inforMED
MalfunctionGDZ

LONG SCALPEL HANDLE

Received May 12, 2020

Report 2939274-2020-02316 · MDR key 10049357

Device

Generic name

Handle, Scalpel

Model number

03.010.491

Catalog number

03.010.491

Lot number

7927771

Product problems

  • Break
  • Break

Patient

Not reported

  • No Patient Involvement
  • No Patient Involvement

Narrative

Additional Manufacturer Narrative

DEPUY SYNTHES IS SUBMITTING THIS REPORT PURSUANT TO THE PROVISIONS OF 21 CFR, PART 803. THIS REPORT MAY BE BASED ON INFORMATION WHICH DEPUY SYNTHES HAS NOT BEEN ABLE TO INVESTIGATE OR VERIFY PRIOR TO THE REQUIRED REPORTING DATE. THIS REPORT DOES NOT REFLECT A CONCLUSION BY FDA, DEPUY SYNTHES OR ITS EMPLOYEES THAT THE REPORT CONSTITUTES AN ADMISSION THAT THE DEVICE, DEPUY SYNTHES, OR ITS EMPLOYEES CAUSED OR CONTRIBUTED TO THE POTENTIAL EVENT DESCRIBED IN THIS REPORT. H3, H4, H6 INVESTIGATION SUMMARY. VISUAL INSPECTION: THE LONG SCALPEL HANDLE (P/N: 03.010.491, LOT NUMBER: 7927771) WAS RECEIVED AT US CQ. UPON VISUAL INSPECTION, IT WAS OBSERVED THAT THE SCALPEL TIP BROKE OFF OF THE COMPLAINT DEVICE. ADDITIONALLY, SCRATCHES WERE OBSERVED ON THE SCALPEL TIP AROUND THE BREAKING POINT. NO DAMAGE OR DEFECT WAS NOTED TO THE REMAINING FEATURES OR COMPONENTS OF THE RETURNED DEVICE. DEVICE FAILURE/DEFECT IDENTIFIED? YES. DIMENSIONAL INSPECTION: SPECIFIED DIMENSIONS: SCALPEL TIP WIDTH = 3.5 MM -0.01/- 0.03 MM. MEASURED DIMENSIONS: SCALPEL TIP WIDTH (BETWEEN WELD AND BREAK) = 3.49 MM, CONFORMING FURTHER DIMENSIONAL INSPECTION COULD NOT BE PERFORMED DUE TO DEVICE GEOMETRY. DOCUMENT/SPECIFICATION REVIEW: THE FOLLOWING DOCUMENT(S) WERE REVIEWED: SCALPEL ASSEMBLY, SCALPEL TIP, NO DESIGN ISSUES OR DISCREPANCIES WERE IDENTIFIED. COMPLAINT CONFIRMED? YES. INVESTIGATION CONCLUSION: THIS COMPLAINT WAS CONFIRMED AS THE SCALPEL TIP BROKE OFF OF THE COMPLAINT DEVICE. ADDITIONALLY, SCRATCHES WERE OBSERVED ON THE SCALPEL TIP AROUND THE BREAKING POINT. NO DEFINITIVE ROOT CAUSE COULD BE DETERMINED BASED ON THE PROVIDED INFORMATION, ALTHOUGH IT IS POSSIBLE THAT UNINTENDED FORCES APPLIED TO THE DEVICE COULD HAVE CONTRIBUTED TO THE COMPLAINT CONDITION. NO NEW, UNIQUE OR DIFFERENT PATIENT HARMS WERE IDENTIFIED AS A RESULT OF THIS EVALUATION. THERE WAS NO INDICATION THAT A DESIGN OR MANUFACTURING ISSUE CONTRIBUTED TO THE COMPLAINT. NO DESIGN ISSUES WERE OBSERVED DURING THE DOCUMENT/SPECIFICATION REVIEW. BASED ON THE INVESTIGATION FINDINGS, IT HAS BEEN DETERMINED THAT NO CORRECTIVE AND/OR PREVENTATIVE ACTION IS PROPOSED. ADDITIONAL MONITORING FOR ANY POTENTIAL SAFETY SIGNALS WILL BE CONDUCTED THROUGH COMPLAINT TRENDING AND OTHER POST MARKET SAFETY SURVEILLANCE ACTIVITIES. DEVICE HISTORY: PART #: 03.010.491, SYNTHES LOT NUMBER: 7927771, SUPPLIER LOT NUMBER: 7927771, RELEASE TO WAREHOUSE DATE: 17-JUN-2015, SUPPLIER: AVALIGN TECHNOLOGIES - NEMCOMED. NO NCRS WERE GENERATED DURING PRODUCTION. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Additional Manufacturer Narrative

(B)(6). THE DEVICE WAS RECEIVED, THE INVESTIGATION IS IN PROGRESS, NO CONCLUSION COULD BE DRAWN AT THE TIME OF FILING THIS REPORT. DEVICE WAS USED FOR TREATMENT, NOT DIAGNOSIS. IF INFORMATION IS OBTAINED THAT WAS NOT AVAILABLE FOR THE INITIAL MEDWATCH, A FOLLOW-UP MEDWATCH WILL BE FILED AS APPROPRIATE.

Description of Event or Problem

IT WAS REPORTED THAT ON AN UNKNOWN DATE, A BREAK ON THE TIP OF A LONG HANDLE SCALPEL OCCURRED DURING CLEANING AFTER USE. THERE WAS NO PATIENT INVOLVEMENT. THIS COMPLAINT INVOLVES ONE (1) DEVICE. THIS REPORT IS FOR ONE (1) LONG SCALPEL HANDLE. THIS IS REPORT 1 OF 1 FOR (B)(4).