inforMED
MalfunctionBWN

LEG HOLDER

Received Mar 6, 2024 · Event occurred Feb 23, 2024

Report 8010652-2024-00032 · MDR key 18844140

Device

Generic name

Table And Attachments, Operating-room

Manufacturer

Maquet Gmbh

Model number

100380A0

Catalog number

100380A0

Product problems

  • Component Missing
  • Detachment of Device or Device Component
  • Component Missing
  • Detachment of Device or Device Component

Patient

NA · Unknown

  • No Clinical Signs, Symptoms or Conditions
  • No Clinical Signs, Symptoms or Conditions

Narrative

Additional Manufacturer Narrative

ADDITIONAL INFORMATION WILL BE PROVIDED FOLLOWING THE CONCLUSION OF THE INVESTIGATION. INITIAL REPORTER: (B)(6). E1H EVENT SITE POSTAL CODE: (B)(6). E1I EVENT SITE TELEPHONE: +(B)(6).

Description of Event or Problem

ON 23RD FEBRUARY 2024, GETINGE BECAME AWARE OF AN ISSUE WITH ONE OF OUR ACCESSORIES - 100380A0 - LEG HOLDER. AS IT WAS STATED, ALL FOUR PAN HEAD SCREWS ON THE SHOE JOINT TAPING OF THE LEG HOLDER WERE FOUND TO BE MISSING ON BOTH SIDES. BOOT SECURING PLATE HAD BECOME DETACHED FROM ASSEMBLY WHEN THE STAFF PICKED THE DEVICE TO MOVE IT. THERE WAS NO INJURY REPORTED, HOWEVER, WE DECIDED TO REPORT THE ISSUE BASED ON THE POTENTIAL FOR SERIOUS INJURY IF THE SITUATION, NAMELY THE USE OF A LEG HOLDER WITH MISSING SCREWS DURING SURGERY WHICH COULD RESULT IN UNINTENDED CHANGE IN PATIENT POSITION OR PATIENT'S FALL, WAS TO OCCUR.

Additional Manufacturer Narrative

GETINGE BECAME AWARE OF AN ISSUE WITH ONE OF OUR ACCESSORIES - 100380A0 - LEG HOLDER. AS IT WAS STATED, ALL FOUR PAN HEAD SCREWS ON THE SHOE JOINT TAPING OF THE LEG HOLDER WERE FOUND TO BE MISSING ON BOTH SIDES. THE BOOT SECURING PLATE HAD BECOME DETACHED FROM THE ASSEMBLY WHEN THE STAFF PICKED THE DEVICE TO MOVE IT. THERE WAS NO INJURY REPORTED, HOWEVER, WE DECIDED TO REPORT THE ISSUE BASED ON THE POTENTIAL FOR SERIOUS INJURY IF THE SITUATION, NAMELY THE USE OF A LEG HOLDER WITH MISSING SCREWS DURING SURGERY WHICH COULD RESULT IN AN UNINTENDED CHANGE IN PATIENT POSITION OR PATIENT'S FALL, WAS TO OCCUR. IT WAS ESTABLISHED THAT WHEN THE EVENT OCCURRED, THE DEVICE FAILED TO MEET ITS SPECIFICATION AND IN THIS WAY, THE DEVICE CONTRIBUTED TO THE EVENT. THE DEVICE WAS NOT BEING USED FOR THE PATIENT¿S TREATMENT WHEN THE EVENT TOOK PLACE. A REVIEW OF THE RECEIVED CUSTOMER PRODUCT COMPLAINTS REVEALED THAT THERE WERE NO INJURIES TO A USER NOR TO A PATIENT OR OPERATOR WHEN THIS PARTICULAR MALFUNCTION OCCURRED. THE ROOT CAUSE EVALUATION WAS PERFORMED. IT BECAME OBVIOUS THAT 4 SCREWS CONNECTING THE INTERFACE PLATE TO THE CLAMPING JOINT WERE NOT FITTED TO THE LEG HOLDER. THIS WAS NOT NOTICED DURING ASSEMBLY AND THE FINAL INSPECTION. IN ADDITION, THE PLATE IS PROVIDED WITH DOWEL PINS, WHICH WERE FITTED. HOWEVER, IF THE FITS ARE IN THE UPPER TOLERANCE RANGE AND THE FOUR LOCKING SCREWS ARE NOT FITTED, THE INTERFACE PLATE WILL DETACH FROM THE CLAMPING JOINT AS SOON AS IT IS LOADED. IT WAS CONCLUDED THAT THE ISSUE WAS CAUSED DUE TO HUMAN ERROR AND INSUFFICIENT QUALITY INSPECTION DURING ASSEMBLY. FIELD ACTION 2023-016 AND CAPA 2023-016 WERE INITIATED TO ADDRESS THE REPORTED ISSUE. THE CUSTOMERS WERE INFORMED ABOUT THE ISSUE VIA FIELD SAFETY NOTICE. THE SERVICE TECHNICIANS WERE INFORMED TO CHECK THE DEVICES AT THE CUSTOMER SITES AND PERFORM NECESSARY ACTIONS. IF MISSING SCREWS ARE DETECTED, THE SCREWS WILL BE MOUNTED BY A TECHNICIAN. IN SUMMARY AND AS A RESULT OF THE ROOT CAUSE EVALUATION, IT CAN BE CONCLUDED THAT THE REPORTED ISSUE, NAMELY THE LEG HOLDER BREAKING DUE TO THE MISSING SCREWS, WHICH COULD LEAD TO THE LEG OF THE PATIENT FALLING DOWN AND RESULT OF NERVE OVERSTRETCHING, WAS CAUSED BY THE MANUFACTURING ERROR. PREVIOUS D4 CATALOG #: 100380A0; CORRECTED D4 CATALOG #: N/A. PREVIOUS D4 SERIAL #: (B)(6); CORRECTED D4 SERIAL #: (B)(6). PREVIOUS D4 UNIQUE IDENTIFIER (UDI) #: N/A; CORRECTED D4 UNIQUE IDENTIFIER (UDI) #: (B)(4). PREVIOUS H4 DEVICE MANUFACTURE DATE: 01/01/2024; CORRECTED H4 DEVICE MANUFACTURE DATE: 12/15/2023.

Description of Event or Problem

MANUFACTURER'S REFERENCE NUMBER (B)(4).

Remedial action

  • Repair