inforMED
MalfunctionILK

BRUNO ELECTRA-RIDE II

Received Oct 12, 2006 · Event occurred Sep 11, 2006

Report 2131358-2006-00009 · MDR key 1349503

Device

Generic name

Inclined Stairway Elevator

Model number

SRE-2000

Product problems

  • Break

Patient

UNK

  • Fall
  • Laceration(s)

Narrative

Description of Event or Problem

USER WAS RIDING STAIRLIFT, WHEN THE SEAT BROKE IN SUCH A WAY THAT THE USER FELL OFF THE STAIRLIFT SEAT ON TO THE FLOOR. THE USER RECEIVED A CUT ON HIS LEG. BRUNO DOES NOT KNOW IF THE USER RECEIVED MEDICAL ATTENTION, OR NOT.

Additional Manufacturer Narrative

CONCLUSION: REVIEWING THE RETURNED UNIT AND THE MODEL SRE-2000 CUSTOMER COMPLAINT RECORDS - I FEEL THAT THIS IS AN ISOLATED FAILURE CAUSED BY JOINT FAILURE WHOSE ROOT CAUSE IS POOR WELD PENETRATION, AS THE OPERATOR FOLLOWED THE PART CONTOUR.

Remedial action

  • Replace