POLARSTEM STEM STD TI/HA 1 NON-CEM
Received Feb 1, 2023 · Event occurred Dec 31, 2019
Report 9613369-2023-00102 · MDR key 16278128
Device
Generic name
Prosthesis, Hip, Semi-constrained, Metal/polymer, Uncemented
Manufacturer
Smith & Nephew Orthopaedics AgModel number
75100464Catalog number
75100464
Lot number
B1918450
Product problems
- Adverse Event Without Identified Device or Use Problem
- Adverse Event Without Identified Device or Use Problem
Patient
73 YR · Female
- Bone Fracture(s)
- Bone Fracture(s)
Narrative
Description of Event or Problem
IT WAS REPORTED THAT, AFTER A LEFT THR INDEX SURGERY PERFORMED ON (B)(6) 2019 TO ADDRESS OSTEOARTHRITIS SYMPTOMS, THE PATIENT PRESENTED A PERI-PROSTHETIC FRACTURE THAT MADE NECESSARY A REVISION SURGERY ON (B)(6) 2019. DURING THIS PROCEDURE, THE FEMORAL HEAD AND FEMORAL STEM WERE EXPLANTED. THIS INFORMATION WAS PROVIDED BY THE NATIONAL JOINT REGISTRY OF THE UNITED KINGDOM, AS PART OF A RETROSPECTIVE DATA COLLECTION OF PATIENTS WHO UNDERWENT A PRIMARY THR SURGERY WITH A HIP PROSTHESIS CONSTRUCT THAT INCLUDED A POLARSTEM STEM WITH AN R3 ACETABULAR CUP AND THAT REQUIRED A REVISION SURGERY DUE TO SPECIFIC REASONS. AS SUCH, NO FURTHER INFORMATION WILL BE AVAILABLE.
Additional Manufacturer Narrative
INTERNAL REFERENCE NUMBER: (B)(4). ROI: THIS COMPLAINT WAS OPENED BY SMITH+NEPHEW TO DOCUMENT A PATIENT COMPLICATION IDENTIFIED THROUGH A REVIEW OF THE NATIONAL JOINT REGISTRY FROM UNITED KINGDOM THAT INCLUDES REFERENCE TO THE USE OF A SMITH+NEPHEW PRODUCT. THE REPORTED ISSUE(S) RELATE TO KNOWN INHERENT PROCEDURAL RISKS THAT ARE APPROPRIATELY DOCUMENTED IN OUR RISK FILES. SMITH+NEPHEW WILL CONTINUE TO MONITOR TRENDS IN ACCORDANCE WITH OUR POST-MARKET SURVEILLANCE PROCESS AND TAKE NECESSARY ACTION AS REQUIRED IF ANTICIPATED SEVERITY AND/OR OCCURRENCE RATES ARE EXCEEDED. SMITH+NEPHEW HAS NO REASON TO SUSPECT THAT THE PRODUCT FAILED TO MEET ANY SPECIFICATIONS AT THE TIME OF MANUFACTURE. BASED ON OUR REVIEW OF ALL CURRENTLY AVAILABLE INFORMATION, WE ARE UNABLE TO CONFIRM A RELATIONSHIP BETWEEN THE REPORTED EVENT AND THE DEVICE OR IDENTIFY A DEFINITIVE ROOT CAUSE. HOWEVER, AS THE USE OF OUR PRODUCT CANNOT BE EXCLUDED AS A POTENTIAL CAUSE OR CONTRIBUTORY FACTOR TO THE REPORTED ISSUE, WE ARE CONSERVATIVELY SUBMITTING THIS REPORT IN ACCORDANCE WITH APPLICABLE REGULATIONS. IF ADDITIONAL INFORMATION BECOMES AVAILABLE THAT ALTERS THE CONCLUSIONS OF THIS REPORT, A FOLLOW-UP REPORT WILL BE SUBMITTED AS REQUIRED.