InjuryFBQ

SEALING UNIT F/10/12MM TROCARS W.REDUCER

Received May 11, 2022 · Event occurred Mar 14, 2022

Report 2916714-2022-00050 · MDR key 14365809

Device

Generic name

Access / Trocars

Manufacturer

Aesculap Ag

Model number

EK083P

Catalog number

EK083P

Product problems

  • Device Damaged by Another Device
  • Device Damaged by Another Device

Patient

Unknown

  • No Clinical Signs, Symptoms or Conditions
  • No Clinical Signs, Symptoms or Conditions

Narrative

Description of Event or Problem

IT WAS REPORTED TO AESCULAP INC. THAT A SEALING UNIT F/10/12MM TROCARS W.REDUCER (PART # EK083P) WAS USED DURING A PROCEDURE PERFORMED ON (B)(6) 2022. ACCORDING TO THE COMPLAINANT, THE INTERNAL PORT FELL OUT INTO THE PATIENT. IT WAS NOTED THAT EVEN AFTER "WETTING" THE APPLIERS (NON-AESCULAP PRODUCT: LARGE ENDOSCOPIC LIGATING CLIP APPLIERS), THE DEVICE DID NOT GO SMOOTHLY IN AND OUT OF THE 12 MILLIMETER (MM) PORT. AN ADDITIONAL MEDICAL INTERVENTION WAS NECESSARY. THE COMPLAINT DEVICE WAS NOT RETURNED TO THE MANUFACTURER FOR EVALUATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE EVENT. THE ADVERSE EVENT IS FILED UNDER AIC REFERENCE (B)(4).

Additional Manufacturer Narrative

MANUFACTURING SITE EVALUATION: INVESTIGATION ON-GOING. SHOULD RELEVANT ADDITIONAL INFORMATION / INVESTIGATION RESULTS BECOME AVAILABLE, A SUPPLEMENTAL MEDWATCH REPORT WILL BE SUBMITTED.

Additional Manufacturer Narrative

INVESTIGATION RESULTS: AS OF THE DATE OF THIS REPORT THE COMPLAINT PRODUCT WAS NOT PROVIDED FOR INVESTIGATION. THEREFORE, A THOROUGH INVESTIGATION IS NOT POSSIBLE. BASED UPON THE PROVIDED PICTURE, IT COULD BE DETECTED THAT THE SEALING OF THE COMPLAINT SAMPLE WAS TORN AND THE CROSS SLOT VALVE 10-12 MM WAS FOUND IN SITU. BATCH HISTORY REVIEW: DUE TO THE FACT THAT NEITHER AN ARTICLE NUMBER NOR A LOT NUMBER WAS PROVIDED, A REVIEW OF THE DEVICE HISTORY RECORDS MUST REMAIN INCOMPLETE. EXPLANATION AND RATIONALE: ACCORDING TO THE APPLICABLE INSTRUCTIONS FOR USE (IFU), THE FOLLOWING POINTS MUST BE OBSERVED: TO PREVENT DAMAGE TO THE SEALING ELEMENT, APPLY APPROPRIATE CARE WHEN INSERTING ANY INSTRUMENTS IF POSSIBLE, INSERT INSTRUMENTS IN THEIR CLOSED POSITION, STRAIGHT AND CENTRAL THROUGH THE SEALING ELEMENT CONCLUSION AND MEASURES / PREVENTIVE MEASURES: BASED UPON THE INVESTIGATION RESULTS A CLEAR ROOT CAUSE CONCLUSION CANNOT BE DRAWN. THERE IS NO INDICATION FOR A MATERIAL-, MANUFACTURING- OR DESIGN-RELATED FAILURE. IN THE EVENT THAT THE COMPLAINT PRODUCT WILL BE PROVIDED FOR INVESTIGATION IN THE FUTURE, AN UPDATE OF THIS REPORT WILL BE PROVIDED UNSOLICITED. BASED UPON THE INVESTIGATIONS RESULTS A CAPA IS NOT NECESSARY.

Description of Event or Problem

NO CHANGES REQUIRED.