inforMED
MalfunctionJEQ

ORALBPWRRCHGTOOTHBRUSHHANDLE3710

Received Jun 7, 2023

Report 3000302531-2023-00235 · MDR key 17080012

Device

Generic name

Toothbrush, Powered - Jeq

Model number

3710

Lot number

2RF22730817 105

Product problems

  • No Apparent Adverse Event
  • No Apparent Adverse Event

Patient

Unknown

  • No Clinical Signs, Symptoms or Conditions
  • No Clinical Signs, Symptoms or Conditions

Narrative

Description of Event or Problem

TOOTHBRUSH STARTED TO SMOKE. HEATING UP TO THE POINT OF BURNING OR SMELLING OF SMOKE - ORAL-B [DEVICE CATCHING FIRE]. CASE NARRATIVE: CONSUMER VIA PHONE STATED THAT THEIR ORAL-B TOOTHBRUSH STARTED TO SMOKE. IT STARTED SMELLING LIKE SMOKE AND BURNING AFTER A WHILE OF USE. NO INJURY WAS REPORTED.

Additional Manufacturer Narrative

PRODUCT RETURN WAS REQUESTED OR ITS IN TRANSPORT. EVALUATION WILL OCCUR UPON RECEIPT OF PRODUCT RETURN.

Additional Manufacturer Narrative

02-AUG-2023 PRODUCT INVESTIGATION RESULTS: COMPLAINED PRODUCT RECEIVED - USER HANDLING WAS IDENTIFIED AS ROOT CAUSE FOR THE COMPLAINT.

Description of Event or Problem

TOOTHBRUSH STARTED TO SMOKE...HEATING UP TO THE POINT OF BURNING OR SMELLING OF SMOKE - ORAL-B [DEVICE CATCHING FIRE]. CASE NARRATIVE: CONSUMER VIA PHONE STATED THAT THEIR ORAL-B TOOTHBRUSH STARTED TO SMOKE. IT STARTED SMELLING LIKE SMOKE AND BURNING AFTER A WHILE OF USE. NO INJURY WAS REPORTED. 26-JUN-2023 CASE UPDATE: THE SUSPECT PRODUCT LOT WAS 2RF22730817 105. NO INJURY WAS REPORTED.