RETCAM ENVISION, SYSTEM WITH FA
Received Dec 6, 2021 · Event occurred Nov 15, 2021
Report 9612330-2021-00035 · MDR key 12932292
Device
Generic name
Retcam Envision, System With Fa
Manufacturer
Natus Medical IncorporatedModel number
61-000300Catalog number
61-000300
Product problems
- No Display/Image
- Misfocusing
- No Display/Image
- Misfocusing
Patient
1 YR · Male
- No Clinical Signs, Symptoms or Conditions
- No Clinical Signs, Symptoms or Conditions
Narrative
Additional Manufacturer Narrative
FOLLOW UP REPORT 001 REF TO NATUS COMPLAINT#: (B)(4). THE DISTRIBUTOR PROVIDED A RESPONSE TO THE QUESTIONNAIRE. THE DISTRIBUTOR REPORTS THE PATIENT WAS A 1 YEAR OLD MALE, WEIGHING 10 KG. UPON FOLLOW UP, THE PHOTOS ARE MISLEADING AS THEY (ARTIFACTS) LOOK LIKE ACTIVE TUMORS IN PATIENTS WITH RETINOBLASTOMA. WHILE THEY ARE IN FACT JUST ARTIFACT THAT CANNOT BE DELETED FROM THE SCREEN. IN CASE A NEW TUMOR WERE TO DEVELOP IN THE FUTURE, AND THE PATIENT'S FAMILY HAD THE ARTIFACT PHOTOS, THEY CAN CLAIM THAT THE TUMOR WAS THERE PREVIOUSLY AND NOT TREATED WELL, WHICH IS A BIG MEDICAL LEGAL ISSUE. PRODUCT EXAMINATION AND FUNCTIONAL TESTING: PRODUCT WILL NOT BE EVALUATED, AS IT DID NOT MALFUNCTION. THE ISSUE MENTIONED BY THE DOCTOR REGARDING BEING UNABLE TO GET GOOD OR FAIR RESOLUTION, EVEN IF THE PUPIL IS FULLY DILATED, ON A PATIENT WHO HAS DARK SKIN IS NOT A PRODUCT MALFUNCTION. THIS RELATED TO CONDITIONS THAT MY BE OBSERVED IN CHALLENGING SEGMENTS OF THE PATIENT POPULATION WHO HAVE DARK SKIN / RETINAS. REDUCED ILLUMINATION OF THE RETINA, IF THE EYE PUPIL IS NOT FULLY DILATED, AND INCREASED ABSORPTION OF LIGHTS BY THE DARK RETINA CAUSES A LOSS OF IMAGE CONTRACTS AND RELATIVELY INCREASED SIGNALS TO NOISE DUE TO THE SCATTER, WHICH CAN REDUCE OBSERVER TASK DETECTION PERFORMANCE, AND POSSIBLY IS NOT EXACTLY THE SAME AS THE PREVIOUS WIDE ANGLE SYSTEMS DUE TO THE CHANGE IN THE DESIGN. FOR THE DOCTOR'S REPORT THAT THE LENS IS ALWAYS LOOSE. LEAD RISK MANAGEMENT ENGINEER, ADVISED THAT THIS IS NOT A MALFUNCTION. THE LENS IS DESIGNED TO BE ATTACHED/DETACHED AND THE ISSUE DESCRIBED BY THE DOCTOR MAY BE WITHIN THE FIT TOLERANCES. THERE ARE NO CAPA'S RELATED TO THIS ISSUE AND THIS COMPLAINT DOES NOT IDENTIFY A DEFICIENCY IN THE PRODUCT DESIGN AND THEREFOR A CAPA IS NOT REQUIRED. PER QMS-004442 COMPLAINT HISTORIES ARE REVIEWED ROUTINELY PER QUALITY SYSTEM REQUIREMENTS AND ANY COMPLAINT TRENDS ARE ASSESSED AND DOCUMENTED AS PART OF THESE REVIEWS. NO COMPLAINT TRENDS HAVE BEEN IDENTIFIED. THE DEVICE HISTORY RECORD WAS REVIEWED AND NO RELATED FAULTS/ISSUE FOUND. THE FAILURE WAS NOT CONFIRMED. UNABLE TO CONFIRM/REPRODUCE REPORTED ISSUE. THIS COMPLAINT COULD NOT BE VERIFIED, MONITOR FOR FUTURE OCCURRENCE. LOW SAFETY RISK OF HARM, INDIVIDUAL COMPLAINT RELATED TO ISSUE STATED. COMPLAINT WILL BE INCLUDED IN TRENDING DATA FOR FURTHER REVIEW AND INVESTIGATION IF NEEDED.
Description of Event or Problem
PART: 61-000300 RETCAM ENVISION, SYSTEM WITH FA - WE HAVE A COMPLAINT FROM THE DOCTOR ABOUT THE INSTABILITY OF THE LENS IN THE CAMERA AND THE MOVEMENT. THE DOCTOR IS UNSATISFIED WITH THE IMAGE QUALITY AND SOMETIMES GAVE HIM WRONG DIAGNOSE. NO INJURIES REPORTED.
Additional Manufacturer Narrative
INITIAL REPORT REF TO NATUS COMPLAINT# (B)(4). INFORMATION PROVIDED SHOWS THE DOCTOR IS UNSATISFIED WITH THE IMAGE QUALITY AND SOMETIMES GIVES THEM THE WRONG DIAGNOSIS. WHEN THE DOCTOR STARTED WORKING WITH THE NEW RETCAM SYSTEM, THE FIRST IMAGES WERE AMAZING. THE IMAGES HAD EXCELLENT RESOLUTION AND AN AMAZING VIEW FOR THE PERIPHERY AS NEEDED. HOWEVER, THIS IS NOT THE CASE FOR ALL PATIENTS. PER THE DOCTOR, "WE COULD GET SUCH AMAZING IMAGES IF AND ONLY IF THE PATIENT WAS NOT DARK IN COLOR, AND THE PUPIL WAS FULLY DILATED." THE DOCTOR PROVIDED EXAMPLES OF WHAT THEY ARE SEEING. FOR ONE OF THE IMAGES, THE DOCTOR REPORTS THAT THE CHILD HAD THEIR PUPIL "SEMI FULLY DILATED" AND THEY COULD NOT GET RID OF THE WHITE ARTIFACTS. FOR THE DOCTOR, WHO IS AN EYE TUMOR SPECIALIST, THE ARTIFACTS LOOK LIKE ACTIVE NEW TUMORS. WHEN IN FACT, IT'S JUST ARTIFACTS. PER 18-000623 REV 05 RETCAM ENVISION RISK ANALYSIS: HAZARD ID 12.23 . CAUSE: IMAGE ARTIFACT(S) THAT MIMICS PATHOLOGY WHEN PERFORMING CLINICAL DETECTION TASK, SUCH AS DUE TO LENS OPTICAL SURFACE CONTAMINATION. EFFECTS (HARM): REDUCED OBSERVER PERFORMANCE BY POTENTIAL REDUCTION OF SPECIFICITY (INCREASED FALSE POSITIVE), REQUIRING UNNECESSARY ADDITIONAL DIAGNOSTIC PROCEDURES OR HEALTH CONCERNS. RESIDUAL RISK IS 3 (LOW) AND ACCEPTABLE. THE HAZARDS IDENTIFIED HAVE RBA RATING OF LOW AND ARE DEEMED BROADLY ACCEPTABLE. THESE RISKS HAVE BEEN REVIEWED TO DETERMINE IF ANY FURTHER CONTROL MEASURES MAY BE IMPLEMENTED SO AS TO FURTHER REDUCE THE RISK AS FAR AS POSSIBLE. RISK OUTWEIGHED BY BENEFIT OF USE OF DEVICE. INSTALL DATE: SEPTEMBER 21, 2021 FURTHER INVESTIGATION TO BE CARRIED OUT ON THE AFFECTED PART.
Description of Event or Problem
PART 61-000300 RETCAM ENVISION, SYSTEM WITH FA - WE HAVE A COMPLAINT FROM THE DOCTOR ABOUT THE INSTABILITY OF THE LENS IN THE CAMERA AND THE MOVEMENT. THE DOCTOR IS UNSATISFIED WITH THE IMAGE QUALITY AND SOMETIMES GAVE HIM WRONG DIAGNOSE. NO INJURIES REPORTED.