inforMED
InjuryMSB

CELSIOR (ORGAN PRESERVATION SOLUTION) SOLUTION FOR ORGAN PRESERVATION

Received May 1, 2009 · Event occurred Feb 12, 2005

Report 2950168-2009-00005 · MDR key 1374452

Device

Generic name

Organ Preservation Solution

Model number

NA

Catalog number

NA

Lot number

UNK

Product problems

  • Unknown (for use when the device problem is not known)

Patient

28 YR

  • Liver Damage/Dysfunction
  • Stenosis
  • Surgical procedure
  • Treatment with medication(s)

Narrative

Description of Event or Problem

SEVERE LIVER FAILURE [HEPATIC FAILURE]. HEPATIC ARTERY STENOSIS [HEPATIC ARTERY STENOSIS]. PORTAL VEIN STENOSIS [PORTAL VEIN STENOSIS]. CASE DESCRIPTION: REPORT RECEIVED ON 06 MARCH 2009 FROM AN UNPUBLISHED LITERATURE REPORT. THIS IS A LITERATURE REPORT ENTITLED, "CELSIOR PRESERVATION FLUID IN LIVE TRANSPLANTATION: RESULTS OF PROSPECTIVE, MULTICENTER STUDY. GRANDADAM S ET AL." THE LITERATURE DESCRIBES A ONE-YEAR, PROSPECTIVE, CENTER, STUDY TO ASSESS THE RESULTS FROM A TOTAL PATIENTS WHO RECEIVED DONOR LIVERS FOR WHICH RECOVERY WAS PERFORMED USING CELSIOR SOLUTION. DATA COMPARED LIVER ALLOGRAFT OUTCOMES FOLLOWING GRAFT RECOVERY WITH CELSIOR PRESERVATION FLUIDS. THE ARTICLE DESCRIBES PATIENTS ACROSS TRANSPLANT CENTERS IN OTHER COUNTRY THAT EXPERIENCED ADVERSE EVENTS WITH CELSIOR. THE MALE LIVER TRANSPLANT PATIENT RECEIVED HIS SECOND LIVER TRANSPLANT IN EARLY 2005. THE PATIENT'S MEDICAL HISTORY WAS NOT PROVIDED. ON THE FOLLOWING MONTH, 20 DAYS AFTER CELSIOR EXPOSURE, THE PATIENT EXPERIENCED SEVERE LIVER FAILURE, HEPATIC ARTERY STENOSIS, AND HEPATIC PORTAL VEIN STENOSIS. DONOR RECOVERY WAS PERFORMED BY THE CONVENTIONAL TECHNIQUE. DONOR LIVERS WERE PERFUSED IN SITU BY GRAVITY WITH CELSIOR SOLUTION AT 4 DEGREES C. WHEN ONLY AORTIC ANNULATION WAS USED, 4L CELSIOR SOLUTION WAS RAPIDLY PERFUSED THROUGH THE AORTA AT THE BEGINNING OF THE PROCEDURE. WHERE BOTH AORTIC AND MESENTERIC VEIN CANNULATION WERE USED, 2 L WAS PERFUSED THROUGH EACH ROUTE. A FURTHER 1L WAS PERFUSED SLOWLY DURING THE RECOVERY PROCEDURE. THE BILIARY TRACT WAS RINSED EX SITU WITH AN ADDITIONAL 100ML. DURING STORAGE, THE LIVER WAS COMPLETELY IMMERSED IN AT LEAST 1L SOLUTION AND MAINTAINED AT 4 DEGREES C UNTIL TRANSPLANTATION. TRANSPLANTATION WAS PERFORMED BY THE PIGGYBACK TECHNIQUE I.E. PRESERVING THE RETROHEPATIC VENA CAVA. PORTAL, ARTERIAL, AND BILIARY ANASTOMOSES WERE PERFORMED ACCORDING TO THE LOCAL EXPERTISE OF EACH CENTER. IMMEDIATELY PRIOR TO REVASCULARIZATION, THE LIVER WAS WASHED WITH 500 ML OF 4% HUMAN ALBUMIN SOLUTION AT 4 DEGREES C VIA THE PORTAL VEIN. THE REWARMING PERIOD WAS DEFINED AS THE TIME WHICH ELAPSED BETWEEN PORTAL VEIN DECLAMPING AND ARTERIAL DECLAMPING. THE PATIENT'S OUT COME AND THE INTENSITY OF THE EVENTS WERE NOT PROVIDED. CONCOMITANT MEDICATIONS AT THE TIME OF THE EVENTS INCLUDED PREDNISONE, FK 506 (TACROLIMUS, MYCOPHENOLATE MOFETIL, ACETAMINOPHEN, FUROSEMIDE, PIPERACILLINE, LEVOFLOXACINE, AND FLUCONAZOLE. IT WAS THE OPINION OF THE AUTHORS THAT THE EVENTS WERE POSSIBLY RELATED TO CELSIOR.

Additional Manufacturer Narrative

MANUFACTURER'S COMMENT: THE ACCOMPANYING UNPUBLISHED LITERATURE ARTICLE SUMMARIZES THE RESULTS OF A CELSIOR STUDY CONDUCTED BY A GROUP OF INVESTIGATORS INDEPENDENT OF GENZYME. UPON REQUEST FROM GENZYME, THE AUTHORS OF THE LITERATURE ARTICLE PROVIDED A TABULAR LISTING OF CELSIOR ADVERSE EVENTS THAT PROVIDED INDIVIDUAL PATIENT IDENTIFIERS. SEVEN OF THE CASES DESCRIBED HAD PREVIOUSLY BEEN REPORTED TO GENZYME DURING THE COURSE OF THE STUDY. THE AUTHORS CONCLUDED THAT THIS PROSPECTIVE, MULTICENTER STUDY SUGGESTS THAT LIVER PRESERVATION WITH CELSIOR IS EFFICIENT AND SAFE. THE BENEFIT-RISK RELATIONSHIP OF CELSIOR IS NOT AFFECTED BY THIS REPORT. JOURNAL: UNPUBLISHED LITERATURE. AUTHOR: GRANDADAM ET AL. TITLE: CELSIOR PRESERVATION FLUID IN LIVER TRANSPLANTATION: RESULTS OF A PROSPECTIVE, MULTICENTER STUDY.