LIGHT-GUIDE CABLE, 2.8 MM, 3 M, CF TYPE

Received Feb 24, 2021 · Event occurred Feb 10, 2021

Report 9610773-2021-00081 · MDR key 11371886

Device

Generic name

Light Guide And Accessories

Model number

WA03300A

Catalog number

WA03300A

Lot number

201W0001

Product problems

  • Adverse Event Without Identified Device or Use Problem
  • Adverse Event Without Identified Device or Use Problem

Patient

Not reported

  • Burn(s)
  • Blister
  • Burn(s)
  • Blister

Narrative

Additional Manufacturer Narrative

THE SUSPECT MEDICAL DEVICE HAS NOT YET BEEN RETURNED TO OLYMPUS FOR EVALUATION/INVESTIGATION. THEREFORE, THE EXACT CAUSE OF THE PATIENT¿S OUTCOME AND THE REPORTED PHENOMENON COULD NOT BE DETERMINED AND IS BEING JUDGED AS UNKNOWN. HOWEVER, IF THE SUSPECT MEDICAL DEVICE IS RETURNED FOR EVALUATION/INVESTIGATION OR ADDITIONAL SIGNIFICANT INFORMATION BECOMES AVAILABLE, THIS REPORT WILL BE UPDATED.

Description of Event or Problem

OLYMPUS WAS INFORMED THAT WHEN THE DRAPE WAS REMOVED FROM THE PATIENT AFTER A SUCCESSFULLY COMPLETED THERAPEUTIC TRANSURETHRAL LITHOTRIPSY (TUL) PROCEDURE, IT WAS NOTICED THAT THE PATIENT HAD SUSTAINED A BURN INJURY OF APPROX. 22.5-23.5 MM ON ONE LEG. IT IS ASSUMED THAT THE BURN OCCURRED WHEN THE LIGHT-GUIDE CABLE WAS SHORTLY PLACED ON THE PATIENT AFTER IT HAD BEEN REMOVED FROM THE SCOPE. NO FURTHER INFORMATION WAS PROVIDED.

Additional Manufacturer Narrative

DEVICE EVALUATION: THE SUSPECT MEDICAL DEVICE WAS NOT RETURNED TO OLYMPUS FOR EVALUATION/INVESTIGATION. THEREFORE, THE EXACT CAUSE OF THE PATIENT'S OUTCOME AND THE REPORTED PHENOMENON COULD NOT BE DETERMINED AND IS BEING JUDGED AS UNKNOWN. HOWEVER, IN THE CASE AT HAND, THERE WAS NO REPORT OF A MALFUNCTION OF THE AFFECTED DEVICE AND, THEREFORE, IT CAN BE ASSUMED THAT THE LIGHT-GUIDE CABLE WAS IN STANDARD CONDITION AND THE BURN INJURY MOST LIKELY RESULTED FROM THE USER PLACING THE CABLE ON THE PATIENT'S LEG AFTER DISCONNECTING IT FROM THE TELESCOPE. WHEN THE CABLE IS USED IN A PROCEDURE, HEAT BUILDS UP IN THE CABLE. THIS IS CLEARLY STATED AS A WARNING IN THE INSTRUCTIONS FOR USE. HOWEVER, A MATERIAL OR QUALITY PROBLEM CAN BE EXCLUDED SINCE A MANUFACTURING AND QUALITY CONTROL REVIEW WAS PERFORMED FOR THE AFFECTED LOT NUMBER OF THE LIGHT-GUIDE CABLE WITHOUT SHOWING ANY ABNORMALITIES. THE CASE WILL BE CLOSED FROM OLYMPUS SIDE WITH NO FURTHER ACTIONS. THE REPORTED EVENT/INCIDENT WILL BE RECORDED FOR TRENDING AND SURVEILLANCE PURPOSES AND THE USER WILL BE INFORMED ABOUT THE INVESTIGATION RESULTS.