • No Clinical Signs, Symptoms or Conditions

Narrative

Description of Event or Problem

TOOTHBRUSH CHARGER BEGAN TO SMOKE BEFORE CATCHING FIRE- ORAL B POWER CARE [DEVICE CATCHING FIRE]. CASE NARRATIVE: CONSUMER EMAIL STATED THAT THE TOOTHBRUSH CHARGER WAS GLOWING. IT THEN BEGAN TO SMOKE BEFORE CATCHING FIRE. NO INJURY WAS REPORTED. 19-DEC-2025 PRODUCT INVESTIGATION RESULT: CONCLUSION CODE OTHER, 'NO MANUFACTURING CAUSE' AND 'NO DESIGN ISSUE' IDENTIFIED BASED ON INVESTIGATION.

Additional Manufacturer Narrative

19-DEC-2025 PRODUCT INVESTIGATION RESULT: COMPLAINED PRODUCT RECEIVED - USER HANDLING WAS IDENTIFIED AS ROOT CAUSE FOR THE COMPLAINT.

Additional Manufacturer Narrative

PRODUCT RETURN WAS REQUESTED OR ITS IN TRANSPORT. EVALUATION WILL OCCUR UPON RECEIPT OF PRODUCT RETURN.

Description of Event or Problem

TOOTHBRUSH CHARGER BEGAN TO SMOKE BEFORE CATCHING FIRE- ORAL B POWER CARE [DEVICE CATCHING FIRE] . CASE NARRATIVE: CONSUMER EMAIL STATED THAT THE TOOTHBRUSH CHARGER WAS GLOWING. IT THEN BEGAN TO SMOKE BEFORE CATCHING FIRE. NO INJURY WAS REPORTED.