ORALBRCHGTOOTHBRUSHHANDLE3772PRO33500
Received Oct 8, 2025
Report 3000302531-2025-00461 · MDR key 23242233
Device
Generic name
Toothbrush, Powered - Jeq
Manufacturer
Braun Gmbh Werk MarktheidenfeldModel number
3772Lot number
3CB42210310
Product problems
- Insufficient Device Problem Information
- Insufficient Device Problem Information
Patient
NA · Female
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
Narrative
Description of Event or Problem
I STABBED MYSELF IN THE FACE [FACE INJURY]. HURTS - FACE [FACIAL PAIN]. TOOTHBRUSH HEAD WON¿T STAY ON. CAME OFF WHEN I WAS DRYING. ORAL B POWER CARE [DEVICE BREAKAGE]. CASE NARRATIVE: CONSUMER E-MAIL STATED THAT HEAD WON'T STAY ON AND NEXT DAY HEAD CAME OFF WHEN SHE WAS DRYING IT. SHE HAS STABBED HERSELF IN THE FACE AND IT HURTS. NO SERIOUS INJURY WAS REPORTED. FOLLOW UP: ON 27-NOV-2025: PRODUCT BATCH LOT NUMBER UPDATED.
Additional Manufacturer Narrative
PRODUCT RETURN WAS REQUESTED OR ITS IN TRANSPORT. EVALUATION WILL OCCUR UPON RECEIPT OF PRODUCT RETURN. PENDING INVESTIGATION.
Description of Event or Problem
STABBED MYSELF IN THE FACE [FACE INJURY], HURTS- FACE [FACIAL PAIN], TOOTHBRUSH HEAD WON¿T STAY ON...CAME OFF WHEN I WAS DRYING- ORAL B POWER CARE [DEVICE BREAKAGE] . CASE NARRATIVE: CONSUMER E-MAIL STATED THAT HEAD WON'T STAY ON AND NEXT DAY HEAD CAME OFF WHEN SHE WAS DRYING IT., SHE HAS STABBED HERSELF IN THE FACE AND IT HURTS. NO SERIOUS INJURY WAS REPORTED.
Additional Manufacturer Narrative
PRODUCT RETURN WAS REQUESTED OR ITS IN TRANSPORT. EVALUATION WILL OCCUR UPON RECEIPT OF PRODUCT RETURN.
Description of Event or Problem
STABBED MYSELF IN THE FACE [FACE INJURY] HURTS- FACE [FACIAL PAIN] TOOTH BRUSH HEAD WON¿T STAY ON...CAME OFF WHEN I WAS DRYING- ORAL B POWER CARE [DEVICE BREAKAGE]. CASE NARRATIVE: CONSUMER E-MAIL STATED THAT HEAD WON'T STAY ON AND NEXT DAY HEAD CAME OFF WHEN SHE WAS DRYING IT. SHE HAS STABBED HERSELF IN THE FACE AND IT HURTS. NO SERIOUS INJURY WAS REPORTED. FOLLOW UP: 27-NOV-2025: PRODUCT BATCH LOT NUMBER UPDATED FOLLOW UP: 11-DEC-2025 PRODUCT INVESTIGATION RESULTS: PRODUCT INVESTIGATION RESULT FOR THE SUSPECT ORAL-B TOOTHBRUSH HANDLE WAS RECEIVED. THE DRIVING SHAFT IS BROKEN AT THE NOTCH. CAUSE OF FAILURE WAS FOUND TO BE CONSUMER RELATED - THE CONTRIBUTION OF INSUFFICIENT MAINTENANCE (STORAGE UNDER WET CONDITION) LEADS TO PITTING CORROSION AT DRIVING SHAFT WHICH IS WEAKENING THE STABILITY OF IT AND AN EFFECT OF FORCE LEADS TO DRIVING SHAFT BROKEN. BASED ON INVESTIGATION RESULTS, "NO MANUFACTURING CAUSE" AND "NO DESIGN ISSUE" WAS IDENTIFIED. NO SERIOUS INJURY WAS REPORTED.
Additional Manufacturer Narrative
11-DEC-2025 PRODUCT INVESTIGATION RESULTS: COMPLAINED PRODUCT RECEIVED - USER HANDLING WAS IDENTIFIED AS ROOT CAUSE FOR THE COMPLAINT.