MalfunctionHNY

ALCON MICROSURGICAL INSTRUMENTS, IRRIGATING CYSTITOME

Received Jan 3, 2025 · Event occurred Oct 1, 2024

Report 2523835-2025-00019 · MDR key 21066331

Device

Generic name

Cystotome

Model number

NA

Catalog number

4251200001

Lot number

16J816

Product problems

  • Complete Blockage
  • Complete Blockage

Patient

NA · Unknown

  • No Clinical Signs, Symptoms or Conditions
  • No Clinical Signs, Symptoms or Conditions

Narrative

Additional Manufacturer Narrative

ADDITIONAL INFORMATION IS PROVIDED IN SECTIONS D.1, D.2, D.4 AND H.11. A SAMPLE WAS NOT RECEIVED AT THE MANUFACTURING SITE FOR EVALUATION FOR THE REPORT OF CANNULA COMPLETELY BLOCKED; THEREFORE, THE CONDITION OF THE PRODUCT COULD NOT BE VERIFIED. A REVIEW OF THE DEVICE HISTORY RECORD TRACEABLE TO THE POSSIBLE LOT NUMBERS, INDICATES THAT THE REPORTED PRODUCT WAS PROCESSED AND RELEASED ACCORDING TO THE REPORTED PRODUCT¿S ACCEPTANCE CRITERIA. BECAUSE A SAMPLE WAS NOT RECEIVED AND THE DEVICE HISTORY RECORD REVIEW OF THE LOT NUMBER PROVIDED INDICATED THE PRODUCT WAS PROCESSED AND RELEASED ACCORDING TO THE PRODUCT¿S ACCEPTABLE CRITERIA, THE ROOT CAUSE FOR CUSTOMER COMPLAINT ISSUE CANNOT BE DETERMINED. THE EXACT ROOT CAUSE FOR THIS COMPLAINT IS UNKNOWN, THEREFORE, SPECIFIC ACTION WITH REGARDS TO THIS COMPLAINT CANNOT BE TAKEN. AN ACCEPTANCE QUALITY LIMIT (AQL) SAMPLING IS PERFORMED TO ENSURE THAT THE PRODUCT MEETS RELEASE ACCEPTANCE CRITERIA. COMPLAINTS ARE REVIEWED AND MONITORED AT REGULAR INTERVALS FOR ANY SIGNIFICANT ADVERSE TRENDS. NO ADVERSE TRENDS HAVE BEEN OBSERVED ASSOCIATED WITH THE REPORTED PRODUCT AND EVENT. NO ADDITIONAL ACTION IS REQUIRED AT THIS TIME. THE MANUFACTURER INTERNAL REFERENCE NUMBER IS: (B)(4). H.10 REFLECTS ALL RELATED REPORT NUMBERS ASSOCIATED WITH THIS PRODUCT EVENT THAT HAVE BEEN SUBMITTED AT THIS TIME.

Additional Manufacturer Narrative

ADDITIONAL INFORMATION IS PROVIDED IN SECTIONS H.6 AND H.11. A SAMPLE WAS NOT RECEIVED AT THE MANUFACTURING SITE FOR EVALUATION FOR THE REPORT OF BLADE WOULD NOT PENETRATE THE CORNEA; THEREFORE, THE CONDITION OF THE PRODUCT COULD NOT BE VERIFIED. A REVIEW OF THE DEVICE HISTORY RECORD TRACEABLE TO THE REPORTED LOT NUMBERS, INDICATES THAT THE REPORTED PRODUCT WAS PROCESSED AND RELEASED ACCORDING TO THE REPORTED PRODUCT¿S ACCEPTANCE CRITERIA. A SAMPLE WAS NOT RECEIVED AT THE MANUFACTURING SITE AND THE DEVICE HISTORY RECORD REVIEW OF THE LOT NUMBER PROVIDED INDICATED THE PRODUCT WAS PROCESSED AND RELEASED ACCORDING TO THE PRODUCT¿S ACCEPTABLE CRITERIA, THEREFORE; THE ROOT CAUSE FOR THE CUSTOMER COMPLAINT ISSUE CANNOT BE DETERMINED. THE EXACT ROOT CAUSE FOR THIS COMPLAINT IS UNKNOWN, THEREFORE, SPECIFIC ACTION WITH REGARDS TO THIS COMPLAINT CANNOT BE TAKEN. ALL KNIVES ARE 100% INSPECTED BY TRAINED OPERATORS USING A MINIMUM OF 10X MAGNIFICATION DURING MANUFACTURING. COMPLAINTS ARE REVIEWED AND MONITORED AT REGULAR INTERVALS FOR ANY SIGNIFICANT ADVERSE TRENDS. THE MANUFACTURER INTERNAL REFERENCE NUMBER IS: (B)(4). H.10 REFLECTS ALL RELATED REPORT NUMBERS ASSOCIATED WITH THIS PRODUCT EVENT THAT HAVE BEEN SUBMITTED AT THIS TIME.

Additional Manufacturer Narrative

INVESTIGATION INCLUDING ROOT CAUSE ANALYSIS IS IN PROGRESS. A SUPPLEMENTAL MDR WILL BE FILED AS NECESSARY IN ACCORDANCE WITH 21 CFR 803.56 WHEN ADDITIONAL REPORTABLE INFORMATION BECOMES AVAILABLE. THE MANUFACTURER INTERNAL REFERENCE NUMBER IS: (B)(4). H10 REFLECTS ALL RELATED REPORT NUMBERS ASSOCIATED WITH THIS PRODUCT EVENT THAT HAVE BEEN SUBMITTED AT THIS TIME.

Description of Event or Problem

A HEALTH CARE PROFESSIONAL REPORTED THAT CANNULA WAS BLOCKED BEFORE THE PHACOEMULSIFICATION SURGERY. THE SURGERY WAS COMPLETED BY REPLACING CANNULA. THERE WAS NO PATIENT INVOLVEMENT. ADDITIONAL INFORMATION RECEIVED AND REPORTED THAT BEFORE CATARACT SURGERY AN OPHTHALMIC CANNULA WAS BLOCKED. THE SURGERY WAS COMPLETED ON THE SAME DAY AFTER REPLACING WITH ANOTHER CANNULA. NO PATIENT IMPACT WAS REPORTED.